Danfoss EVR 25 Servo-Operated Solenoid Valve
Overview
Danfoss EVR 25 is a servo-piston operated solenoid valve from Danfoss’s widely deployed EVR range, purpose-built for precise on/off control of refrigerant flow in liquid, suction, and hot gas lines. Used across commercial refrigeration and air conditioning systems worldwide, the EVR 25 pairs a robust brass valve body with an easy-to-service, clip-on coil design that allows technicians to service the coil and internal parts without removing the valve body from the pipeline — a detail that meaningfully reduces system downtime and refrigerant loss during maintenance.
As the official authorized partner and exclusive regional representative for Danfoss, Seven Star LLC proudly supplies the Danfoss EVR 25 and the full EVR solenoid valve range to customers across Oman and the wider GCC. Facility engineers and contracting teams in Muscat, Sohar, and Salalah rely on Seven Star LLC for genuine Danfoss valve bodies and coils, backed by manufacturer warranty and technical support suited to the region’s demanding cooling and process-refrigeration loads.
Operating Principle
The EVR 25 is a normally closed, servo-operated piston valve. When the coil is de-energized, the piston and valve plate are held closed against the valve seat by the differential pressure between the inlet and outlet sides, combined with the force of a return spring and the weight of the piston assembly. This design keeps the valve reliably sealed with zero manual intervention whenever power is removed, which is an important safety and control characteristic for unattended refrigeration plant.
When the coil is energized, the pilot orifice located in the valve cover opens, relieving pressure on the spring side of the piston. The resulting pressure differential across the piston lifts it off the seat, opening the main valve to admit full flow. A minimum differential pressure of around 0.07 bar (1 psi) is required to open the valve and to keep it fully open during operation. Because the valve has no packing gland or stem seal exposed to the refrigerant path, there is no dynamic seal to wear out under cycling, which translates into a long, low-maintenance service life and a dependable shut-off with minimal risk of internal leakage past the seat.
Engineering Design of the Danfoss EVR 25
The Danfoss EVR 25 valve body is precision-machined brass, fitted with solder ODF connections sized 28 mm (1-1/8 in) or 35 mm (1-3/8 in), with a 25 mm port and Cv value of 12.0 gal/min, giving it the flow capacity to serve mid-to-large commercial liquid, suction, and hot gas circuits. Extended solder connections mean the valve body does not need to be dismantled during pipe soldering, protecting the internal seals and diaphragm from heat damage during installation — a practical advantage on retrofit and brownfield refrigeration jobs.
Above the valve body sits a clip-on coil, available in both AC (24–240 V, 50/60 Hz) and DC (12–220 V) versions, each interchangeable across the EVR body range without tools. AC coils are offered in junction box (NEMA 1/IP54) or conduit boss (NEMA 4/IP54) termination styles, while DC coils are rated to IP67 (NEMA 6) for wash-down or exposed outdoor installation. Class H insulated coil wire supports continuous duty across an ambient range of –40°C to +50°C, and the coil, armature, and pilot assembly can all be replaced as spare parts in the field without breaking the refrigerant circuit.
Key Features
The Danfoss EVR 25 delivers dependable refrigerant shut-off with a feature set built around service life and installation flexibility. Key characteristics of the Danfoss EVR 25 include:
- Servo-piston operation provides reliable, tight shut-off in liquid, suction, and hot gas refrigerant lines.
- Normally closed (NC) configuration with de-energized coil ensures fail-safe closure on power loss.
- Wide range of clip-on AC and DC coils, interchangeable without dismantling the valve body.
- Coil enclosure options up to IP67 (NEMA 6) support harsh, humid, or outdoor installation environments.
- Compatible with fluorinated refrigerants and most hydrocarbon refrigerants used in modern HVAC-R systems.
- Rated for media temperatures up to 105°C continuous, and up to 130°C during hot gas defrost cycles.
- Maximum working pressure of approximately 32 bar (460 psig) suits medium and high-pressure refrigeration circuits.
- Extended solder ODF connections allow pipe soldering without dismantling internal valve components.
Industrial Applications
The Danfoss EVR 25 solenoid valve is deployed throughout commercial and industrial refrigeration and air conditioning: cold storage warehouses, supermarket and hypermarket refrigeration racks, chiller and condensing unit liquid lines, hot gas defrost circuits, and central plant suction lines feeding multiple evaporators. Its mid-size flow capacity makes it a common choice for district cooling plant rooms, food and beverage cold chain facilities, and packaged chiller systems where reliable, fail-safe shut-off is required at each branch line.
As the officially authorized partner for Danfoss, Seven Star LLC distributes the EVR 25 and related refrigeration valve components to cold chain operators, HVAC contractors, and industrial refrigeration integrators across the Sultanate of Oman and the GCC, including projects in the Sohar and Salalah free zones. Regional customers in food processing, hospitality, and commercial building services depend on Seven Star LLC to supply genuine Danfoss valve bodies, coils, and spare parts with the local technical support needed to keep cooling plant running reliably through Oman’s peak-demand summer months.
Technical Specifications
Key technical data for the Danfoss EVR 25 servo-operated solenoid valve is summarized below; the Danfoss EVR 25 datasheet figures are listed for reference during system sizing.
| Parameter | Specification |
|---|---|
| Model | Danfoss EVR 25 |
| Valve Type | Servo-piston operated solenoid valve, normally closed (NC) |
| Connection | Solder ODF, 28 mm (1-1/8 in) or 35 mm (1-3/8 in) |
| Port Size | 25 mm (1 in) |
| Cv Value | 12.0 gal/min |
| Refrigerant Compatibility | Fluorinated refrigerants (R22, R134a, R404A, R507, etc.) and most hydrocarbons |
| Media Temperature Range | –40°C to +105°C (up to +130°C during defrost) |
| Maximum Working Pressure | ≈32 bar (460 psig) |
| Minimum Opening Differential Pressure | ≈0.07 bar (1 psi) |
| Coil Voltage (AC) | 24–240 V, 50/60 Hz |
| Coil Voltage (DC) | 12–220 V |
| Coil Enclosure | NEMA 1/2 (IP54) junction box or NEMA 4/6 (IP54–IP67) conduit/terminal box |
| Coil Insulation | Class H per IEC 85 |
| Ambient Temperature | –40°C to +50°C |
| Body Material | Brass |
| Approvals | UL listed (file MH 7648), LVD 73/23/EC compliant |
Request a Quote for Danfoss EVR 25 Servo-Operated Solenoid Valve
Contact Seven Star LLC to request a formal quotation for the Danfoss EVR 25 solenoid valve or any model across the EVR range — our team can confirm Danfoss EVR 25 lead times and regional stock availability on request. As the authorized partner for Danfoss in Oman and the GCC, Seven Star LLC maintains regional stock, provides technical datasheets on request, and connects customers directly with our instrumentation and refrigeration controls division for sizing support, coil selection, and project-specific configuration across cold storage, HVAC-R, and process cooling applications.
Related Products
- Dungs SV-D 505 Safety solenoid valve Nominal width Rp 1/2 – Rp 2