Brand:

SICK IMF18-12NPONC0S IP69K Inductive Sensor, 12 mm, PNP NC

Description

Why choose SICK IMF18-12NPONC0S

A normally-closed output has one engineering advantage: a failure in cable or supply looks the same to the controller as a target in front of the sensor, so the fault is detected immediately. The SICK IMF18-12NPONC0S (part number 1076667) offers that behaviour with a PNP stage in the rugged IMF18 housing, 12 mm non-flush range, and IP68/IP69K protection suitable for washdown.

Details of the NC output

The letter O in the code marks the normally-closed function. In use, the output conducts while no metal is in range and opens as the target enters the sensing field. The datasheet specifies PNP switching, continuous current up to 200 mA, a voltage drop up to 2 V and switching frequency of 1,000 Hz. Hysteresis is 3 to 20 percent and reproducibility up to 2 percent. The unit is protected against short circuits and power-up pulses.

  • Output function: NC, PNP, DC 3-wire
  • Temperature range minus 40 to plus 100 degrees Celsius
  • Visual adjustment indicator and resistance to cleaning agents
  • Gold-plated M12 contacts, V4A stainless nuts

IMF18-12NPONC0S data table

Parameter Value
Part number 1076667
Thread / design M18 x 1, 65 mm long, thread 39 mm
Installation Non-flush
Sn / Sa 12 mm / 9.72 mm
Supply 10 V DC to 30 V DC
Output PNP, normally closed, DC 3-wire
Switching frequency 1,000 Hz
Connection Male connector M12, 4-pin
Sensing face / nuts LCP / V4A stainless steel
Enclosure rating IP68, IP69K
Operating temperature Minus 40 to plus 100 C
Tightening torque Typically 90 Nm
Protection class / MTTFD III / 1,971 years

How IMF18-12NPONC0S differs from other IMF18 variants

The only change against the IMF18-12NNSNC0S is the output: PNP normally closed instead of NPN normally open. The IMF18-08BPSNC0S differs more: it is quasi-flush, 8 mm and has IO-Link. Order by polarity and logic first, then by range, because installing the wrong logic type inverts the machine signal and may only be noticed at the first start.

Applications

Conveyor guide monitoring, door and cover position checks on washdown machines, and valve end-position confirmation on hygienic process lines. Normally closed logic is popular where a missing signal must be treated as a fault, for example in interlock chains.

Selection

Make sure your PLC input is of the sinking type for PNP, and update the program to treat a high input as target absent. Allow free space around the head, as it is non-flush, and keep the target size above the sensing face.

Installation

Mount with the stainless nuts supplied, set the gap within the safe sensing range and test both states of the output, free and covered, before releasing the machine.

Maintenance

Clean regularly and inspect the plug and seals. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

As a final check, compare your old sensor’s nameplate with the code IMF18-12NPONC0S. The family has several look-alike types with different polarity, logic, range and installation type, and a wrong guess costs more than a short email. Send the part number 1076667 or a photograph of the old label with your RFQ and mention the quantity and delivery location in Oman or the GCC.

The documentation values worth copying into your asset system are the mean time to dangerous failure of 1,971 years, the mission time of 20 years, the diagnostic coverage of 0 percent, the shock figures of 100 g for 2 ms and 150 g for 1 million cycles and the typical tightening torque of 90 Nm. They show that the sensor is made for demanding duty, while remaining a standard detector without safety certification, and they help the maintenance planner to set realistic inspection intervals.

Where a plant already uses the NPN version, do not mix the two on the same input card without checking each channel, because a PNP and an NPN sensor on one common wiring bus can look identical until the first start.

During commissioning, test both end states with the machine stopped: with a metal target in front of the face the output of the IMF18-12NPONC0S should be off, and with the face clear it should be on. If your PLC shows the opposite, check whether an NO and NC sensor have been swapped, a common mix-up in spare parts stores. Also confirm the visual adjustment indicator behaves as expected, then run the machine slowly for several cycles and watch for flicker, which would indicate a gap that is too close to the limit of the safe sensing range. Finally, label the cable at both ends with the type code so future technicians can tell the normally-closed unit from its normally-open sibling at a glance, even when the sensor body is wet or dirty.

Questions buyers ask about IMF18-12NPONC0S

What logic does SICK IMF18-12NPONC0S use? PNP with normally-closed function: the output is on while the face is free and switches off when a metal target comes within 12 mm.

What range does IMF18-12NPONC0S have? Sn is 12 mm and Sa 9.72 mm, non-flush, in an M18 x 1 body 65 mm long with 39 mm of thread.

Which environments is IMF18-12NPONC0S for? Hygienic and washdown zones and difficult application conditions, with IP68, IP69K and resistance to cleaning agents.

What mounting hardware comes with IMF18-12NPONC0S? Two V4A stainless steel nuts; connection is a 4-pin M12 male connector and the sensing face is LCP plastic.

How is IMF18-12NPONC0S different from IMF18-12NNSNC0S? Only in the output stage and logic: PNP normally closed here, NPN normally open on the other code; range, housing and ratings are identical.

Documents and quotation

The manufacturer datasheet for IMF18-12NPONC0S comes with this listing. Send an RFQ with the part number IMF18-12NPONC0S, quantity and delivery location in Oman or the GCC for availability and lead time.

Datasheets & Documents
  • PDF Datasheet SICK IMF18-12NPONC0S IP69K Inductive Sensor, 12 mm, PNP NC Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.

SICK company profile

Founded 1946, Munich, Germany, by Erwin Sick (1909–1988)
Headquarters Waldkirch, Baden-Württemberg, Germany (since 1956)
Ownership Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996
Size More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023)
First breakthrough Accident-prevention light curtain for presses, shown in Hanover in 1952
International growth First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide
Product families Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring

Milestones

  • 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
  • 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
  • 1956: The company moves to Waldkirch with 25 employees.
  • 1972 and 1976: Subsidiaries are founded in France and the United States.
  • 1996: SICK becomes an Aktiengesellschaft.
  • Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.

Choosing a SICK sensor

For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.

Where SICK products are used

In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.

SICK products we list

Family Examples
Photoelectric sensors WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link
Proximity, cylinder and ultrasonic sensors IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork
Machine safety nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD
Encoders and motor feedback DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50
Distance sensors and code readers DT50, DL50, DT35, Lector632

Ordering SICK products: what we need

Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.

Frequently requested SICK models: SICK RT-P3231 ZoneControl Background Suppression Sensor.

Facts checked against SICK's published company history and annual figures, October 2026.

FAQ

Questions about the SICK IMF18-12NPONC0S IP69K Inductive Sensor, 12 mm,

Answers from our engineering team on installation, compatibility and integration.

01What logic does SICK IMF18-12NPONC0S use?
PNP with normally-closed function: the output is on while the face is free and switches off when a metal target comes within 12 mm.
02What range does IMF18-12NPONC0S have?
Sn is 12 mm and Sa 9.72 mm, non-flush, in an M18 x 1 body 65 mm long with 39 mm of thread.
03Which environments is IMF18-12NPONC0S for?
Hygienic and washdown zones and difficult application conditions, with IP68, IP69K and resistance to cleaning agents.
04What mounting hardware comes with IMF18-12NPONC0S?
Two V4A stainless steel nuts; connection is a 4-pin M12 male connector and the sensing face is LCP plastic.
05How is IMF18-12NPONC0S different from IMF18-12NNSNC0S?
Only in the output stage and logic: PNP normally closed here, NPN normally open on the other code; range, housing and ratings are identical.