Keyence EV-118M Inductive Proximity Sensor M18, Shielded
Description
EV-118M: what this EV series sensor is and how its code reads
EV-118M is a Keyence EV series product, listed by the maker as: Main Unit, Shielded Type, M18. The EV series is a family of self-contained inductive proximity sensors in threaded metal housings, available shielded and unshielded in M8 to M30 sizes. The amplifier is inside the housing, so the sensor connects straight to a PLC input. Seven Star LLC supplies EV-118M in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
EV is the series, 118 means M18 thread, and M denotes shielded. The unshielded sibling is EV-118U.
EV-118M offers a 5 mm distance with a 350 Hz response frequency and nickel-plated brass housing. Being shielded, it can be flush-mounted in metal brackets, which is useful on machine frames and valve brackets.
EV-118M technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Keyence / EV-118M |
| Product description | Main Unit, Shielded Type, M18 |
| Type | Shielded |
| Shape | M18 |
| Detecting distance | 5 mm ±10% |
| Detectable object | Ferrous metals (see Characteristics for nonferrous metals) |
| Standard target (iron, t=1 mm 0.04″ ) | 18 x 18 mm |
| Hysteresis | 10% max. of detecting distance |
| Response frequency | 350 Hz |
| Operation mode | N.O. |
| Temperature characteristics | ±10% max. of detecting distance at 23°C , within -25 to +70°C |
| Control output (switching capacity) | 5 to 200 mA |
| Protection circuit | Reversed polarity, short-circuit, surge voltage |
| Cable length | 2 m |
| Rating | Power voltage: 12 to 24 VDC, Ripple (P-P) 20 % or less |
| Current consumption (leakage current) | Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m cable) |
| Residual voltage | Residual voltage: 3.6 V max. (with 2-m cable) |
| Environmental resistance | Enclosure rating: IP67 |
| Ambient temperature | -25 to +80 °C (No freezing) |
| Relative humidity | 35 to 95 % RH (No condensation) |
| Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm , 2 hours in each of the X, Y, and Z directions |
| Shock resistance | 1,000 m/s² , 3 times in each of the X, Y, and Z directions |
| Case material | Nickel-plated brass |
| Weight | Approx. 150 g |
Values in the table are taken from the maker’s model page for EV-118M. Treat them as nominal and confirm the exact conditions in the instruction manual before final design.
How the sensing principle behind EV-118M works
An inductive proximity sensor generates a high-frequency magnetic field at its face. When a metal object approaches, eddy currents damp the oscillation, and the electronics switch the output once the amplitude falls below a threshold. Because nothing touches the target, the sensor has no moving parts to wear.
Shielded types concentrate the field at the face so they can be flush-mounted in metal, while unshielded types project a wider field and reach farther. The detecting distance in the table assumes the standard target stated for that model, and non-ferrous metals are detected at a reduced distance.
Where EV-118M fits: related EV series parts
EV sensors replace limit switches on valve positions, door latches, cylinder ends and guard checks. Two-wire and three-wire versions exist, so confirm wiring and the PLC input type.
The EV series range includes the following part numbers, which are listed for cross-reference: EV-108M, EV-112M, EV-118M, EV-130M, EV-108U, EV-112U, EV-118U, EV-130U, EV-12M, EV-18M and EV-30M. Whether a particular combination is compatible should be confirmed from the maker’s documents. Closely related models from the same family that you may also want to compare include EV-130U, EV-108U.
Selecting EV-118M: ordering checklist
- Thread size (M8, M12, M18, M30) and shielded or unshielded.
- Detecting distance versus the real gap, with margin for target material.
- Output type, polarity and operating mode (N.O.).
- Cable length or connector.
- Temperature range and enclosure rating.
- Tightening torque and mounting nuts.
For EV-118M specifically, confirm the output type, the connection style and the rated distance shown in the table above against the real installation drawing before placing an order.
Installing and maintaining EV-118M
Tighten the lock nuts evenly, keep unshielded types clear of surrounding metal by the distance stated in the manual, and set the working gap to roughly half the rated distance for stable operation. Protect cables from mechanical damage.
Because there is no calibration, maintenance is limited to inspecting the face and cable, confirming the indicator lamp responds, and checking that mounting has not loosened from vibration.
Typical applications of EV-118M in Oman and the GCC
Inductive sensors are used throughout Oman and GCC oil and gas, power and water facilities for valve-position feedback, machine tool end stops, conveyor counting and rotating-speed detection. The metal housing tolerates dust, heat and vibration on pumps, skids and compressor packages.
Flush-mounted M18 sensors are common on valve brackets and machine frames. Extra heat, dust and humidity are normal in the region, so check the ambient temperature and enclosure rows in the table against the real mounting location, including direct sunlight on outdoor skids.
EV series models compared with EV-118M
The table lists the EV series models in our current range with the maker’s own description, to help you see how EV-118M differs from its neighbours.
| Model | Maker description |
|---|---|
| EV-118M | Main Unit, Shielded Type, M18 |
| EV-130U | Main Unit, Unshielded Type, M30 |
| EV-108U | Main Unit, Unshielded Type, M8 |
Information to send with your EV-118M RFQ
- Exact part number: EV-118M (and quantity, including any matching transmitter, receiver, reflector or head).
- Output polarity required by your PLC input card (NPN or PNP).
- Cable length or connector type and the mounting method.
- Ambient conditions: temperature, washdown, dust and direct sunlight.
- Project reference, delivery location in Oman or the GCC and required lead time.
- Any related items needed, such as brackets, cables, reflectors or a mating amplifier.
Documents and quotation
Send us the part number EV-118M and we will confirm available documents, including the maker’s datasheet and instruction manual where we can provide them. Prices are quoted per request and are not shown on this page.
Seven Star LLC is an independent supplier in Muscat serving Oman and the GCC. We are not affiliated with the manufacturer, and we quote against your RFQ with delivery and lead time confirmed in the quotation.
Other Models in the Keyence Ev Range
Seven Star LLC supplies models from the Keyence Ev range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Keyence EV-130U Inductive Proximity Sensor M30, Unshielded | Inductive Proximity Sensors | View details |
| Keyence EV-118M Inductive Proximity Sensor M18, Shielded | Inductive Proximity Sensors | You are viewing this model |
Reviews (0)
How would you rate this product? Cancel reply
About brand
Keyence is a Japanese maker of sensors, measuring instruments and machine vision, founded in 1974 by Takemitsu Takizaki and headquartered in Osaka. It sells directly to factories and makes photoelectric and laser sensors, code readers, vision systems, measurement systems and microscopes.
Seven Star LLC sources and supplies Keyence sensors and code readers for machine builders and maintenance teams in Oman and the GCC.
Keyence company profile
| Founded | 1974, Japan |
|---|---|
| Founder | Takemitsu Takizaki |
| Headquarters | Osaka, Japan |
| Sales model | Direct sales |
| Product families | LR-Z and LR-W laser and photoelectric sensors, SR-X code readers, IV and CV-X vision systems, LJ-X laser profilers |
Keyence series listed
Three series appear on this page. The LR-Z is a self-contained CMOS laser sensor. Keyence describes it as detecting by distance and by received light, with one-button teaching, a stainless steel body rated IP68/69K and a range of up to 500 mm depending on the model; the LR-ZB250CP is the listed type. The LR-W500C is a full-spectrum reflective photoelectric sensor from the LR-W series. The SR-X100 is an autofocus 2D code reader.
Keyence products we list
Ordering Keyence sensors: what we need
Keyence type codes are short but exact. Send the complete model, such as LR-ZB250CP, because the letters at the end decide the output type and the connection. Remember that many Keyence sensors need a separately ordered cable or connector, and code readers need a cable, a power supply and often a mounting bracket. List those items, the cable length, and the communication interface your PLC uses.
Facts checked against Keyence's published company profile, October 2026.
FAQ
Questions about the Keyence EV-118M Inductive Proximity Sensor M18,
Answers from our engineering team on installation, compatibility and integration.
01What is Keyence EV-118M?
EV-118M is a Keyence EV series product described by the maker as: Main Unit, Shielded Type, M18. Seven Star LLC supplies it in Oman and the GCC as an independent supplier.
02Can EV-118M be mounted flush in metal?
Yes, it is a shielded type, so it can be flush mounted; follow the clearance in the manual.
03What is the response frequency of EV-118M?
The datasheet lists 350 Hz with an N.O. operation mode.
04Does Seven Star LLC supply EV-118M in Oman?
Yes, we quote EV-118M on request for Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer. Send the part number and quantity with your RFQ and we confirm availability and lead time.
05What should I check before ordering EV-118M?
Check output polarity, connection style, the rated distance or range in the specification table, the ambient temperature at the installation point and any matching accessories. Send the part number and we will confirm available documents.