SICK IME30-15BNSZC0K M30 Flush Inductive Sensor, 15 mm

Description

SICK IME30-15BNSZC0K for flush installations

Many machine bases are simple drilled blocks, and a sensor that must stand proud of the surface is inconvenient. The SICK IME30-15BNSZC0K (part number 1041037) is a flush-mountable M30 x 1.5 inductive sensor with 15 mm nominal range, a short 52 mm brass body and an NPN normally-open output through a 4-pin M12 plug. The letter B in the code stands for flush, which is how it differs from the long-range N-types.

Sensing data

The nominal range of 15 mm has a safe sensing range of 12.15 mm. Hysteresis is 3 to 15 percent, reproducibility is up to 2 percent, and temperature drift is plus or minus 10 percent. The switching frequency of 500 Hz and a start-up delay of up to 125 ms make it suited for moderate-speed detection such as cams and gears. Because flush types have shielded coils, nearby metal does not disturb the field the way it does with non-flush types.

  • Reduction factors: stainless about 0.8, aluminium about 0.45, copper and brass about 0.4
  • Short-circuit and power-up pulse protection
  • Housing brass nickel-plated, sensing face PA 66
  • Tightening torque up to 100 Nm

IME30-15BNSZC0K data table

Parameter Value
Part number 1041037
Thread / design M30 x 1.5, short body
Installation Flush
Sn / Sa 15 mm / 12.15 mm
Supply 10 V DC to 30 V DC
Output NPN, normally open, DC 3-wire
Switching frequency 500 Hz
Time delay before availability Up to 125 ms
Connection Male connector M12, 4-pin
Housing length / thread length 52 mm / 35 mm
Tightening torque Up to 100 Nm
Enclosure rating IP67
Operating temperature Minus 25 to plus 75 C
MTTFD 1,735 years

How IME30-15BNSZC0K differs from other IME30 variants

Against the IME30-38NNSZC0S, this sensor gives less range, 15 mm instead of 38 mm, but five times the speed, 500 Hz against 100 Hz, and it can be embedded in metal. It is also 19 mm shorter. Its housing torque rating of 100 Nm is higher than the 70 Nm of the long-range type, which makes it more tolerant of heavy-handed tightening on rough sites.

Typical applications

Press and stamping tools, gear and sprocket pulse detection, clamp position on fixtures and end-of-stroke detection on large cylinders are the typical uses. In heavy workshops in Oman, the flush body is protected from collisions with moving loads because it stays within the bracket.

Selection

Verify the polarity: NPN needs a sourcing input. Choose flush types where the sensor must not protrude, and keep the target at no more than about two thirds of the safe sensing range for margin. Check that the M30 thread and 35 mm thread length fit your hole.

Installation

Use the brass nuts supplied, observe the torque limit and align the target to pass the sensing face centrally. Test over the full temperature range of the machine if possible.

Maintenance

Check for mechanical damage and metal swarf. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Additional planning facts: the datasheet quotes MTTFD of 1,735 years, DCavg of 0 percent, EMC compliance to EN 60947-5-2, an ambient range of minus 25 to plus 75 degrees Celsius and shock resistance of 30 g for 11 ms. The sensing face is PA 66 plastic, so avoid contact with aggressive solvents. Because the sensor is a plain three-wire DC device without IO-Link, it has no parameters to configure, which keeps spare handling simple: any identical type code can be fitted and will behave in the same way. State the code IME30-15BNSZC0K and part number 1041037 in your RFQ, plus the quantity and delivery location, and our team will respond with stock and lead time.

When choosing between flush and non-flush M30 sensors, remember that a flush design has a shielded coil and a shorter range, while a non-flush design sees further but needs free space. The IME30-15BNSZC0K belongs to the first group, so it can be dropped into a block of steel and still reach 15 mm in front of its face, with a guaranteed switching distance of 12.15 mm. Many maintenance teams standardise on flush M30 types for this reason, since a single bore diameter and torque setting then covers all positions on a machine, and spare handling becomes much simpler.

Typical start-up checks for the IME30-15BNSZC0K include verifying the supply voltage at the sensor, not only at the cabinet, because long cable runs can lower the voltage below the 10 V minimum under load. The device drops about 2 V internally at full current, so a controller input that needs a high logic level close to the supply should be checked with the sensor connected. It is also worth confirming that the sensor LED indication and the PLC input agree, which rules out wiring errors such as swapped output and ground conductors on freshly made cables.

Questions buyers ask about IME30-15BNSZC0K

Can SICK IME30-15BNSZC0K be mounted flush? Yes, the installation type is flush, so the sensing face can sit level with surrounding metal while keeping the 15 mm nominal range.

What speed does IME30-15BNSZC0K reach? Switching frequency is 500 Hz with reproducibility up to 2 percent, hysteresis of 3 to 15 percent and availability within 125 ms.

What are the body dimensions of IME30-15BNSZC0K? M30 x 1.5 short body, 52 mm long with a 35 mm thread, brass nickel-plated, up to 100 Nm tightening torque.

What output has IME30-15BNSZC0K? NPN normally open on a DC 3-wire circuit through a 4-pin M12 male connector, with continuous current up to 200 mA.

What is the safe sensing range of IME30-15BNSZC0K? Sa is 12.15 mm for a nominal Sn of 15 mm.

Documents and quotation

The manufacturer datasheet for IME30-15BNSZC0K comes with this page. Send an RFQ with the part number IME30-15BNSZC0K, quantity and your delivery point in Oman or the GCC for availability and lead time.

Other Models in the Sick Ime30 Range

Seven Star LLC supplies models from the Sick Ime30 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
SICK IME30-38NNSZC0S M30 Inductive Sensor, 38 mm Triple RangeInductive Proximity SensorsView details
SICK IME30-15BNSZC0K M30 Flush Inductive Sensor, 15 mmInductive Proximity SensorsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet SICK IME30-15BNSZC0K M30 Flush Inductive Sensor, 15 mm Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.

SICK company profile

Founded 1946, Munich, Germany, by Erwin Sick (1909–1988)
Headquarters Waldkirch, Baden-Württemberg, Germany (since 1956)
Ownership Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996
Size More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023)
First breakthrough Accident-prevention light curtain for presses, shown in Hanover in 1952
International growth First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide
Product families Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring

Milestones

  • 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
  • 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
  • 1956: The company moves to Waldkirch with 25 employees.
  • 1972 and 1976: Subsidiaries are founded in France and the United States.
  • 1996: SICK becomes an Aktiengesellschaft.
  • Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.

Choosing a SICK sensor

For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.

Where SICK products are used

In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.

SICK products we list

Family Examples
Photoelectric sensors WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link
Proximity, cylinder and ultrasonic sensors IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork
Machine safety nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD
Encoders and motor feedback DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50
Distance sensors and code readers DT50, DL50, DT35, Lector632

Ordering SICK products: what we need

Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.

Frequently requested SICK models: SICK RT-P3231 ZoneControl Background Suppression Sensor.

Facts checked against SICK's published company history and annual figures, October 2026.

FAQ

Questions about the SICK IME30-15BNSZC0K M30 Flush Inductive Sensor, 15

Answers from our engineering team on installation, compatibility and integration.

01Can SICK IME30-15BNSZC0K be mounted flush?
Yes, the installation type is flush, so the sensing face can sit level with surrounding metal while keeping the 15 mm nominal range.
02What speed does IME30-15BNSZC0K reach?
Switching frequency is 500 Hz with reproducibility up to 2 percent, hysteresis of 3 to 15 percent and availability within 125 ms.
03What are the body dimensions of IME30-15BNSZC0K?
M30 x 1.5 short body, 52 mm long with a 35 mm thread, brass nickel-plated, up to 100 Nm tightening torque.
04What output has IME30-15BNSZC0K?
NPN normally open on a DC 3-wire circuit through a 4-pin M12 male connector, with continuous current up to 200 mA.
05What is the safe sensing range of IME30-15BNSZC0K?
Sa is 12.15 mm for a nominal Sn of 15 mm.