Brand:

Selectarc Inox 308B E308L-15 Basic Stainless Electrode

Description

Basic-coated 308L electrode for positional stainless work

The Selectarc Inox 308B is a low-carbon austenitic stainless steel electrode with a basic coating, classified AWS A5.4 E308L-15 and ISO 3581-A / EN 1600 E 19 9 L B 4 2. The deposit contains about 8% ferrite. Selectarc highlights a stable arc, good slag removal, regular beads, good behaviour in positional welding and on poorly prepared joints, and strong mechanical properties.

It is intended for 18/8 stainless steels with service temperatures from -196 °C up to +350 °C, with tubes, tanks, heat exchangers and piping systems as the main applications.

Technical specifications

Parameter Specification
Manufacturer / product Selectarc / Inox 308B
Process SMAW (stick, MMA)
AWS classification A5.4 E308L-15
ISO / EN classification 3581-A and EN 1600 E 19 9 L B 4 2
Coating Basic, about 8% ferrite
Typical weld metal, % C under 0.04, Si 0.4, Mn 1.6, Cr 19.0, Ni 9.5, Fe balance
Yield strength Rp0.2 Above 380 MPa
Tensile strength Rm Above 560 MPa
Elongation A5 Above 35%
Impact energy KV Above 90 J at +20 °C; above 30 J at -196 °C
Sizes (diameter × length) and current 2.5 × 300 mm, 70 A; 3.2 × 350 mm, 90 A; 4.0 × 350 mm, 120 A
Current type DC, electrode positive
Redrying 1 h at 250 °C, if necessary
Interpass temperature Below 150 °C
Service temperature -196 °C to +350 °C

Base materials and choosing basic over rutile

Selectarc lists UNS S30400 and S30403 (304 and 304L, 1.4301 and 1.4306), S32100 (321, 1.4541) and S34700 (347, 1.4550). The low carbon content of the deposit limits carbide precipitation, which matters for corrosion resistance of welds in 304L and stabilised grades.

The -15 suffix means a basic coating used on DC only. Compared with rutile 308L types, basic stainless electrodes usually give a convex bead and slightly harder slag, but better out-of-position control and lower sensitivity to porosity, plus better toughness at cryogenic temperatures. The impact value above 30 J at -196 °C on the data sheet supports use on low-temperature equipment in 304L.

Welding notes

Austenitic stainless steels are welded without preheat and with controlled heat input. Keep the interpass temperature below the 150 °C stated by Selectarc, use stringer beads or narrow weaves, and redry electrodes for 1 hour at 250 °C if they have picked up moisture. Clean the joint with stainless-only brushes and tools to avoid iron contamination.

The three diameters cover thin wall tube (2.5 mm at 70 A) through to medium plate (4.0 mm at 120 A). For pickling and passivation after welding, follow your corrosion specification.

For dissimilar joints between stainless and carbon steel, or for buffer layers on clad plate, a higher-alloyed 309L-type electrode is normally specified instead of 308L, because dilution from the carbon steel would otherwise leave too little chromium and nickel in the joint. Inox 308B is the choice for matching 18/8 stainless joints. Where a project requires a ferrite range, measure it on the procedure test piece with a calibrated ferritescope; the typical value from Selectarc is about 8%.

Documents and quotation

The Selectarc Inox 308B data sheet is attached to this page. Browse our Welding Electrodes category for other stainless and alloy electrodes.

For a quotation, send the diameter, quantity and certificate requirement, for example EN 10204 3.1.

How the Inox 308B Electrode Works

Inox 308B is a basic-coated stainless steel electrode depositing a 19-9 type (308) weld metal for austenitic stainless steels. Selectarc notes it performs well on badly prepared joints, which is useful in repair work and site fabrication.

Inox 308B Base Materials

Selectarc lists 304 (1.4301), 304L (1.4306), 321 (1.4541) and 347 (1.4550).

Storage, Handling & Welding Practice

Store electrodes in their original packaging in a dry place, and re-dry electrodes that have absorbed moisture according to the conditions printed on the Selectarc datasheet and packaging. Humidity in coastal areas of Oman and the GCC makes correct storage especially important, because moisture in the coating can cause porosity and, in ferritic steels, increases the risk of hydrogen cracking. Clean the joint of rust, oil, paint and moisture before welding, use the current range given for each diameter, and remove slag fully between passes.

Selection & Ordering Guide

  • Diameter: choose the diameter for plate thickness, position and pass type; smaller diameters for root and positional welding.
  • Base material: confirm the grade against the base materials listed below and on the datasheet.
  • Quantity: order by packet or carton according to your consumption.

Our team can help confirm the correct ordering code and diameter for your job.

Typical Applications in Oman & the GCC

Selectarc lists tubes, tanks, heat exchangers and piping. Across Oman and the GCC, Inox 308B is used in food and beverage plants, water treatment, HVAC and general stainless fabrication.

Why Source from Seven Star LLC

Seven Star LLC supplies Selectarc welding electrodes across Oman and the GCC for fabricators, contractors and maintenance teams. Send us the grade, diameter and quantity to request a quote, and our team can help confirm the correct ordering code.

Tips for Welding Stainless Steel with Coated Electrodes

Keep heat input moderate, use stringer beads or limited weaving, and control interpass temperature to protect corrosion resistance. Use stainless steel brushes and grinding discs reserved for stainless work to avoid iron contamination, and clean or pickle the weld area after welding where the application requires full corrosion performance.

Procedure Qualification and Inspection

For code work, the electrode is normally used within a qualified welding procedure specification, and welders are qualified for the process and position. Check the classification and approvals shown on the Selectarc datasheet against your project specification, keep batch certificates where required, and inspect finished welds visually and by the non-destructive methods your code calls for. Our team can help you obtain the documentation needed for your quality records.

When you request a quote, tell us the base material grade, plate or pipe thickness, welding position and the quantity per diameter. With this information our team can propose the right electrode diameters and packing, and point out where a different grade from the Selectarc range may suit the joint better.

Datasheets & Documents
  • PDF Datasheet Selectarc Inox 308B technical data sheet (EN) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Selectarc is the French maker of welding and brazing filler metals: covered electrodes, TIG rods, MIG and flux-cored wires, submerged arc wires and brazing alloys. Its welding business began in 1952, when Selectarc Industrie started producing covered electrodes, and it is headquartered in Grandvillars in the Territoire de Belfort. Selectarc belongs to Viellard Migeon & Compagnie, a family industrial group whose origins go back to 1796, and since June 2025 the nuclear company Framatome has held a 40% stake.

Seven Star LLC is an independent supplier in Muscat. We list Selectarc electrodes and wires for fabricators and maintenance workshops in Oman and the GCC.

Selectarc company profile

Welding business founded 1952, Grandvillars, France, as Selectarc Industrie, a covered electrode plant
Parent group Viellard Migeon & Compagnie (VMC), a family-controlled industrial group with roots in the Morvillars forges, 1796
Shareholders VMC as majority shareholder; Framatome acquired 40% in June 2025 to secure filler metal supply for nuclear reactor primary circuits
Headquarters Grandvillars, Territoire de Belfort, France
Product families Nickel alloy, stainless, duplex and super duplex, low-alloy and carbon steel electrodes, TIG rods, flux-cored and submerged arc wires, hardfacing electrodes, brazing alloys

Milestones

  • 1796: The Viellard family's metalworking activity starts at Morvillars, the origin of today's VMC group.
  • 1952: Selectarc Industrie begins producing covered welding electrodes in Grandvillars.
  • 2025: Framatome takes a 40% stake in Selectarc on 11 June, alongside majority shareholder VMC.

Selectarc product series

Covered electrodes are the largest group here. Nickel alloy electrodes include Ni625 (ENiCrMo-3), Ni182 (ENiCrFe-3), Ni276 (ENiCrMo-4), Ni59 (ENiCrMo-13) and Ni617 (ENiCrCoMo-1). Stainless and duplex grades include Inox 308B, 316L, 317L, 347, 2209, 2209B and the super duplex Inox 2509MoB. For carbon and low-temperature steels there are the B7018S (E7018-1) and the nickel-alloyed B81, B82 and B84 electrodes, and HB60 is a hardfacing electrode for 55 to 60 HRC.

The range also includes submerged arc wires such as UP 2209 and flux-cored wires, while brazing alloys are made at the former Reboud-Roche foundry.

Where Selectarc filler metals are used

Corrosion-resistant overlays and dissimilar joints in oil and gas and petrochemical plants, duplex and super duplex piping, cryogenic and low-temperature steels, high-temperature alloys and wear-resistant hardfacing. Selectarc names the nuclear, defence and aerospace industries among its key markets.

Selectarc products we list

Family Examples
Welding Electrodes B7018S E7018-1 Basic Low-Hydrogen Electrode, B81 E8018-C3 1% Ni Low-Temperature Electrode, B82 E8018-C1 2.5% Ni Low-Temperature Electrode, B84 E8018-C2 3.5% Ni Cryogenic Steel Electrode, HB60 Hardfacing Electrode 55-60 HRC, Inox 2209 E2209-17 Duplex Stainless Electrode, Inox 2209B E2209-15 Basic Duplex Electrode, Inox 2509MoB E2594-15 Super Duplex Electrode and 12 more
Flux-Cored Welding Wire FCW 2209P E2209T1 All-Position Duplex, FCW 2509MOP E2594T1 Super Duplex Flux-Cored, FCW 309LP E309LT1-1/-4 All-Position, FCW 316LP E316LT1-1/-4 All-Position, FCW NI182 ENiCrFe3T0-4 Nickel Flux-Cored Wire, FCW NI625 ENiCrMo3T0-4 Nickel Flux-Cored Wire
Submerged Arc Welding Wire UP 2209 ER2209 Duplex Submerged Arc Wire, UP 2509 ER2594 Super Duplex Submerged Arc Wire, UP EB3 EB3R 2.25Cr-1Mo Submerged Arc Wire, UP NI625 ERNiCrMo-3 Nickel Submerged Arc Wire, UP P91 EB91 9Cr-1Mo Submerged Arc Wire, UP S2Mo EA2 0.5% Mo Submerged Arc Wire

Ordering Selectarc filler metals: what we need

Give the product name, for example Selectarc Ni625, and the AWS or ISO classification in your welding procedure, the diameter and length, and the quantity. Seven Star LLC checks the grade against the Selectarc technical data sheet and can provide the data sheet and the certificates issued with the order on request.

Facts checked against Framatome's June 2025 announcement and published histories of Viellard Migeon & Cie, October 2026.

FAQ

Questions about the Selectarc Inox 308B E308L-15 Basic Stainless

Answers from our engineering team on installation, compatibility and integration.

01What is the AWS class of Selectarc Inox 308B?
AWS A5.4 E308L-15, a basic-coated low-carbon 308L electrode.
02Which steels does Inox 308B weld?
304, 304L, 321 and 347 austenitic stainless steels.
03What service temperature range is given?
From -196 °C up to +350 °C.
04Can Inox 308B run on AC?
No. The data sheet shows DC with the electrode positive.
05What is the redrying cycle?
1 hour at 250 °C, if necessary.