Hach Ultraturb Seawater sc online turbidity sensor for seawater, brackish water and raw water

The Hach Ultraturb Seawater sc is a flow-through (bypass) online turbidity sensor with an automatically self-cleaning sample chamber, designed for water that contains salt. It measures from 0.0001 to 1,000 FNU (NTU) and tolerates salt concentrations up to 65 g/L, so it can be used on seawater, brackish water and raw water as well as on filtered water, effluent and distribution systems. Seven Star LLC supplies the Ultraturb Seawater sc in Oman and the GCC as an independent supplier in Muscat, and this page explains its measuring principle, ordering variants and installation points for desalination and process water.

Measuring principle: 90 degree scatter with ratio detection

The sensor uses a 90 degree infrared pulse scattered-light technique according to EN ISO 7027-1:2016. In addition to the 90 degree detector, it uses detection at 180 degrees in a ratio method, which minimises reflections in the measuring cell and from the windows. The manufacturer notes that this means fouling of the sample chamber is detected sooner than with a single detector. The sensor meets the ISO 7027 requirements for online process turbidity. The range can be programmed as FNU, NTU, TE/F or EBC and the manufacturer states that 1 FNU is equivalent to 1 NTU.

Technical specifications of the Ultraturb Seawater sc

Parameter Specification
Manufacturer / part number Hach / Ultraturb Seawater sc (LPV415.99.x2002)
Measurement method 90 degree infrared scattered light, EN ISO 7027-1:2016, with ratio detection
Range 0.0001 … 1,000 FNU (NTU)
Accuracy ±0.008 FNU or ±1 % of reading, whichever is greater (0 … 10 FNU)
Repeatability ±0.003 FNU or ±0.5 % of reading, whichever is greater (0 … 2 FNU)
Response time 1 … 60 s, programmable
Verification StablCal
Salt tolerance Salt concentrations up to 65 g/L
Sample flow rate 0.2 … 1 L/min
Sample temperature Maximum 50 °C; operating range 2 … 40 °C
Pressure 6 bar at 20 °C
Inlet and outlet 13 mm ID tubing or fixed connection
Automatic wiper Yes, silicon wiper blades in the sample chamber with magnetic coupling
Materials Housing ASA; window quartz; wiper blade silicon; wiper shaft stainless steel 1.4571; wiper arm titanium alloy
Enclosure rating IP55
Dimensions / weight 270.4 x 277 x 111 mm (H x W x D) / about 1.5 kg
Display Through a Hach sc controller

Ordering variants of the Ultraturb Seawater sc

Order code Cable length Notes
LPV415.99.12002 0.35 m Sensor with auto clean
LPV415.99.82002 1 m Sensor with auto clean
LPV415.99.22002 5 m Sensor with auto clean
LPV415.99.32002 10 m Sensor with auto clean

The data sheet notes that a Hach sc controller is required and must be bought separately. The SC4500 controller accepts up to two sensors and the SC1000 up to eight; several controllers can be networked. Digital extension cables are listed from 0.35 m to 50 m. Spare parts include a set of four wiper blades (LZV275) and a wiper holder (LZV842), and calibration tools include a formazin turbidity standard (4000 NTU, 100 mL) and a calibration and cleaning kit (LZV451).

Why self-cleaning and ratio detection matter in saline water

Turbidity in a bypass sensor is measured in a small chamber, so biofilm, scale or air bubbles on the windows can drift the reading. The wipers clean the chamber automatically, which the manufacturer says gives stable measured values. The ratio detection helps spot chamber fouling early, so cleaning or service can be planned. Because the housing is ASA plastic with a quartz window and a titanium alloy wiper arm, the wetted parts are chosen to cope with the salt content. Entrained air from pressure drops in a sample line can be misread as turbidity, which is why the sample flow rate (0.2 to 1 L/min) and a bubble-free line are important.

Selection and ordering checklist for the Ultraturb Seawater sc

  • Sample salinity: confirm that it does not exceed 65 g/L; for desalination brine check the actual TDS.
  • Turbidity range: the sensor spans 0.0001 to 1,000 FNU, but accuracy figures are stated for 0 to 10 FNU.
  • Cable length between the sensor and the controller, and extension cables if the distance is greater.
  • Controller: SC4500 (two sensors) or SC1000 (up to eight sensors) with the right outputs and communication.
  • Sample line material and fittings, and pressure below 6 bar at the sensor.
  • Verification and calibration standards and spare wiper blades.

Installation and maintenance

Install the sensor on a bypass line with a stable flow in the stated range, use the inlet at the bottom so that air can leave at the outlet, and avoid dead legs. Pressure above 6 bar or a sample hotter than 50 °C is outside the data sheet. After commissioning, verify the sensor with the StablCal-type standard and check the zero with a filtered sample. Replace the wiper blades on a schedule that matches the fouling of the water, and keep the quartz window clean with the calibration and cleaning kit. Record the verification results so that trending of the sensor health is possible.

Typical applications in Oman and the GCC

The Ultraturb Seawater sc suits seawater intake and pretreatment monitoring before reverse osmosis membranes, filter effluent turbidity at desalination and power plant water treatment, brackish groundwater supplies, cooling water make-up and raw water at industrial sites. Turbidity before a membrane stage is an early indicator of filter breakthrough, and online data helps protect the membranes and meets operating limits set by the plant.

Information to send with an RFQ for the Ultraturb Seawater sc

  • Order code or required cable length
  • Sample type, salinity and temperature
  • Controller model and number of sensors
  • Spare wipers, calibration and verification standards
  • Quantity and delivery site

Documents and quotation

The Hach Ultraturb Seawater sc data sheet is attached on this page. It lists the technical data, order codes, spares and calibration tools.

Send the application data and Seven Star LLC will confirm availability and prepare a quotation.

Datasheets & Documents
  • PDF Datasheet Hach Ultraturb Seawater sc Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Hach is the American specialist in water quality analysis: spectrophotometers and reagents, laboratory meters, online analysers for chlorine, turbidity, nutrients and dissolved oxygen, and controllers. Clifford and Kathryn (Kitty) Hach founded the company in 1947 in Ames, Iowa, with USD 15,000 that Clifford had earned from a patent, and their first success was a simplified titration test for water hardness. Hach moved its headquarters to Loveland, Colorado, in 1978, was acquired by Danaher in 1999, and is now part of Veralto.

Seven Star LLC lists Hach online analyzers, controllers, sensors, portable meters and reagents, and sources them for water, wastewater, power and process plants in Oman.

Hach company profile

Founded 1947, Ames, Iowa, USA
Founders Clifford C. Hach (chemist) and Kathryn "Kitty" Hach (sales, marketing and operations)
Headquarters Loveland, Colorado, USA (since 1978); reagent manufacturing remains in Ames
Ownership Public from 1968; Danaher from 1999; part of Veralto (NYSE: VLTO) since the 2023 separation from Danaher
Product families DR series spectrophotometers and test reagents, HQ and sensION meters, SC controllers, online chlorine, turbidity, nutrient, oxygen and TOC analysers, samplers

Milestones

  • 1947: Clifford and Kitty Hach start the company in Ames, Iowa.
  • 1968: Hach becomes a public company.
  • 1978: Headquarters move to Loveland, Colorado.
  • 1999: Danaher acquires Hach.
  • 2004: Hach combines with Dr. Bruno Lange GmbH of Germany.
  • 2023: Hach becomes part of Veralto, separated from Danaher.

Hach analyzers, sensors and reagents listed

The Hach products on this page fall into four main groups, plus a few accessories such as a colorimeter, a reagent dispenser, a power supply and a flow control valve:

  • Online analyzers: CL17sc colorimetric chlorine analyzer, TU5300sc and TU5400sc laser turbidimeters, BioTector B3500ul TOC analyzer, Polymetron 9245 sodium analyzer and Orbisphere 510 dissolved gas analyzer
  • Controllers and digital sensors: SC4500 controller and the LDO 2 luminescent dissolved oxygen sensor
  • Portable and laboratory instruments: 2100Q turbidimeter, HQ4200 multi-parameter meter and IntelliCAL probes such as the LBOD101
  • Reagents: DPD free chlorine powder pillows and DEHA reagents for oxygen scavenger testing

Polymetron and Orbisphere analyzers are aimed at power plant water-steam cycles and similar pure water duties, where sodium, dissolved oxygen and other gases are measured at low levels.

Where Hach instruments are used

Hach instruments appear in drinking water plants, desalination, sewage treatment, cooling and boiler water circuits, and industrial effluent monitoring across the GCC. Operators use the portable meters and reagents for spot checks, and the sc analyzers and probes for continuous signals to the control system.

Hach products we list

Family Examples
Liquid Analytical Systems BioTector B3500ul Online TOC Analyzer, CL17sc Colorimetric Chlorine Analyzer, DR3900 Benchtop VIS Spectrophotometer, DR6000 UV-VIS Spectrophotometer with RFID, Orbisphere 510 Multichannel Gas and Dissolved, Polymetron 9245 Single-Channel Sodium Analyzer, SC4500 Digital/Analog Controller, TU5300sc and TU5400sc Online Laser
Liquid Analytical Accessories 6000 HACH Reagent Dispenser, 21055-69 DPD Free Chlorine Reagent Powder, 21679-69 DEHA Reagent 1 Powder Pillows, 21680-42 DEHA Reagent 2 Solution, Valve for Flow Control
Liquid Analysis Sensors Colorimeter, LBOD101 IntelliCAL Laboratory Luminescent, LXV416.99.20001 LDO2 Dissolved Oxygen Sensor, Power Supply
Portable Test & Measurement 2100Q Portable Turbidimeter (EPA), DR1900 Portable Spectrophotometer, HQ4200 Portable Multi-Parameter Water Quality

Ordering Hach products: what we need

Hach identifies every item by a catalog number, for example LXV416.99.20001 for a sensor or 21055-69 for a reagent pack, and the same reagent may be written with or without the dash. Send that number and the quantity. For analyzers and controllers, add the parameter and range, sample conditions, power supply, outputs and communication option. For sensors, tell us the controller model they will connect to and the cable length. For reagents, name the instrument and method so pack size and range can be confirmed against Hach documentation.

Facts checked against Hach's published company history, October 2026.

FAQ

Questions about the Hach Ultraturb Seawater sc Online Turbidity Sensor

Answers from our engineering team on installation, compatibility and integration.

01What turbidity range does the Ultraturb Seawater sc cover?
It covers 0.0001 to 1,000 FNU (NTU), with accuracy stated as plus or minus 0.008 FNU or 1 percent of reading in the 0 to 10 FNU range.
02Can it be used with seawater?
Yes. The sensor is resistant to salt concentrations up to 65 g/L and is described for seawater, brackish water and raw water.
03How is the sample chamber kept clean?
An automatic wiper with silicon blades and a magnetic coupling cleans the chamber, and ratio detection helps detect fouling early.
04What controllers are compatible?
Hach sc digital controllers: the SC4500 accepts up to two sensors and the SC1000 up to eight. A controller is bought separately.
05What are the flow and pressure limits?
The sample flow rate is 0.2 to 1 L/min and the pressure range is 6 bar at 20 degrees C.