Brand: Yokogawa
Yokogawa SC4A-S-AD-09-002-05-T1/PS/FF Conductivity Sensor
Description
Yokogawa SC4A-S-AD-09-002-05-T1/PS/FF pure-water conductivity sensor overview
The Yokogawa SC4A-S-AD-09-002-05-T1/PS/FF is a compact 2-electrode contacting conductivity sensor built for low-conductivity water. It is a stainless steel 316L version of the SC4A family with adapter mounting, a 9 cm insertion length, a 0.02 per cm nominal cell constant, a 5 metre fixed cable and a Pt1000 temperature element. The /PS option adds a 3/4 inch NPT stainless steel adapter and the /FF option adds a stainless steel flow fitting, so the sensor can be put into a pipe line or a sample line without extra hardware. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Pure and ultrapure water measurements depend on a very small cell constant, a clean wetted surface and reliable temperature compensation. The Yokogawa SC4A-S-AD-09-002-05-T1/PS/FF addresses all three with a polished body, a pre-calibrated cell and a built-in temperature resistor.
SC4A-S-AD-09-002-05-T1/PS/FF model code explained
| Code element | Meaning |
|---|---|
| SC4A | 19 mm conductivity sensor |
| -S | Stainless steel 316L, sterilizable according to the EHEDG test |
| -AD | Fitting type: adapter mounting |
| -09 | Sensor length 9 cm |
| -002 | Cell constant 0.02 per cm |
| -05 | Fixed cable length 5 m |
| -T1 | Pt1000 temperature element |
| /PS | 3/4 inch NPT stainless steel adapter |
| /FF | Stainless steel flow fitting |
According to the specification note, the 9 cm length is not offered with the Variopin connector version. The SC4A-S-AD-09-002-05-T1/PS/FF uses a fixed cable, so the code is valid, and a fixed-cable sensor is also the version covered by the ATEX and IECEx certification.
Key features of the SC4A-S-AD-09-002-05-T1/PS/FF
- Compact style sensor with a built-in Pt1000 temperature resistor and fast temperature response.
- Pre-calibrated cell constant of 0.02 per cm, suited to very low conductivity.
- Wetted materials of 316L stainless steel, PEEK insulation and FDA-grade EPDM O-ring, with a surface roughness of 0.8 micrometre.
- Compatible with the PR10 retractable assembly and a wide range of mountings.
- A 3.1 material certificate is delivered as standard with the metal sensor.
- Plug and cable form a water-tight connection to IP67, and a fixed-cable version is certified for installation in zone 0 when connected to a suitable intrinsically safe circuit.
The polished finish and the sterilization capability make the SC4A-S-AD-09-002-05-T1/PS/FF relevant for pharmaceutical water as well as boiler feedwater and demineralizer monitoring.
SC4A-S-AD-09-002-05-T1/PS/FF technical specifications
| Parameter | Value |
|---|---|
| Measuring system | 2-electrode (4-wire), Pt1000 to IEC 751 |
| Nominal cell constant | 0.02 per cm |
| Operating range | 1 microsiemens x cell constant to 50 millisiemens x cell constant (about 0.02 microsiemens per cm to 1 millisiemens per cm for this cell) |
| Response time, temperature | t90 under 1 minute |
| Body and electrodes | Stainless steel AISI 316L |
| O-ring | EPDM, FDA grade |
| Insulation | PEEK |
| Mounting adapter | PVDF or stainless steel AISI 316L (this code: stainless steel /PS) |
| Process temperature | 0 to 110 C; 135 C for a short period during sterilization |
| Process pressure | 0 to 10 bar (0 to 142 psig) |
| Maximum cable length | 60 m with WU10/WE10 cable |
| Storage temperature | -30 to 50 C |
| Package | 220 x 220 x 90 mm; 0.5 to 1.7 kg depending on sensor and cable |
The temperature element of the SC4A is intended for measurement compensation and indication, and it is not designed for process temperature control.
ATEX and IECEx data for the SC4A-S-AD-09-002-05-T1/PS/FF
For sensors with a fixed cable, such as SC4A-S-AD-09-002-05-T1/PS/FF, the datasheet lists ATEX certificate DEKRA 14ATEX0074 X with marking II 1 G Ex ia IIC T4 to T6 Ga, and IECEx certificate DEK 14.0032X with marking Ex ia IIC T4 to T6 Ga. The sensor input circuit must be connected to a certified intrinsically safe circuit with maximum values of Ui 14.4 V, Ii 116.5 mA and Pi 0.342 W, or to an intrinsically safe Yokogawa contact conductivity transmitter of the FLXA21 or SC202S series. Temperature classes are T6 for ambient -30 to 40 C, T5 for -30 to 95 C and T4 for -30 to 130 C. The special conditions of use ask that impact and electrostatic charging of the enclosure are avoided.
Applications in Oman and GCC facilities
Power plants and desalination units across the Gulf rely on conductivity measurement to protect boilers, turbines and membranes. The SC4A-S-AD-09-002-05-T1/PS/FF fits condensate polishing, demineralized water headers, reverse osmosis permeate and boiler feedwater sampling. In pharmaceutical, food and beverage and semiconductor utilities, sanitary clamp mountings allow use in purified water loops. In oil and gas and petrochemical plants it can monitor steam condensate return for contamination, which is a frequent cause of fouling and corrosion.
Selection and compatibility notes for SC4A-S-AD-09-002-05-T1/PS/FF
The cell constant should match the expected conductivity: the 0.02 per cm version of the SC4A-S-AD-09-002-05-T1/PS/FF is meant for the lowest range, while the 0.10 per cm code serves slightly higher conductivity. Confirm the process temperature and pressure against the 110 C and 10 bar limits, and note that a PVDF fitting reduces the temperature limit to 80 C, which does not apply to this stainless /PS adapter. The sensor is intended for use with Yokogawa analyzers such as the FLXA21 and SC202S, and it uses WU10 or WE10 cable when extended. When the sensor is replaced, enter the cell constant that is printed on the certificate shipped with it.
Installation and commissioning of the SC4A-S-AD-09-002-05-T1/PS/FF
- Fit the 3/4 inch NPT adapter into the pipe tee or the flow fitting with suitable thread sealing, observing the pressure and temperature limits.
- Insert the sensor so that the electrodes sit fully in the flowing sample, avoiding trapped air pockets.
- Route the 5 m cable away from power wiring and connect it to the analyzer with the correct terminal assignment; keep any extension within 60 m.
- Configure the analyzer with a cell constant of 0.02 per cm, select the Pt1000 temperature element and the temperature compensation matching the water chemistry.
- Verify the reading against a reference conductivity meter or a calibration standard after the sensor has equilibrated.
Maintenance of the SC4A sensor
Keep the electrode surface free of films and deposits. Rinse with clean deionized water and use only cleaning agents compatible with 316L stainless steel, PEEK and EPDM. Inspect the O-ring at each removal and replace it if it is hardened or damaged. For regulated pharmaceutical use, record the certificate number and calibration checks in the maintenance log. Because a contaminated cell shows a drift or an unstable reading in pure water, scheduled verification is better than waiting for a fault. The part number to quote for a replacement is SC4A-S-AD-09-002-05-T1/PS/FF.
Documents and quotation
The Yokogawa general specification GS 12D07J04-01E-E for the SC4A family is available on request and on this page. To receive availability and lead time, send an RFQ with part number SC4A-S-AD-09-002-05-T1/PS/FF and the quantity. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Datasheets & Documents
- Datasheet Yokogawa SC4A-S-AD-09-002-05-T1/PS/FF Conductivity Sensor Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa SC4A-S-AD-09-002-05-T1/PS/FF Conductivity
Answers from our engineering team on installation, compatibility and integration.
01What is the Yokogawa SC4A-S-AD-09-002-05-T1/PS/FF?
It is a Yokogawa SC4A 2-electrode conductivity sensor in stainless steel 316L, 9 cm long, with a 0.02 per cm cell constant, 5 m cable, Pt1000, a 3/4 inch NPT adapter and a flow fitting.
02What conductivity range does the SC4A-S-AD-09-002-05-T1/PS/FF cover?
The datasheet gives an operating range from 1 microsiemens times the cell constant to 50 millisiemens times the cell constant, so about 0.02 microsiemens per cm to 1 millisiemens per cm with a 0.02 per cm cell.
03What are the process limits of the SC4A-S-AD-09-002-05-T1/PS/FF?
Stainless steel and titanium versions are rated 0 to 110 C, up to 135 C briefly for sterilization, and 0 to 10 bar. With a PVDF fitting the limit is 0 to 80 C.
04Which analyzers work with the SC4A-S-AD-09-002-05-T1/PS/FF?
The datasheet names the Yokogawa FLXA21 and SC202S analyzers, including the intrinsically safe versions for fixed-cable ATEX and IECEx use.
05How can I order the SC4A-S-AD-09-002-05-T1/PS/FF in Oman?
Send an RFQ with the full part number and quantity. Seven Star LLC is an independent supplier and replies with availability for Oman and the GCC.


















Reviews