Brand:

Rosemount 03300-1655-0001 5300 2-in. SST Centering Disc

Description

Rosemount 03300-1655-0001: 2-in. stainless centering disc for 8 mm rigid probes

Rosemount 03300-1655-0001 is a centering disc kit for the rigid single lead probe of the Rosemount 5300 guided wave radar level transmitter, in the 0.3 in (8 mm) probe diameter family. The item is described in the datasheet as Kit, 2-in. Centering disc, SST, with an outer diameter of 1.8 in (45 mm). In plain words it is a stainless steel disc that clamps on the probe so the lead stays in the middle of a 2-in. pipe or chamber instead of touching the wall.

Why that matters: a guided wave radar sends a microwave pulse down the probe, and a probe touching a metal wall can disturb the reflection and distort the level reading. The disc keeps a fixed air gap along the length of the probe.

Where the kit applies and how it is ordered

The manufacturer explains the ordering logic clearly. If a centering disc is wanted with a flanged probe, it can be selected inside the transmitter model code using options Sx (stainless) or Px (PTFE). If the probe has a threaded connection, or if the disc is needed as a spare, it is ordered with the item number printed in the accessories table. That is the situation in which this part number is requested: a spare for a threaded 8 mm rigid probe, a replacement for a lost disc, or an addition when an installation is moved to a narrower pipe.

The transmitter these discs serve is a two-model family. The 5301 measures liquid level, or interface where the probe is fully submerged, and the 5302 measures level and interface in the same instrument. Both use Direct Switch Technology and Probe End Projection to cope with low-reflective media and long ranges, offer HART 4-20 mA, FOUNDATION Fieldbus or Modbus outputs, and can be safety certified to IEC 61508 with option QT. A disc is thus a small mechanical part that supports a sophisticated measurement; a loose disc rattles in the pipe and is easier to spot during a shutdown walk-round than to diagnose from the echo curve.

Data table for 03300-1655-0001

Parameter Value
Part number 03300-1655-0001
Description Kit, 2-in. Centering disc, SST
Outer diameter 1.8 in (45 mm)
Probe it fits Rigid single lead, 0.3 in (8 mm) diameter
Pipe or chamber size 2-in.
Disc material Stainless steel (SST)
Availability marking Starred, i.e. most common, fastest delivery
Matching probe type 4A Rigid Single Lead (8 mm)
4A probe length min 1 ft 4 in (0.4 m), max 9 ft 10 in (3 m)
Reference accuracy of the 5300 0.12 in (3 mm) or 0.03 percent of distance, whichever is greater
Repeatability 0.04 in (1 mm)
Update rate minimum 1 update per second

The datasheet also reminds users that for probes with spacers, accuracy may deviate close to the spacers, so mount the disc away from the measuring zone of interest whenever the tank design permits.

How 03300-1655-0001 differs from other 5300 centering discs

The same accessory table lists many disc kits that look almost alike. The first digit group separates the probe type: 03300-1655-0001 to 0010 are for rigid 8 mm probes, 03300-1655-0301 to 0310 are for rigid 13 mm probes, and 03300-1655-1001 to 1010 are for flexible single lead probes. Within each group, the last digits give pipe size and material, SST or PTFE, for 2, 3, 4, 6 and 8-in. pipes. So 03300-1655-0001 is the smallest stainless size of the 8 mm family; its PTFE sibling is 03300-1655-0006, and the 3-in. stainless one is 03300-1655-0002. Fitting a 13 mm disc to an 8 mm probe, or the reverse, will not work.

Application notes for Gulf level measurement

  • Narrow still pipes and bypass chambers on separators and knock-out drums, where the lead must stay centred.
  • Condensate and condensed steam vessels with small 2-in. standpipes.
  • Chemical day tanks where a rigid lead hangs inside a small stilling pipe.
  • Retrofits into old chamber connections where the original float cage has been replaced by a radar probe.
  • Level in narrow tanks where the product has a dielectric constant low enough that the minimum of 1.4 (1.25 in a metallic bypass or stilling well) for rigid probes must be respected.

For each of these uses the datasheet specifies that a verification reflector (options HL1, HL2, HL3) can be added to check the device online, and HL1 is meant for 3- to 6-in. pipes or chambers; in a 2-in. pipe the reflector options are therefore not applicable and the disc is the only mechanical accessory fitted to the lead. Process engineers should confirm that the 2-in. pipe size is clear of weld spatter and deposits, since any ridge inside the pipe can wedge the disc and bend the rod during insertion.

Installation and checkout

Measure the pipe inner diameter, confirm the 2-in. class, and check the probe is the rigid 8 mm type. Slide 03300-1655-0001 onto the lead at the position determined from the vessel drawing and fix it as directed in the kit instruction. Trim the probe to length only if the manufacturer procedure allows it; the datasheet says probes can be cut to exact length in the field, and maximum allowable length is determined by process conditions. Re-run the transmitter threshold and Trim Near Zone routines afterwards, then compare the reading against a manual dip at two levels.

Maintenance and inspection

The 5300 itself is a multivariable device with HART, FOUNDATION Fieldbus or Modbus output, and its echo curve is available in AMS Device Configurator, DD and DTM tools, so any change in the disc echo can be seen from the control room. Disc kits are passive and need only visual checks: inspect for product build-up on the rim, for corrosion at the clamp, and for the disc slipping down the lead after vibration. A stainless disc is the appropriate choice where the probe is stainless steel; for different probe alloys the datasheet says to consult the factory for other materials. Keep a spare disc in the tool store of the instrument workshop.

Documents and quotation

The 5300 datasheet listing 03300-1655-0001 in its accessories table is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Please send an RFQ with part number 03300-1655-0001, the quantity and the probe type and length of your 5300 to confirm fit, with the delivery location in Oman or the GCC.

Other Models in the Rosemount 5300 Probe Spares Range

Seven Star LLC supplies models from the Rosemount 5300 Probe Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Rosemount 03300-1655-0001 5300 2-in. SST Centering DiscRadar & Guided Wave Radar LevelYou are viewing this model
Rosemount 03300-1658-0001 5300 Snap-On PEEK DiscRadar & Guided Wave Radar LevelView details
Rosemount 03300-1655-0307 5300 3-in. PTFE Centering DiscRadar & Guided Wave Radar LevelView details
Datasheets & Documents
  • PDF Datasheet Rosemount 03300-1655-0001 5300 2-in. SST Centering Disc Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 03300-1655-0001 5300 2-in. SST Centering

Answers from our engineering team on installation, compatibility and integration.

01What is Rosemount 03300-1655-0001?
It is a 2-in. stainless steel centering disc kit, 1.8 in (45 mm) outer diameter, for the 8 mm rigid single lead probe of the Rosemount 5300.
02When should I order the item number instead of a model code option?
The datasheet says to use the item number when the disc is for a threaded connection or needed as a spare; flanged probes can take option S2 in the model code.
03Does 03300-1655-0001 fit 13 mm probes?
No. Discs for the 13 mm rigid probe start at 03300-1655-0301; the 0001 series is for the 0.3 in (8 mm) rigid probe.
04What is the PTFE equivalent?
The 2-in. PTFE disc for the same 8 mm rigid probe is listed as 03300-1655-0006.
05What accuracy does the 5300 give?
The datasheet states reference accuracy of 0.12 in (3 mm) or 0.03 percent of measured distance, whichever is greater, with 0.04 in (1 mm) repeatability.