Brand:

Rosemount 03300-1655-0307 5300 3-in. PTFE Centering Disc

Description

Quick facts: 03300-1655-0307 PTFE centering disc, 3-in., 13 mm rigid probe

  • Rosemount 03300-1655-0307 is listed as Kit, 3-in. Centering disc, PTFE, outer diameter 2.7 in (68 mm).
  • It belongs to the table for rigid single lead probes of 0.5 in (13 mm) diameter on the Rosemount 5300 level transmitter.
  • It carries the star mark in the datasheet, meaning it is among the most common options with shorter delivery.
  • Intended for threaded probes or as a spare; flanged probes may take option P3 in the model code instead.
  • Not available with high temperature and high pressure probe codes: PTFE discs exclude Operating Temperature and Pressure code H and probe material codes 7 and 8.

These bullets answer the usual first question about 03300-1655-0307; the sections below add the engineering context.

What a PTFE disc offers

A polytetrafluoroethylene disc is chemically inert and electrically insulating. In guided wave radar the disc is a material change along the probe, so its dielectric behaviour matters to the echo curve; the manufacturer lists PTFE and stainless as the two disc materials for rigid probes and says to consult the factory for other materials. A PTFE disc is the usual choice for aggressive products such as acids and for probes that are PTFE covered, while a stainless disc is preferred when heat is a concern.

Specification summary

Parameter Value
Part number 03300-1655-0307
Description Kit, 3-in. Centering disc, PTFE
Outer diameter 2.7 in (68 mm)
Probe diameter 0.5 in (13 mm) rigid single lead
Matching probe type 4B Rigid Single Lead (13 mm)
4B probe length min 1 ft 4 in (0.4 m), max 19 ft 8 in (6 m)
Minimum dielectric constant, rigid probes 1.4 standard, 1.25 in a metallic bypass or stilling well
Verification reflector for 3- to 6-in. pipe option HL1
Disc option code in model P3
Same-size stainless version 03300-1655-0302
Same-diameter 8 mm probe version 03300-1655-0007

Reading 03300-1655-0307 against its neighbours

The family is a grid. Rows are pipe sizes of 2, 3, 4, 6 and 8 inches; columns are probe diameter and disc material. 03300-1655-0307 sits at 3-in., 13 mm, PTFE. Moving one place to the left in material gives 03300-1655-0302 (stainless). Moving to the 8 mm probe gives 03300-1655-0007 (3-in. PTFE). Moving to the flexible probe group gives 03300-1655-1007. The diameter of the disc is the same across probe types for a given pipe size, 2.7 in (68 mm) for 3-in. pipes, but the hole that grips the lead differs, so the part numbers cannot be swapped.

Another practical consideration is the minimum gap between disc and wall. A 3-in. pipe class has an inner diameter near 3 in., and the 2.7 in (68 mm) disc leaves a small clearance so that the assembly slides in without jamming yet cannot swing. If the pipe has an unusual inner diameter, for instance a thick-walled schedule 160 pipe, check the bore before ordering, and mention it in the RFQ so the correct disc class can be confirmed from the datasheet table.

Typical installation sites

Gas-liquid separators with 3-in. stilling wells, sample pots, condensate pots and bypass chambers on boilers are the usual homes. Along the Gulf coast, where fuel and water-treatment chemicals are stored in similar pipe-fed chambers, the PTFE version handles corrosive duties better than uncoated steel. The datasheet’s verification reflector (HL1) is specified for 3- to 6-in. pipes or chambers, so the same size class often includes a reflector too.

Pressure and temperature class of the whole probe assembly is chosen on the transmitter model code, with options for standard, medium temperature and medium pressure, high pressure, high temperature and high pressure, and cryogenic builds. The disc kit does not change those ratings, but its material must suit the same process; PTFE discs are not offered with the high temperature and high pressure code H, which keeps the PTFE material away from the harshest thermal duty. Review the application sheet before purchase.

Fitting procedure

Measure the inside of the pipe or chamber and decide the position of the disc along the lead; the datasheet says discs can be ordered for pipe installations to keep the probe centred. Place 03300-1655-0307 over the lead end, move it to position, and secure it as instructed. Keep the disc clear of the reflector and of probe weights. After refitting the transmitter, observe the echo curve with the AMS or DTM tools to see that the disc produces only a small, stable echo that the software can ignore.

Where the transmitter is delivered as a complete assembly with Rosemount chambers, the centering discs are normally fitted in the factory using option P3. A replacement made years later, however, comes from the accessories table, and the item number of the kit is the only reliable way to identify it. Photograph the old disc before removal and record the position along the lead, measured from the flange face, in the plant maintenance system.

Care and spares planning

PTFE can cold flow under a clamp load, so recheck the grip after the first thermal cycles. Replace any disc that is cracked, chemically attacked or loose. For plants with several vessels, stock a few of each size and material so a replacement takes minutes.

Record the inner bore, the lead diameter and the disc material on the asset card of the transmitter so that the next maintenance team can reorder the correct kit without opening the vessel.

Documents and quotation

The datasheet listing 03300-1655-0307 is attached. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. To obtain a quotation, send an RFQ stating 03300-1655-0307, the quantity, and the probe type and diameter of the 5300 you are maintaining, with the delivery address in Oman or the GCC.

Other Models in the Rosemount 5300 Probe Spares Range

Seven Star LLC supplies models from the Rosemount 5300 Probe Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Rosemount 03300-1655-0001 5300 2-in. SST Centering DiscRadar & Guided Wave Radar LevelView details
Rosemount 03300-1658-0001 5300 Snap-On PEEK DiscRadar & Guided Wave Radar LevelView details
Rosemount 03300-1655-0307 5300 3-in. PTFE Centering DiscRadar & Guided Wave Radar LevelYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Rosemount 03300-1655-0307 5300 3-in. PTFE Centering Disc Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 03300-1655-0307 5300 3-in. PTFE Centering

Answers from our engineering team on installation, compatibility and integration.

01What size is Rosemount 03300-1655-0307?
It is a 3-in. pipe size PTFE centering disc with an outer diameter of 2.7 in (68 mm) for the 13 mm rigid single lead probe.
02Can the PTFE disc be used on every 5300 probe?
No. The datasheet says PTFE discs are available for probe types 4A, 4B, 4S and 5A, but not with operating temperature and pressure code H or material codes 7 and 8.
03What is the stainless equivalent?
The 3-in. stainless disc for the same 13 mm rigid probe is 03300-1655-0302.
04Which option code would replace this item in a model string?
For a flanged probe, option P3 specifies a 3-in. PTFE centering disc in the transmitter model code.
05What is the minimum dielectric constant for a rigid probe?
Table 3 gives 1.4 for standard rigid single lead probes, or 1.25 when installed in a metallic bypass or stilling well.