- Automation & ControlView all 2,895 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Magnetrol
Magnetrol Z30-9165-001 HART Wiring Board for Eclipse 706 and Pulsar
Description
Magnetrol Z30-9165-001 overview: wiring board for the Eclipse Model 706
The Magnetrol Z30-9165-001 is the replacement HART wiring PC board for the Eclipse 706 and the Pulsar R96. The Eclipse 706 manual lists it for HART units (5th digit 1, 6th digit 2) and the Pulsar R96 manual lists it for HART units (5th digit 1, 6th digit 1). Maintenance planners search for this exact number because the Eclipse Model 706 is built in many variants, and a board or module for the wrong variant can leave a level or flow loop out of service during a shutdown window.
The picture on this page is the manufacturer product image for the Eclipse Model 706 guided wave radar level transmitter, which is the family that uses the Z30-9165-001. It is not a close-up of the wiring board itself. Every value below comes from the manufacturer manual 57-606 and catalog pages for that family, and where a value is not published for this specific part we have left it out instead of guessing.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Z30-9165-001 so that buyers can quote the number exactly as printed in the manual, and we confirm availability against your quotation request.
Key features of Z30-9165-001
- Exact manufacturer part number Z30-9165-001, shown in the replacement parts section of manual 57-606.
- Function: wiring PC board for the Eclipse Model 706, selected by the model number digits printed on the transmitter nameplate.
- Fits the Eclipse Model 706 guided wave radar level transmitter, which the manufacturer describes as follows: The Eclipse 706 is a guided wave radar transmitter based on time domain reflectometry. A pulse travels down a probe, reflects at the liquid surface and returns, and the electronics convert the transit time to level.
- Replacing a plug-in or board-level part can restore a loop without replacing the whole instrument, which keeps process piping, flanges and the probe or antenna untouched.
- The manual advises that the nameplate model and serial number should always be quoted when spare parts are ordered.
Z30-9165-001 technical specifications
| Parameter | Value |
|---|---|
| Manufacturer | Magnetrol (AMETEK) |
| Part number | Z30-9165-001 |
| Part type | Wiring PC board |
| Used in | Eclipse Model 706 guided wave radar level transmitter |
| Measurement principle | Guided wave radar, time domain reflectometry (TDR) |
| Output options | 4 to 20 mA with HART, FOUNDATION fieldbus, PROFIBUS PA, Modbus |
| Loop resistance, HART | 591 ohms at 24 VDC and 22 mA |
| Accuracy, coaxial, caged and single rod probes | 0.1 percent of probe length or 0.1 in (2.5 mm), whichever is greater |
| Fieldbus supply | 9 to 17.5 VDC |
| Safety option | SIL 2/3 certified, HART only |
| Replacement O-ring | 012-2201-237 |
| Manual | 57-606 |
The family values in the table describe the instrument that the Z30-9165-001 belongs to and are quoted from manual 57-606. The Z30-9165-001 itself is a replacement part and carries the model-code rules summarized in the selection section below.
Typical applications for the Eclipse Model 706 and Z30-9165-001 in Oman and the GCC
Instruments of this family are used in external cages and bridles on separators and drums, boiler feedwater and condensate vessels, interface measurement in oil and water, and chemical and utility tanks. In Oman and across the GCC these duties appear in oil and gas production and processing, petrochemical and fertilizer plants, power and desalination stations, municipal water and wastewater works, and general manufacturing.
Typical reasons to buy a spare such as the Z30-9165-001 are a failed board after a lightning surge or moisture ingress, a unit that has reached the end of service life, or a plant that wants a spare on the shelf for critical tags instead of waiting for a long lead time during an outage.
Selection and compatibility notes for Z30-9165-001
The Eclipse 706 manual lists it for HART units (5th digit 1, 6th digit 2) and the Pulsar R96 manual lists it for HART units (5th digit 1, 6th digit 1). Always compare the full model number on the nameplate with the manual before ordering, because boards for different outputs, approvals and housings are not interchangeable.
- Read the 5th and 6th digits of the model number first. They set the output and safety option and decide which electronics are fitted.
- Read the classification digit next. Explosion-proof, flameproof, intrinsically safe and non-sparking versions can use different boards.
- Confirm the display and housing digits if the part is a display, cover or housing-related item.
- Send the serial number with the RFQ so the part can be checked against the configuration of the instrument.
If you are unsure whether Z30-9165-001 is right for your tag, send us the nameplate photo and we will compare it with the parts list before quoting. The manual also names related spares for this family, including Z31-2849-001, Z31-2849-002 and Z31-2858-001 electronic modules, Z30-9165-001, Z30-9166-002 and Z31-2859-001 wiring boards, display module 089-9136-001, adapter 032-6923-001, and cable weight assemblies 089-9120-001 and 004-8778-001.
Installation and commissioning with Z30-9165-001
Shut down the loop, remove power and open the correct compartment. Replace only with the part number that matches the transmitter model digits shown on the nameplate, then re-check probe length and level offsets because the probe itself is not changed by this part.
Follow the safety instructions of the manufacturer manual 57-606 for the hazardous area classification of the installation. In classified areas do not open housings while the circuit is live unless the area is known to be non-hazardous, and re-fit all covers and O-rings fully before power is restored. After fitting the Z30-9165-001, record the date, the tag and the part number in the maintenance log.
Maintenance and spare strategy
Inspect the O-ring (012-2201-237) whenever the cover is opened, verify the probe is free of buildup, and keep configuration records for each tag.
For critical level and flow measurements many plants keep one wiring board such as the Z30-9165-001 per instrument family on site. This shortens repair time because the technician only has to swap the part and reload the configuration instead of waiting for a complete replacement transmitter.
Related products and ordering notes for Z30-9165-001
Other spares in the same family that buyers often request together with Z30-9165-001 include Z31-2849-001, Z31-2849-002 and Z31-2858-001 electronic modules, Z30-9165-001, Z30-9166-002 and Z31-2859-001 wiring boards, display module 089-9136-001, adapter 032-6923-001, and cable weight assemblies 089-9120-001 and 004-8778-001. These are listed in the manufacturer manual under replacement parts, and we can quote them in the same RFQ.
For each line please state the part number, the quantity, the tag number and the delivery location in Oman or the GCC. We will confirm availability and lead time and return a written quotation.
FAQ summary
- What is the Magnetrol Z30-9165-001? The Z30-9165-001 is the replacement HART wiring PC board for the Eclipse 706 and the Pulsar R96. It is listed in the replacement parts section of the manufacturer manual 57-606.
- Which instrument uses the Z30-9165-001? It is listed for the Eclipse Model 706 guided wave radar level transmitter. The Eclipse 706 manual lists it for HART units (5th digit 1, 6th digit 2) and the Pulsar R96 manual lists it for HART units (5th digit 1, 6th digit 1).
- How do I confirm that Z30-9165-001 matches my instrument? Compare the model number digits on the nameplate with the parts list in manual 57-606 and send us the model and serial number with your RFQ so we can confirm the part number before quoting.
- Can Seven Star LLC supply Z30-9165-001 in Oman? Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with Z30-9165-001, the quantity and the delivery location and we will confirm availability.
- Is documentation available for Z30-9165-001? Yes. The manufacturer manual 57-606 with the replacement parts list is available from this page as a datasheet download, and the nameplate data of your unit should always be checked against it.
Documents and quotation
The manufacturer manual 57-606 for the Eclipse Model 706 is attached to this page as the datasheet for Z30-9165-001. It contains the replacement parts list, model number tables, wiring diagrams and specifications referred to above. To request a quotation, send the RFQ with the part number Z30-9165-001, the quantity, the instrument tag and the nameplate model and serial number. Seven Star LLC will reply with availability and lead time for Oman and the GCC.
Other Models in the Magnetrol E706 Range
Seven Star LLC supplies models from the Magnetrol E706 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Magnetrol Z31-2849-002 Fieldbus Electronic Module for Eclipse 706 GWR | Radar & Guided Wave Radar Level | View details |
| Magnetrol Z31-2858-001 PROFIBUS PA Electronic Module for Eclipse 706 | Radar & Guided Wave Radar Level | View details |
| Magnetrol Z30-9165-001 HART Wiring Board for Eclipse 706 and Pulsar | Radar & Guided Wave Radar Level | You are viewing this model |
| Magnetrol Z30-9166-002 Fieldbus Wiring Board for Eclipse 706 GWR | Radar & Guided Wave Radar Level | View details |
| Magnetrol Z31-2859-001 Modbus Wiring Board for Eclipse 706 GWR | Radar & Guided Wave Radar Level | View details |
Datasheets & Documents
- Manual Magnetrol Z30-9165-001 HART Wiring Board for Eclipse 706 and Pulsar Manual with Parts List Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Magnetrol is the American level and flow measurement specialist known for the Eclipse guided wave radar, Pulsar radar transmitters and the float and displacer switches that guard boilers and vessels. It was founded in 1932, is based in Aurora, Illinois, and has been part of AMETEK since 2021.
Seven Star LLC is an independent supplier in Muscat. We list Magnetrol level transmitters and level and flow switches, and supply them to refineries, gas plants and utilities in Oman and the GCC by complete model number.
Magnetrol company profile
| Established | 1932, USA; headquarters in Aurora, Illinois |
|---|---|
| Ownership | Acquired by AMETEK in March 2021 and now part of its Electronic Instruments Group |
| Product families | Guided wave radar, non-contact radar, displacer and buoyancy transmitters, ultrasonic and thermal dispersion switches, float switches and magnetic level indicators (through its Orion Instruments brand) |
| Applications | Separators, storage tanks, boilers and feedwater heaters, interface measurement, pump protection and flow detection |
Milestones
- 1932: The first mechanical buoyancy level switch; the company grows into Magnetrol, based in Aurora, Illinois.
- 1998: Eclipse Model 705, a loop-powered guided wave radar transmitter for industrial liquid level, according to Magnetrol.
- 2021: AMETEK acquires Magnetrol on 29 March.
Magnetrol products we list
| Model | Principle | Typical use |
|---|---|---|
| Eclipse 706 | Guided wave radar | Level and interface in separators, chambers and boiler drums, unaffected by changing density |
| Pulsar R80 | 80 GHz FMCW radar | Narrow-beam non-contact level in tanks with internals and in solids |
| Pulsar R86 | 26 GHz radar | Non-contact level in process and storage vessels |
| Pulsar R96 | 6 GHz radar | Non-contact level where vapour, foam or condensation are present |
| E4 Modulevel | Displacer | Level and interface in high-pressure, high-temperature vessels, often replacing older torque tube units |
| Echotel 961/962 | Ultrasonic gap switch | High and low level alarms and pump protection |
| Thermatel TD1/TD2 | Thermal dispersion switch | Flow and no-flow detection and level switching for liquids and gases |
Guided wave radar sends pulses down a probe and times the reflection from the surface, so dust, vapour and changes in density don't affect the reading. That is why it often replaces displacers on separators and chambers. Non-contact radar suits tanks where nothing should touch the product, and a higher frequency gives a narrower beam that avoids tank internals.
Where Magnetrol instruments are used
In Oman and the GCC, Magnetrol transmitters and switches measure level in production separators, slug catchers, storage tanks, boiler drums and feedwater heaters, and protect pumps in oil and gas, refining, petrochemical, power and water plants.
Ordering Magnetrol instruments: what we need
Send the complete model number from the nameplate. On Magnetrol instruments every digit sets the electronics, the probe or antenna, the process connection and the approvals. For a new application, send the medium, the dielectric constant if known, the measuring range, the pressure and temperature, the process connection and the hazardous area classification.
Facts checked against Magnetrol and AMETEK company information, October 2026.
Browse Magnetrol products by category: Level Transmitter.
FAQ
Questions about the Magnetrol Z30-9165-001 HART Wiring Board for
Answers from our engineering team on installation, compatibility and integration.
01What is the Magnetrol Z30-9165-001?
The Z30-9165-001 is the replacement HART wiring PC board for the Eclipse 706 and the Pulsar R96. It is listed in the replacement parts section of the manufacturer manual 57-606.
02Which instrument uses the Z30-9165-001?
It is listed for the Eclipse Model 706 guided wave radar level transmitter. The Eclipse 706 manual lists it for HART units (5th digit 1, 6th digit 2) and the Pulsar R96 manual lists it for HART units (5th digit 1, 6th digit 1).
03How do I confirm that Z30-9165-001 matches my instrument?
Compare the model number digits on the nameplate with the parts list in manual 57-606 and send us the model and serial number with your RFQ so we can confirm the part number before quoting.
04Can Seven Star LLC supply Z30-9165-001 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with Z30-9165-001, the quantity and the delivery location and we will confirm availability.
05Is documentation available for Z30-9165-001?
Yes. The manufacturer manual 57-606 with the replacement parts list is available from this page as a datasheet download, and the nameplate data of your unit should always be checked against it.


















Reviews
There are no reviews yet.