Brand:

Danfoss 060-114466 KP 36 Pressure Switch Gold Contact

Description

060-114466 overview: Danfoss KP 36 with gold contacts and a fine differential

Where the silver twin of this switch drives contactors, Danfoss 060-114466 is the variant for delicate circuits. It keeps the 4.0 to 12.0 bar setting range and the 0.5 to 1.6 bar differential of the KP 36 narrow-band version, but swaps the contact surfaces for gold-plated silver. The result is a pressure switch that can feed a controller input or a safety relay that sources only a few milliamps.

It is housed in the same IP30 body as other KP and KPI switches, and the product page lists a net weight of 0.3 kg and the application as air compressors. Pressure enters through a G 1/4 A connector.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Gold contact data you should know

Gold plating is thin. The datasheet therefore gives two ratings: a low-level rating for the period when the plating is intact, and a heavier rating that applies once the gold has burned away. The product page quotes 1 to 30 mA at 5 to 30 V for the gold surface. The load that remains after the gold has gone is AC-1 10 A at 440 V, AC-3 6 A at 440 V, AC-15 4 A at 440 V and DC-13 12 W at 220 V.

The practical lesson is to decide once: either keep the circuit at logic level for the whole life of the switch, or choose the silver version. Switching a heavy load only occasionally spoils the benefit of gold.

Datasheet values for 060-114466

Parameter Value
Code number 060-114466
Type KP 36
Range 4.0 to 12.0 bar
Differential 0.5 to 1.6 bar
Operating pressure 17 bar
Test pressure 22 bar
Connection G 1/4 A
Contact SPDT, gold-plated silver
Gold low-level rating 1 to 30 mA, 5 to 30 V
Reset Automatic
Enclosure IP30
Ambient temperature -40 to 65 C
Medium Gas, -40 to 100 C
Weight 0.3 kg net
Terminal capacity 0.75 to 2.5 mm2 solid
EAN 5702423148721

Typical uses of 060-114466 around the Gulf

Electronic control is spreading to older compressor houses and package units in the region. A KP switch with gold contacts lets a technician add a pressure interlock to a PLC without worrying that a dry contact with 24 V and a few milliamps will go intermittent after months in a dusty, humid cabinet.

Examples are the pressure-permissive input of a burner management skid, the air-supply-failure alarm in a plant-air header, or the discharge-pressure trip of a small refrigeration-like pneumatic circuit. Dust and humidity at coastal sites make clean gold surfaces valuable.

How 060-114466 differs from other KP 36 and KPI models

Parameter Value
060-122166 same 4 to 12 bar KP 36, silver contacts for loads up to 16 A
060-114466 same range and differential, gold contacts for 1 to 30 mA
060-113766 KP 36 gold with wider 2 to 14 bar range and 0.7 to 4.0 bar differential
060-118966 KPI 36 for liquids, 4 to 12 bar, differential 0.5 to 1.6 bar, 18 bar limit

So 060-114466 is not simply ‘another KP 36’. It is the combination of low-level contacts and a fine differential that is unique within the list above.

Selection checklist for 060-114466

  • Fluid must be gas; use a KPI model for liquids.
  • Switching current must stay at logic level for gold to retain its benefit.
  • System pressure must remain under 17 bar.
  • Required cut-in must be at least 4 bar; below that choose the 2 to 14 bar KP 36.
  • Open IP30 housing means it belongs in a panel or enclosure.

Wiring and commissioning of 060-114466

Use a 6 to 14 mm cable through the rubber gland. Terminals take 0.75 to 2.5 mm2 solid or stranded wire, or 0.5 to 1.5 mm2 flexible wire with ferrules. Terminal 1 is common; 1-4 closes on rising pressure and 1-2 opens, as in the contact table of the datasheet. Protect the circuit with a fuse not above 16 A, as given in the electrical properties.

Set the range scale to the desired cut-out, adjust the DIFF scale to obtain the restart point, and check with a calibrated gauge.

Care and inspection

Inspect the contact action with the manual trip lever when commissioning and after any long shutdown. If you see unstable readings on the PLC input, check that no inductive load is being switched by the gold contact, and check for condensation inside the housing.

Ordering note

060-114466 is one of two KP 36 codes with 4 to 12 bar range; the other has silver contacts. State the code in full when sending an RFQ so the right contact material is quoted.

Thermal and mechanical limits of 060-114466

Ambient temperature may range from -40 to 65 C, and the housing tolerates 80 C for up to two hours, for example during a brief shutdown in a hot Gulf enclosure. Media temperature is limited to -40 to 100 C. The bellows is phosphor bronze or stainless steel according to the datasheet, and the pressure connector is nickel-plated free-cutting steel or stainless steel.

Dimensionally the product is compact; it is 0.3 kg net, and its shape allows several units to be racked side by side in a panel because the electrical entry is on the front. The datasheet stresses this as a way to save space when mounting on racks.

Typical life depends on the switched load. At logic level the contacts have no appreciable wear, and the main ageing mechanism is mechanical fatigue of the bellows under pressure cycling, so pulsation should be damped for the 060-114466 with a small restrictor if the compressor pulsates strongly.

Documents and quotation

A copy of the industrial KP and KPI datasheet is attached. Send an RFQ with the part number and quantity to receive availability.

What to Include in Your Danfoss 060-114466 Enquiry

An accurate quotation for the Danfoss 060-114466 depends on a few details. Please share the complete part number, any suffix codes for options or approvals, the operating conditions at the installation point, and whether certificates of conformity or test reports must ship with the goods. It also helps to know whether the unit is for planned maintenance, a shutdown or an urgent breakdown, because that decides how it is sourced and shipped. With this information our team can check compatibility with your existing pressure switches and reply with availability and a realistic delivery estimate.

Other Models in the Kp Industrial Range

Seven Star LLC supplies models from the Kp Industrial range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Danfoss 060-122166 KP 36 Pressure Switch 4-12 barPressure SwitchesView details
Danfoss 060-450166 KP 36 Stainless Pressure Switch IP55Pressure SwitchesView details
Danfoss 060-114466 KP 36 Pressure Switch Gold ContactPressure SwitchesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Danfoss 060-114466 KP 36 Pressure Switch Gold Contact Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12, Danfoss VLT AutomationDrive FC 302 Variable Frequency Drive, Danfoss MBS 3000 General Purpose Pressure Transmitter, Danfoss EVR 25 Servo-Operated Solenoid Valve, Danfoss ICV Pilot-Operated Industrial Refrigeration Valve.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss 060-114466 KP 36 Pressure Switch Gold

Answers from our engineering team on installation, compatibility and integration.

01What does the gold contact on 060-114466 do?
It allows reliable switching of very small currents, 1 to 30 mA at 5 to 30 V on the product page, which suits PLC and relay inputs.
02What range and differential does 060-114466 offer?
A setting range of 4.0 to 12.0 bar with a differential adjustable from 0.5 to 1.6 bar.
03What happens when the gold on 060-114466 wears away?
The contacts revert to a rating of AC-1 10 A, AC-3 6 A, AC-15 4 A at 440 V and DC-13 12 W at 220 V.
04How does 060-114466 differ from the silver 060-122166?
The pressure data are the same, but 060-122166 has silver contacts for loads up to 16 A, whereas this code uses gold for low-level signals.
05Which medium is 060-114466 designed for?
Gaseous media, with an operating pressure up to 17 bar and a media temperature from -40 to 100 C.