Brand:

Danfoss 060-508166 KPI 38 Pressure Switch 8-28 bar

Description

Danfoss 060-508166: KPI 38 high-pressure switch for steam, air, gas and liquids

Danfoss 060-508166 is the KPI 38, the top of the KPI single-switch ladder. Where KPI 35 and KPI 36 stop at 18 bar, this device has a setting range of 8.0 to 28.0 bar, a differential adjustable from 1.8 to 6.0 bar, and permissible operating and test pressures of 30 bar. It is the only KPI in the datasheet whose fluid list includes steam together with air, gaseous media and liquids.

The bellows is stainless steel and the connector is nickel-plated free-cutting steel, in contrast to the bronze and brass of the smaller KPI types. The G 1/4 A connector, the IP30 housing and the silver SPDT contacts are common to the rest of the series. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Why the numbers on the KPI 38 are different

A 1.8 bar minimum differential looks coarse next to the 0.4 bar of the KPI 35, but at pressures of 20 bar and above it is a sensible figure: a narrower differential would cause rapid cycling because small pressure ripples would be enough to reverse the contact. The upper limit of 6.0 bar lets a system run with a wide band when a large accumulator is present.

With a 30 bar rating the switch is a candidate for hydraulic accumulator charging checks, boiler feed pumps, high-pressure compressed air at 25 bar, and other duties where an electronic transmitter would be an over-specification.

Technical data of 060-508166

Parameter Value
Code number 060-508166
Type KPI 38
Setting range 8.0 to 28.0 bar
Differential 1.8 to 6.0 bar
Operating pressure 30 bar
Test pressure 30 bar
Connection G 1/4 A
Bellows Stainless steel
Connector Nickel-plated free-cutting steel
Fluids Steam, air, gases, liquids
Contacts SPDT silver, AC-1 16 A 400 V, AC-3 16 A 400 V, AC-15 10 A 400 V, DC-13 12 W 220 V
Product page contact rating AC-15 4 A 440 V, AC-1 10 A 440 V, AC-3 6 A 440 V
Enclosure IP30
Ambient -40 to 65 C
Media temperature -40 to 100 C (datasheet table)
Net weight 0.32 kg
EAN 5702423147335

Applications for 060-508166 in the region

Industrial compressed-air receivers in Duqm and Sohar, small steam lines at food plants, hydraulic power units and washdown pumps at pressures above 12 bar are the places where a KPI 36 would run out of range. The stainless bellows make this a better fit than bronze where condensate or mildly corrosive liquids are present.

Because the housing is open IP30, panel mounting or a separate IP55 enclosure is expected.

How 060-508166 differs from other KPI variants

Parameter Value
060-121766 KPI 35, -0.2 to 8.0 bar, 18 bar limit
060-118966 KPI 36, 4.0 to 12.0 bar, 18 bar limit
060-508166 KPI 38, 8.0 to 28.0 bar, 30 bar limit, stainless bellows, silver contacts
060-541866 KPI 38, same 8.0 to 28.0 bar range and 30 bar limit, listed on a second line of the ordering table; check its variant on the Danfoss page before ordering

Compared with the lower KPI codes, the KPI 38 changes the pressure window, the bellows material and the differential range at the same time.

Selection, installation and setting of 060-508166

Confirm that the maximum pressure plus surge stays below 30 bar. For steam service, use a siphon loop (pigtail) so that live steam does not reach the bellows directly; the media limit of 100 C must be respected at the switch itself. Fit the unit on a flat surface, orient the connector downward, and use a 6 to 14 mm cable.

To set an air compressor to stop at 25 bar and restart at 20 bar, put the range scale at 25 and the DIFF scale at 5. Verify with a calibrated gauge before releasing the plant.

Maintenance

Keep the impulse line clear of scale and oil. Operate the manual trip, check settings once a year, and replace the device if the scale no longer matches a gauge. Never exceed the 30 bar test pressure when pressure-testing the system with the switch connected.

Electrical notes

The insulation rating is 400 V, pollution degree 3, impulse 4 kV, and a 16 A fuse protects the circuit. Terminals take 0.75 to 2.5 mm2 solid wire. The vibration rating on back plate and wall bracket is 0 to 1000 Hz at 4 g.

Ordering

Order 060-508166 by full code and quantity. Similar codes exist for other enclosures.

Extra detail on the stainless KPI 38 design

The datasheet groups the KPI 38 in a column with the boiler-version KP 34 to KP 37 switches, and for all of them the bellows is stainless steel and the connector is free-cutting steel with nickel plating. That is why this column is the only one with steam in its list of fluids. The stainless bellows tolerate thermal cycling better, which is a distinct reason to choose it for a steam or hot-water duty rather than a bronze unit.

It should still be treated as a switch, not a safety limiter with a certified function: where a regulation demands a boiler limiter, the certified KP boiler versions of the family exist for that, and the final approval always depends on the system designer and local authorities.

Using 060-508166 as a pressure limiter or alarm

Because the contact is single-pole double-throw, terminals 1 and 4 can switch an alarm lamp when pressure is above the setpoint while terminals 1 and 2 hold a running circuit. At a hydraulic power unit, for example, the contactor can be wired through 1-2 so that the pump stops at the cut-out, and the lamp through 1-4. The setting spindle moves the whole range, and the differential spindle shifts only the restart point.

Use a calibrated gauge for all final settings, because the scale is only an indication.

Documents and quotation

The KP and KPI datasheet is attached. Send an RFQ with the part number and quantity.

Documentation and Compliance

Industrial buyers often need more than the hardware. When you order the Danfoss 060-508166, tell us which documents your project or quality team requires, such as certificates of origin, conformity declarations, calibration or test records, or hazardous-area certificates where the variant carries them. Mentioning these at the enquiry stage avoids delays at customs and at goods receipt on site. For tenders and project packages, we can also align the quotation with your line-item format so that Danfoss pressure switches items can be checked against the bill of materials quickly.

Datasheets & Documents
  • PDF Datasheet Danfoss 060-508166 KPI 38 Pressure Switch 8-28 bar Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.

Danfoss company profile

Founded 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966)
First product Thermostatic expansion valve for refrigeration
Headquarters Nordborg, Denmark
Ownership Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family
Size About 42,000 employees (2023)
Business segments Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics)
Brands in the group VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls

Milestones

  • 1932–1933: First expansion valve; the company is founded in Nordborg.
  • 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
  • 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
  • 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
  • 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
  • 2021: Acquisition of Eaton's hydraulics business.

Choosing Danfoss products

For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.

Where Danfoss products are used

In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.

Danfoss products we list

Family Examples
Variable speed drives and soft starters VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter
Solenoid valves and coils EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil
Pressure switches and thermostats KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101
Pressure transmitters MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2
HVAC and refrigeration valves AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element

Ordering Danfoss products: what we need

Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.

Frequently requested Danfoss models: Danfoss 132B0101 VLT Control Panel LCP 12.

Facts checked against Danfoss's company history pages and published company data, October 2026.

FAQ

Questions about the Danfoss 060-508166 KPI 38 Pressure Switch 8-28 bar

Answers from our engineering team on installation, compatibility and integration.

01What is the pressure range of Danfoss 060-508166?
The KPI 38 setting range is 8.0 to 28.0 bar with an adjustable differential of 1.8 to 6.0 bar.
02What is the pressure limit of 060-508166?
Permissible operating pressure and maximum test pressure are 30 bar.
03Which fluids can 060-508166 handle?
The datasheet lists steam, air, gaseous media and liquids for the KPI 38 column, with a stainless steel bellows.
04What connection does 060-508166 have?
A G 1/4 A pressure connector in nickel-plated free-cutting steel.
05Why choose 060-508166 instead of a KPI 36?
The KPI 36 stops at 12 bar range and 18 bar limit, whereas this model reaches 28 bar range and 30 bar limit.