Hydac EDS 44F9-6000-1P-DS-000 High-Pressure Ex d Switch 6000 psi
Description
At the top of the 44F9 family sits EDS 44F9-6000-1P-DS-000: a flameproof, programmable pressure switch for 0 to 6000 psi with one PNP output. Its overload rating of 11600 psi and its burst rating of 29000 psi make it suitable for circuits where pressure intensifiers, test rigs or wellhead hydraulics can spike far above the working level. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Where EDS 44F9-6000-1P-DS-000 sits in the range
Six thousand psi is about 414 bar, a pressure at which a mechanical switch would need a heavy piston design. The electronic cell in EDS 44F9-6000-1P-DS-000 is only 0.661 lb in weight yet is tested to nearly five times the range before burst. The switch-point grid at this level is 10 psi, so a set point of 4500 psi can be placed exactly without a gauge reference.
Because the span is large, the quality of the pressure source matters. A 1 percent error equals 60 psi at full scale, so for a test that must be held within a narrow band, compare the switch with a calibrated reference first. The 10 psi grid is fine enough for set points such as 4200 or 5150 psi. Remember too that the temperature coefficient of 0.02 percent per degC typical adds only about 1.2 psi per degree at this range, so it is small next to the basic accuracy.
Key properties
- Range 6000 psi, overload 11600 psi, burst 29000 psi.
- Single PNP output, up to 1.2 A, with N/O or N/C choice.
- Set points in 10 psi steps using the HPG 3000 programming unit.
- Welded cell without internal seals; FKM O-ring seal.
- IP 69K sealed gauge construction.
- Conduit entry 1/2-14 NPT with flying leads.
Technical data of EDS 44F9-6000-1P-DS-000
| Parameter | Value |
|---|---|
| Model code | EDS 44F9-6000-1P-DS-000 |
| Material number (catalog) | 922628 |
| Setting range | 0 to 6000 psi |
| Overload pressure | 11600 psi |
| Burst pressure | 29000 psi |
| Cell type | Sealed gauge (S) |
| Process connection | 1/4-18 NPT, female |
| Tightening torque | 40 N·m (30 lb-ft) |
| Switching outputs | 1 PNP, programmable |
| Output load | max. 1.2 A |
| Switch-point increment | 10 psi |
| Switch point / hysteresis window | 5 to 100 percent / 1 to 96 percent of range |
| Switching delay | 8 to 2000 ms via HPG 3000 programming unit |
| Response time | 8 ms |
| Accuracy | 1 percent FS maximum (0.5 percent typical) |
| Repeatability | 0.1 percent FS maximum |
| Supply voltage | 12 to 30 V DC, ripple 5 percent or less |
| Current consumption | 25 mA plus switching current, 1.225 A total maximum |
| Electrical connection | 1/2-14 NPT conduit, flying leads |
| Core assignment | red +UB, white switch output 1, black 0 V, green SDA (programming), brown not used |
| Switching cycles | more than 100 million |
| Compensated temperature | T5 / T130: -13 to 176 degF; T6 / T110: -13 to 140 degF |
| Storage temperature | -40 to 212 degF |
| Protection | IP 69K (sealed gauge) |
| Vibration | 20 g, 10 to 500 Hz |
| Weight | 0.661 lb (about 300 g) |
| Approvals | ATEX KEMA 10ATEX100 X; CSA MC 224264; IECEx KEM 10.0053X |
Applications
Typical sites are subsea control hydraulic test panels on shore bases, pressure testing skids that handle flammable fluids, mining roof-support hydraulics and high-pressure washdown lines in refineries. In every case EDS 44F9-6000-1P-DS-000 acts as the trip contact that tells a controller that the test pressure has been reached or lost.
How EDS 44F9-6000-1P-DS-000 differs from EDS 44F9-3000-1P-DS-000
The range doubles from 3000 to 6000 psi, the overload from 7250 to 11600 psi and the burst from 14500 to 29000 psi. The increment changes from 5 to 10 psi. Both have the same 1.2 A output, the same cable colours and the same 40 N·m torque. Neither provides a second output; for that you must look at the EDS 4479 type.
Choosing it correctly
If the system works below 3000 psi in normal conditions, the lower-range variant gives finer set-point resolution. Select EDS 44F9-6000-1P-DS-000 only when normal operation lies above about 2000 psi. Confirm that pipe threads rated for 6000 psi are used on the female NPT port side.
Installation
Fit the male stub with a suitable high-pressure sealant and torque to 40 N·m. Hold the hex with a spanner while tightening, never the housing. Connect cores and set the point through the HPG 3000, then pressurise slowly and verify the switching direction.
Maintenance
Cycle count above 100 million switchings makes wear-out unlikely. Where shock loads occur, review the damping of the line, because very fast spikes can exceed even the 11600 psi overload reserve of EDS 44F9-6000-1P-DS-000.
Wiring remains simple: red to the positive rail, black to the negative rail, white to the load input and green to the programming unit only during setup. The brown core stays unused on this one-output model and must be insulated. Always specify the programming unit separately, because it is not included with the switch and the instrument cannot be adjusted without it. Order it together with the switch if the site has no unit on its tool list already.
Ordering Checklist for the Hydac EDS 44F9-6000-1P-DS-000
Before you ask for a quotation for the Hydac EDS 44F9-6000-1P-DS-000, check the full order code on the nameplate of the unit you are replacing, the supply voltage, and the process or signal ranges your system expects. If this is an upgrade rather than a like-for-like swap, tell us the existing make and model so that mounting, wiring and connection details can be checked against the pressure switches already installed. For multi-unit orders, list the quantity per site and the delivery location in Oman or the wider GCC, so packing, paperwork and lead time can be confirmed in a single quotation.
Frequently asked questions about EDS 44F9-6000-1P-DS-000
What overload does EDS 44F9-6000-1P-DS-000 withstand? 11600 psi, with a burst pressure of 29000 psi according to the catalog record.
What is the switch-point increment? 10 psi at the 6000 psi range.
Which approvals are shown? ATEX KEMA 10ATEX100 X, CSA MC 224264 and IECEx KEM 10.0053X.
Is the cell sealed or vented? Sealed gauge, which the S in DS indicates; vented cells stop at 300 psi.
What should I give for an RFQ? The part number EDS 44F9-6000-1P-DS-000, quantity and destination.
Documents and quotation
The datasheet of EDS 44F9-6000-1P-DS-000 is attached to the listing. For availability and lead time, submit an RFQ with EDS 44F9-6000-1P-DS-000, the quantity and the delivery location.
Other Models in the EDS 4400 ExD Range
Seven Star LLC supplies models from the EDS 4400 ExD range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Hydac EDS 4479-3000-2P-DS-000 Two-Output Flameproof Pressure Switch | Pressure Switches | View details |
| Hydac EDS 44F9-6000-1P-DS-000 High-Pressure Ex d Switch 6000 psi | Pressure Switches | You are viewing this model |
| Hydac EDS 44F9-3000-1P-DS-000 Programmable Ex d Pressure Switch | Pressure Switches | View details |
Datasheets & Documents
- Datasheet Hydac EDS 44F9-6000-1P-DS-000 High-Pressure Ex d Switch 6000 psi Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.
Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.
HYDAC at a glance
| Established | 1963, Sulzbach, Saarland, Germany |
|---|---|
| Name | From "hydraulic accumulator", the first product line |
| Ownership | Family-owned; around 50 international subsidiaries |
| Product families | Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring |
HYDAC products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure filters | DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND | Protect servo and proportional valves downstream of the pump |
| Low-pressure, return and suction filters | LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX | Return line, lube oil, turbine oil and suction filtration |
| Breathers and indicators | BF, ELF, BDE dryer, VD clogging indicator | Keep dust and moisture out of the tank and show when an element needs changing |
| Accumulators | SB330 bladder accumulator | Energy storage, pulsation damping and emergency actuation |
| Pressure transmitters | HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP | Pressure measurement in hydraulic and process systems |
| Pressure, temperature and level switches | EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 | Local display plus switching outputs for alarms and interlocks |
Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.
Where HYDAC products are used
In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.
Ordering HYDAC products: what we need
Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.
Facts checked against HYDAC company information, October 2026.
Browse Hydac products by category: Filter Housings, Pressure Instrumentation, Temperature Instrumentation, Filtration Systems, Hydraulic Valves & Components.
FAQ
Questions about the Hydac EDS 44F9-6000-1P-DS-000 High-Pressure Ex d
Answers from our engineering team on installation, compatibility and integration.
01What overload does EDS 44F9-6000-1P-DS-000 withstand?
11600 psi, with a burst pressure of 29000 psi according to the catalog record.
02What is the switch-point increment?
The switch-point increment is 10 psi at the 6000 psi range, per the catalog record.
03Which approvals are shown?
ATEX KEMA 10ATEX100 X, CSA MC 224264 and IECEx KEM 10.0053X.
04Is the cell sealed or vented?
Sealed gauge, which the S in DS indicates; vented cells stop at 300 psi.
05What should I give for an RFQ?
The part number EDS 44F9-6000-1P-DS-000, quantity and destination.


















Reviews
There are no reviews yet.