SICK IMF18-12NNSNC0S IP69K Inductive Sensor, 12 mm, NPN NO
Description
SICK IMF18-12NNSNC0S overview
Where a washdown inductive sensor needs more reach and is installed with free space around the head, the SICK IMF18-12NNSNC0S (part number 1076668) is the logical IMF18 type. It senses at a nominal 12 mm with a non-flush head, switches an NPN normally-open output, and shares the rugged IP68/IP69K housing of the IMF line with an LCP sensing face and stainless V4A mounting nuts.
What the IMF construction gives you
The special features recorded in the datasheet are resistance to cleaning agents, a visual adjustment indicator and temperature resistance, and the special applications are hygienic and washdown zones and difficult application conditions. The sensor tolerates minus 40 to plus 100 degrees Celsius and mechanical shocks of 100 g for 2 ms in 500 cycles or 150 g for 1 million cycles. A vibration sweep from 55 to 500 Hz at 60 g is also listed, which is far beyond the specification of conventional brass sensors.
- Hysteresis 3 to 20 percent, reproducibility up to 2 percent
- Switching frequency 1,000 Hz
- Continuous current up to 200 mA, voltage drop up to 2 V
- Short-circuit and power-up pulse protection
IMF18-12NNSNC0S parameter table
| Parameter | Value |
|---|---|
| Part number | 1076668 |
| Thread / design | M18 x 1, standard design, 65 mm long |
| Installation | Non-flush |
| Sn / Sa | 12 mm / 9.72 mm |
| Thread length | 39 mm |
| Supply | 10 V DC to 30 V DC |
| Output | NPN, normally open, DC 3-wire |
| Switching frequency | 1,000 Hz |
| Connection | Male connector M12, 4-pin, gold-plated contacts |
| Sensing face | LCP plastic |
| Nuts | V4A stainless steel, 2 pieces |
| Enclosure rating | IP68, IP69K |
| Operating temperature | Minus 40 to plus 100 C |
| Tightening torque | Typically 90 Nm |
| MTTFD | 1,971 years |
How IMF18-12NNSNC0S differs from other IMF18 variants
Compared with the PNP twin IMF18-12NPONC0S, this code is NPN and normally open instead of PNP and normally closed. Compared with the IO-Link IMF18-08BPSNC0S it has 12 mm range instead of 8 mm, a non-flush head and a shorter 39 mm thread, and the datasheet shows no IO-Link block. The choice here is therefore about polarity and logic as well as range.
Use in the field
Examples are conveyors, fillers and cappers in beverage plants, gear detection in washed machine sections and position checks on valves of hygienic process lines. NPN output is common on equipment of Asian origin and on older panels, so this code is attractive for like-for-like replacement.
Selection
Check input polarity and logic before ordering: NPN normally open on this part. Allow free space around the non-flush head and choose a metal target of sufficient size. Use only the supplied V4A nuts or equivalent stainless fasteners so that the hygienic concept is not compromised.
Installation
Mount in a clean bore, tighten to the specified torque, set the working gap well inside the 9.72 mm safe sensing range and verify the visual adjustment indicator during commissioning.
Maintenance
Rinse and inspect the housing. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Many sensors in hygienic plants fail because of damaged cables and loosened plugs rather than electronics, so maintenance teams should check the M12 coupling regularly. The IMF18-12NNSNC0S uses gold-plated contact pins, which protect against corrosion in humid environments, but a poorly seated seal will still let water in. Use cordsets with the same level of ingress protection, for example IP68 and IP69K versions, and avoid mixing plugs of unknown quality. In your RFQ, quote IMF18-12NNSNC0S, part number 1076668, the required quantity and your delivery location in Oman or the GCC.
The datasheet also gives the reduction factors for different metals, so the working distance can be calculated for steel, aluminium or other targets, and it names a typical tightening torque of 90 Nm. Treat that as an upper reference and follow the bracket manufacturer’s limit if it is lower, because the stainless nuts bear on the machine frame, not on the sensor face.
Think about the commissioning sequence for the IMF18-12NNSNC0S as well. Wire the sensor to a sourcing NPN input, switch on the supply, and watch the visual adjustment indicator while bringing a steel target slowly towards the sensing face; the indicator tells the fitter when the target is detected at the nominal distance and when it is reliably inside the safe range. Repeat the movement from different angles if the part rotates or wobbles. Record the final working gap in millimetres on the maintenance sheet so that after a bracket repair the same setting can be restored without trial and error, which is far quicker than adjusting by feel.
Questions buyers ask about IMF18-12NNSNC0S
What range and installation does SICK IMF18-12NNSNC0S have? Sn is 12 mm and Sa 9.72 mm in a non-flush M18 x 1 housing, 65 mm long with a 39 mm thread.
What output does IMF18-12NNSNC0S have? NPN normally open on a DC 3-wire circuit via a 4-pin M12 male connector with gold-plated contacts.
What are the environmental ratings of IMF18-12NNSNC0S? IP68 and IP69K, resistance to cleaning agents, temperature range minus 40 to plus 100 degrees Celsius and V4A stainless nuts.
How strong is the vibration resistance of IMF18-12NNSNC0S? The datasheet lists 100 g for 2 ms over 500 cycles, 150 g for 1 million cycles, plus 10 to 55 Hz at 1 mm and 55 to 500 Hz at 60 g.
What is the reliability value of IMF18-12NNSNC0S? MTTFD is 1,971 years with DCavg of 0 percent and a mission time of 20 years.
Documents and quotation
The manufacturer datasheet for IMF18-12NNSNC0S is attached to this page. Send an RFQ with the part number IMF18-12NNSNC0S, quantity and delivery point in Oman or the GCC for availability and lead time.
Other Models in the Sick Imf18 Range
Seven Star LLC supplies models from the Sick Imf18 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| SICK IMF18-12NPONC0S IP69K Inductive Sensor, 12 mm, PNP NC | Inductive Proximity Sensors | View details |
| SICK IMF18-12NNSNC0S IP69K Inductive Sensor, 12 mm, NPN NO | Inductive Proximity Sensors | You are viewing this model |
Datasheets & Documents
- Datasheet SICK IMF18-12NNSNC0S IP69K Inductive Sensor, 12 mm, NPN NO Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
SICK is the German maker of industrial sensors: photoelectric and proximity sensors, safety laser scanners and light curtains, encoders, distance sensors, code readers and gas analysers. Erwin Sick, an optics engineer, founded it in Munich in 1946, and in 1952 it introduced its first marketable accident-prevention light curtain, which protected press operators by stopping the machine when a hand broke the light beam. The company moved to Waldkirch in the Black Forest in 1956 and is still headquartered there. It is a privately held company, and has been an Aktiengesellschaft (AG) since 1996.
SICK company profile
| Founded | 1946, Munich, Germany, by Erwin Sick (1909–1988) |
|---|---|
| Headquarters | Waldkirch, Baden-Württemberg, Germany (since 1956) |
| Ownership | Privately held; after the founder's death in 1988 his widow Gisela Sick became the main shareholder. Legal form SICK AG since 1996 |
| Size | More than 12,000 employees and group revenue of about EUR 2.3 billion (company figures for 2023) |
| First breakthrough | Accident-prevention light curtain for presses, shown in Hanover in 1952 |
| International growth | First foreign subsidiary in France in 1972, United States in 1976; today sales and service companies worldwide |
| Product families | Photoelectric, inductive, capacitive, magnetic and ultrasonic sensors; safety laser scanners, light curtains, safety controllers and relays; encoders and motor feedback systems; distance sensors and LiDAR; barcode and 2D code readers and machine vision; gas analysers, dust and flow measurement for process and emissions monitoring |
Milestones
- 1946: Erwin Sick receives a licence to run his engineering firm in Munich.
- 1952: The first marketable accident-prevention light curtain is presented in Hanover and goes into series production.
- 1956: The company moves to Waldkirch with 25 employees.
- 1972 and 1976: Subsidiaries are founded in France and the United States.
- 1996: SICK becomes an Aktiengesellschaft.
- Today: Sensors for factory and logistics automation, machine safety and process analysis, with a large share of revenue outside Germany.
Choosing a SICK sensor
For object detection, the sensing principle comes first. A retro-reflective sensor (WL series) sends light to a reflector and switches when an object breaks the beam; it is reliable over long distances and easy to align. A sensor with background suppression (WTB series) detects an object at a set distance and ignores what is behind it, which suits conveyors with shiny or dark backgrounds. A through-beam pair (WS/WE) gives the longest range and the highest reliability in dust. For transparent bottles and film, use a model built for transparent objects (for example WL12G-3B or WL150-P420). The digits in the code also matter: "P" usually means a PNP output and "N" NPN, and the last digits set the connector or cable. For machine guarding, a safety laser scanner such as nanoScan3 or microScan3 protects an area, while a safety controller such as Flexi Soft combines several safety devices.
Where SICK products are used
In Oman and the GCC, SICK sensors are used in packaging and bottling lines, food and beverage plants, logistics and airport baggage handling, cement and steel plants, ports and cranes, automated warehouses, and on machines built by European OEMs. SICK safety scanners guard robots and automated guided vehicles, and its encoders give position feedback on motors, hoists and conveyors.
SICK products we list
| Family | Examples |
|---|---|
| Photoelectric sensors | WL12-3P2431, WTB12-3P2431, GTB6-P4211, VL18-4P3240, WL12G-3B2531, WS/WE100, KT5W contrast, W26 IO-Link |
| Proximity, cylinder and ultrasonic sensors | IME12-08NPSZC0S, IME18-05BPSZC0S, MZT8, UM18 4-20 mA, UM30, UFN3 fork |
| Machine safety | nanoScan3, microScan3, S300 Professional, Flexi Soft FX3-CPU1, FX3-XTIO, ReLy OSSD |
| Encoders and motor feedback | DFS60B, AFM60 PROFINET, AFS60 SSI, ATM60 PROFIBUS, SRS50, EFS50 |
| Distance sensors and code readers | DT50, DL50, DT35, Lector632 |
Ordering SICK products: what we need
Send the type code and the 7-digit SICK part number from the label (for example WTB12-3P2431 together with its part number). For a replacement sensor, add the output (PNP or NPN), connection (M8, M12 or cable) and sensing distance. For encoders, add the interface (incremental, SSI, PROFIBUS, PROFINET), resolution and shaft type. For safety scanners, tell us the model and whether the existing configuration needs to be kept.
Frequently requested SICK models: SICK RT-P3231 ZoneControl Background Suppression Sensor.
Facts checked against SICK's published company history and annual figures, October 2026.
Browse SICK products by category: Sensors & Transmitters.
FAQ
Questions about the SICK IMF18-12NNSNC0S IP69K Inductive Sensor, 12 mm,
Answers from our engineering team on installation, compatibility and integration.
01What range and installation does SICK IMF18-12NNSNC0S have?
Sn is 12 mm and Sa 9.72 mm in a non-flush M18 x 1 housing, 65 mm long with a 39 mm thread.
02What output does IMF18-12NNSNC0S have?
NPN normally open on a DC 3-wire circuit via a 4-pin M12 male connector with gold-plated contacts.
03What are the environmental ratings of IMF18-12NNSNC0S?
IP68 and IP69K, resistance to cleaning agents, temperature range minus 40 to plus 100 degrees Celsius and V4A stainless nuts.
04How strong is the vibration resistance of IMF18-12NNSNC0S?
The datasheet lists 100 g for 2 ms over 500 cycles, 150 g for 1 million cycles, plus 10 to 55 Hz at 1 mm and 55 to 500 Hz at 60 g.
05What is the reliability value of IMF18-12NNSNC0S?
MTTFD is 1,971 years with DCavg of 0 percent and a mission time of 20 years.


















Reviews