- Automation & ControlView all 1,920 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Industrial Computers
- Motor Soft Starters
- Servo Drives
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Danfoss
Danfoss 017-140166 RT 116 Pressure Switch 1-10 bar
Description
Danfoss 017-140166 RT 116 pressure switch, 1 to 10 bar
The Danfoss 017-140166 is an RT 116 mechanical pressure switch with a regulation range of 1 to 10 bar and an adjustable differential from 0.33 to 1.3 bar. A bellows element moves a spindle against a set spring, and a single-pole changeover snap contact in an IP66 housing switches a pump, compressor, fan or alarm at the chosen pressure. Because it is purely mechanical and needs no auxiliary supply, the RT 116 remains a common choice for low-pressure circuits in marine, industrial and refrigeration plants. Seven Star LLC supplies the 017-140166 in Oman and the GCC as an independent supplier in Muscat.
The Danfoss product page lists 017-520366 as an identical product, so either code may appear in older documents or on drawings.
Decoding 017-140166 and the RT 116 type
| Element | Meaning |
|---|---|
| RT | Danfoss mechanical pressure and temperature control series for industrial and marine duty |
| 116 | Pressure type with 1 to 10 bar range (types 110, 112, 116, 117 and 121 cover other low and medium ranges) |
| 017-140166 | Danfoss code number of this RT 116 with G 3/8 male connection and SPDT switch |
| IP66 | Enclosure rating of the housing |
| SPDT | Single-pole changeover contact |
017-140166 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Danfoss 017-140166 (RT 116) |
| Regulation range | 1 to 10 bar g (14.5 to 145 psig) |
| Differential | 0.33 to 1.3 bar adjustable (4.8 to 18.9 psi) |
| Maximum working pressure | 22 bar g (320 psig) |
| Maximum test pressure | 25 bar g (363 psig) |
| Pressure element | Bellows |
| Pressure connection | G 3/8 male, ISO 228-1 |
| Contact system | Single-pole changeover (SPDT), snap action |
| Contact rating | AC-1 10 A 400 V; AC-3 4 A 400 V; AC-15 3 A 400 V; DC-13 12 W 220 V |
| Cable entry | 2 x Pg 13.5 for 6 to 14 mm cable |
| Enclosure | IP66 (IP54 on versions with external reset) |
| Ambient temperature | -50 to 70 °C |
| Terminal wiring | 0.2 to 2.5 mm² solid or flexible; 0.2 to 1.5 mm² with ferrules; tightening torque max 1.5 Nm |
| Net weight | 0.878 kg |
| Approvals listed for this code | BV, CCC, CE, CMIM, DNV, EAC, GL, KR, LR, LVD, NKK, RINA, RoHS, UA |
| Packing | Industrial pack of 12 |
How the RT 116 switches
The bellows is connected to the process through the G 3/8 port. Rising pressure compresses the bellows against a main spring whose preload is set by the front knob; the spindle moves a contact arm through a differential setting nut. The knob sets the lowest activation pressure on the scale, and the differential disc sets how far above that the contact must travel before it switches back, so the highest activation pressure equals the lowest value plus the differential. A snap function shears micro-welds between contacts and keeps the switch point independent of load current.
The RT family is designed so that the set point and differential stay constant as long as the housing is within its ambient limits, which are -50 to 70 °C. The data sheet also lists a media temperature window of -50 to 100 °C for the standard bellows version.
Where the 017-140166 fits among RT pressure switches
Within the RT range the 017-140166 sits in the low-pressure band. The RT 112 (for example 017-140266) covers 0.1 to 1.1 bar and the RT 200 (017-140066) covers 0.2 to 6 bar. The RT 5 (017-140866) covers 4 to 17 bar and the RT 117 covers 10 to 30 bar. Choosing the RT 116 means the working set point falls between 1 and 10 bar. Versions of the family with a neutral zone are marked with an L, such as the RT 110L, and are used for floating control with a variable frequency drive.
Selection and ordering checklist for RT 116
- Cut-in and cut-out pressures, converted to a lower setting plus differential inside 1 to 10 bar.
- Maximum working pressure of the system, which must stay below 22 bar g, with peaks below 25 bar g test pressure.
- Medium: check the wetted materials against the material table in the data sheet; the manufacturer points to diaphragm switches rather than bellows types for seawater and strongly pulsating media.
- Connection: G 3/8 male; other codes in the range use a cutting ring or a weld nipple.
- Electrical load against the AC-3 and AC-15 ratings, and the need for gold-plated or manual-reset contact sets, which are separate accessories.
- Marine or class approvals required on the project certificate.
Installation and commissioning
Two fixing holes become accessible when the front cover is removed. The switch can be installed in any position, though on plant with strong vibration it is better to have the cable entry facing downwards. Hold the spanner flats on the pressure connection when fitting a line, so that torque does not reach the bellows. On steam plant insert a water-filled loop to protect the element from temperature above 150 °C in the medium, and with pulsating pressure fit a damping coil. When the set value is changed, use the scale as a guide only and verify the actual switch points with a test gauge.
Typical applications of the 017-140166 in Oman and the GCC
An RT 116 appears on compressed air receivers, cooling-water and fresh-water pressure sets, lube-oil and fuel-oil circuits and small boiler feed systems at oil and gas, power and desalination sites, and on ship and workboat systems along the Omani coast. High ambient temperature is rarely a problem because the housing is rated to 70 °C; the more common issues are dust ingress on cable entries and moisture, which the IP66 rating and correctly fitted Pg 13.5 glands address.
Low and medium pressure RT switches compared
| Type | Range bar g | Differential bar | Code |
|---|---|---|---|
| RT 112 | 0.1 to 1.1 | 0.07 to 0.16 | 017-140266 |
| RT 200 | 0.2 to 6 | 0.25 to 1.2 | 017-140066 |
| RT 116 | 1 to 10 | 0.33 to 1.3 | 017-140166 |
| RT 5 | 4 to 17 | 1.2 to 4 | 017-140866 |
Information to send with an RFQ for 017-140166
- Code 017-140166 and quantity.
- Required set point and differential, and the pressure unit used on site.
- Medium, temperature and pulsation level.
- Electrical voltage, current and contact type.
- Class or marine approval needs.
Documents and quotation
The Danfoss RT pressure switch data sheet is attached on this page, with the ordering tables, material list and setting notes.
Send the code 017-140166 with your set points and we will confirm availability and a quotation for Oman and the GCC.
Datasheets & Documents
- Datasheet Danfoss 017-140166 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
FAQ
Questions about the Danfoss 017-140166 RT 116 Pressure Switch 1-10 bar
Answers from our engineering team on installation, compatibility and integration.
01What is the pressure range of the Danfoss 017-140166?
It is an RT 116 with a regulation range of 1 to 10 bar g and an adjustable differential of 0.33 to 1.3 bar.
02What are the maximum working and test pressures?
The maximum working pressure is 22 bar g and the maximum test pressure is 25 bar g.
03What pressure connection does it have?
A G 3/8 male thread to ISO 228-1, with a bellows pressure element.
04What contact does the RT 116 use?
A single-pole changeover (SPDT) snap contact rated AC-1 10 A 400 V and AC-15 3 A 400 V, in an IP66 housing with two Pg 13.5 cable entries.
05Which temperatures can it withstand?
The housing ambient range is -50 to 70 degrees C and the data sheet gives a media range of -50 to 100 degrees C for the standard version.


















Reviews
There are no reviews yet.