- Automation & ControlView all 1,803 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Isolator & Barrier
- Encoders
- HMI Displays
- Industrial Computers
- Servo Drives
- Motor Soft Starters
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Endress+Hauser (E & H)
Endress+Hauser PMD55B Deltabar Differential Pressure Transmitter
Description
Endress+Hauser PMD55B Deltabar differential pressure transmitter
The Endress+Hauser PMD55B is a digital differential pressure transmitter with a metallic process membrane, built for differential pressure, level and flow measurement in liquids and gases. It belongs to the newer B generation of Deltabar devices: HART or PROFINET over Ethernet-APL, optional Bluetooth, a large display with wizard-based commissioning, and optional Heartbeat Technology for verification and monitoring. Seven Star LLC supplies the PMD55B in Oman and the GCC as an independent supplier based in Muscat.
The datasheet lists differential ranges up to 40 bar (600 psi), static pressures up to 250 bar (3 750 psi) and reference accuracy up to ±0.055 %, so the PMD55B is positioned as the high-performance transmitter in the Deltabar line for orifice flow, filter monitoring and hydrostatic level in pressurised vessels.
PMD55B technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser PMD55B (Deltabar) |
| Measured variable | Differential pressure; level, volume, mass and flow derived from it |
| Measuring cells | 10, 30, 100, 500 mbar and 3, 16, 40 bar (0.15 to 600 psi), measured both directions around zero |
| Static pressure (MWP) | PN 160: 160 bar (2 400 psi), 100 bar on the two smallest cells; PN 250: 250 bar (3 626 psi), both sides loaded |
| Reference accuracy | Standard: ±0.1 % (10 and 30 mbar), ±0.075 % (100 mbar and above); Platinum: ±0.055 % (100 mbar and above) |
| Turn down | Up to 100:1 standard, 10:1 with Platinum; higher values on request or at the device |
| Long-term stability | 500 mbar and above: ±0.05 % of URL in 1 year, ±0.23 % over 10 years |
| Response | Dead time max. 50 ms; T63 max. 85 ms and T90 max. 200 ms on cells of 500 mbar and above; warm-up 5 s or less |
| Process temperature at transmitter | –40 to +85 °C; manifold up to 110 °C |
| Ambient temperature | –40 to +85 °C (display usable without limitation from –20 to +60 °C) |
| Outputs | 4 to 20 mA with HART; PROFINET over Ethernet-APL (10BASE-T1L, 10 Mbit); optional Bluetooth |
| Supply voltage | 10.5 to 35 V DC (10.5 to 30 V DC Ex i) for HART |
| Membrane materials | 316L (1.4435) or Alloy C276, optional 25 µm gold coating |
| Seals and fill fluid | PTFE, FKM, EPDM or FFKM seals; silicone oil or inert oil |
| Degree of protection | IP66/68 and Type 4X/6P |
| Functional safety | 4 to 20 mA devices developed to IEC 61508 for monitoring up to SIL 3 (Functional Safety Manual) |
Data are from the Endress+Hauser Technical Information for the Deltabar PMD55B. Pressure limits on a given device depend on the lowest-rated element of the ordered process connection and seal.
How the PMD55B measures differential pressure
Both process pressures act on separate metallic membranes. The fill fluid transmits each pressure to the middle diaphragm of a silicon measuring element, which deflects in proportion to the difference p1 minus p2, and a resistance bridge turns that deflection into an electrical signal. The cell body and side flanges are 316L, with cast 316/316L or, on coplanar versions, Super Duplex side flanges for seawater service. Vent valves are built in.
For flow the PMD55B reads the differential pressure across an orifice plate or pitot tube, and its low-flow cut-off parameter (5 % by default in square root mode) holds the output at zero near no-flow so noise does not appear as flow. For level in a closed vessel, the device measures the hydrostatic difference between the bottom tapping and the reference leg. The linearisation function converts height into volume or mass.
PMD55B mounting orientations and side flange options
| Order option | Piping arrangement |
|---|---|
| A | Horizontal piping, high pressure on the screw-head side, with side vent |
| D | Horizontal piping, high pressure on the nut side, with side vent |
| G | Vertical piping, high pressure on the screw-head side, vent |
| K | Universal side flange, high pressure on either side, with vent |
| N | Process connection at the bottom, high pressure on the left, for mounting on existing manifolds |
Process connections are 1/4-18 NPT with IEC 61518 UNF 7/16-20 mounting, DIN 19213 M10 or M12 mounting, Rc 1/4 installation, or coplanar-compatible and coplanar IEC arrangements. The flange raised face has the same material as the membrane. Choose PTFE seals for aggressive media and FKM or EPDM for general service.
Where the PMD55B fits in the Deltabar family
Within the current Endress+Hauser Deltabar line the PMD50 is the lower-cost HART-only transmitter with accuracy up to ±0.05 % when specified as Platinum, and the PMD63B is the diaphragm seal version with capillaries or a temperature isolator for hot or sticky media. The PMD55B sits between them: it adds PROFINET with Ethernet-APL, Bluetooth, Heartbeat Technology and a wider choice of membrane materials and seals. For a single-ended pressure measurement the equivalent models are the Cerabar PMP55 and PMP63B.
PMD55B selection and ordering checklist
- Range: pick the cell that covers the maximum differential pressure and keep the turn down within the accuracy specification.
- Static pressure: choose PN 160 or PN 250 and check negative-side limits, because the 40 bar cell tolerates only 100 bar on the low side.
- Wetted materials: 316L or Alloy C276 membrane, optional gold coating, and the seal material.
- Output and communication: HART or PROFINET over Ethernet-APL, with or without Bluetooth.
- Process connection and orientation: codes A, D, G, K or N, thread type, vent and drain arrangement.
- Housing and approvals: single or dual-compartment housing and the required Ex protection (ATEX, UKCA, CSA, NEPSI, INMETRO, KC, EAC, JPN).
- Software: Heartbeat Technology and Bluetooth if proof testing and remote setting are wanted.
PMD55B installation, commissioning and maintenance
For gas flow, mount the transmitter above the tapping points so condensate runs back into the pipe. For steam, mount below the tapping points and use condensate pots at the same height as the taps. Use a three-valve or five-valve manifold so the device can be isolated and zeroed in service. With a manifold, keep in mind the 110 °C process limit and, above 85 °C, the reduced allowed ambient temperature.
Perform a zero trim with both sides at the same pressure, then verify the range with a calibrator. The warm-up time is five seconds or less. Heartbeat Verification gives a documented pass or fail check without removing the device from the loop, which cuts shutdown work on safety-related loops. Replace the process seals when the device is opened, and note the minimum static pressure of 25 mbar abs at reference conditions with silicone oil.
Typical PMD55B applications in Oman and the GCC
In Oman and the GCC the PMD55B is applied on orifice-plate flow measurement in oil and gas gathering, fuel gas and flare lines, differential pressure across strainers, filters and coalescers, level in pressurised separators and boiler drums, and pump and compressor protection in power and desalination plants. The Super Duplex coplanar option is relevant to seawater cooling and injection lines. In hot desert installations use sunshades and keep impulse lines insulated, and in coastal plants specify corrosion protection for the housing.
Information to send with a PMD55B RFQ
- Part number PMD55B and the full order code from the nameplate if you are replacing a unit.
- Differential pressure range, static pressure and temperature, and the medium (gas, steam or liquid).
- Measurement task: flow with orifice or pitot, level, or filter monitoring.
- Wetted materials, seal material and process connection orientation.
- Output (HART or PROFINET), Ex approval, housing, manifold needs and quantity.
Documents and quotation
The Endress+Hauser Technical Information for the Deltabar PMD55B is attached on this page, with ranges, performance data and the ordering structure.
Send us the PMD55B details above and Seven Star LLC will prepare a quotation for Oman and the GCC.
Datasheets & Documents
- Datasheet Endress+Hauser PMD55B Technical Information Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser PMD55B Deltabar Differential
Answers from our engineering team on installation, compatibility and integration.
01What is the PMD55B used for?
It measures differential pressure and from it flow across an orifice plate or pitot tube, filter or strainer pressure drop, and hydrostatic level in pressurised vessels. It has a metallic process membrane and can handle static pressures up to 250 bar.
02What accuracy and turn down does the PMD55B reach?
Standard devices reach ±0.075 % reference accuracy from the 100 mbar cell upward, and the Platinum version ±0.055 %. The 10 mbar and 30 mbar cells are rated ±0.1 %. Turn down is up to 100:1, or up to 10:1 for Platinum.
03Which communication options does the PMD55B have?
4 to 20 mA with HART, and PROFINET over Ethernet-APL using 10BASE-T1L. Bluetooth is optional for local and remote operation, and the Heartbeat Technology package can be added for verification and monitoring.
04What static pressure rating does the PMD55B have?
The PN 160 version has a maximum working pressure of 160 bar and the PN 250 version 250 bar with pressure on both sides. If the 40 bar cell is loaded on the negative side only, the MWP is limited to 100 bar.
05How does the PMD55B differ from the PMD50?
The PMD55B offers PROFINET and Bluetooth options and cells from 10 mbar, with accuracy up to ±0.055 %. The PMD50 is a HART-only device with a 100 mbar to 40 bar range and accuracy up to ±0.05 % in the Platinum version.


















Reviews