Brand:

Turck LS-551-0700-LIU24PN8X-H1181 Level Sensor

Description

Cuttable-probe level sensor with analog and four switching outputs

The Turck LS-551-0700-LIU24PN8X-H1181 is a liquid level sensor from the LS-5 series with a 700 mm probe. Turck says the series uses time-of-flight measurement of electromagnetic waves, so no moving parts are involved, and that the sensor is resistant to deposit formation and can be commissioned without calibration.

One sensor gives both continuous level monitoring and point level switching: an analog output of 4 to 20 mA or 0 to 10 V, a PNP output or IO-Link, and three further PNP/NPN switching outputs. The probe can be cut to length to fit a vessel, which keeps the number of variants small.

Technical specifications of the LS-551-0700-LIU24PN8X-H1181

Parameter Specification
Manufacturer Turck
ID 100001870
Application Liquids
Probe length 700 mm; maximum probe loading 6 Nm
Probe accuracy 5 mm
Hysteresis / repeatability At least 2 mm / 2 mm or better
Inactive area 25 mm at the process connection; 10 mm at the probe end
Dielectric constant 5 or higher; 1.8 or higher with coaxial tube accessory
Medium temperature -20 … +100 °C
Pressure resistance -1 … 10 bar
Operating voltage / current 12 … 30 VDC / up to 100 mA
Output 1 Analog, 4 … 20 mA or 0 … 10 V (automatic switching by load)
Output 2 IO-Link or PNP switching output
Outputs 3, 4 and 5 Switching, PNP/NPN
Response time Typically below 400 ms
IO-Link V1.1, class A, COM2 (38.4 kbaud)
Process connection G3/4 inch male thread
Materials in contact with medium Stainless steel 1.4404 (AISI 316L), PTFE, FKM
Protection class / ambient IP67 / -20 … +60 °C
MTTF 194 years
Approvals UL

Turck also quotes the process limits in US units, a temperature to 212 degrees F and pressure to 145 psi. The data sheet lists a PBT housing, aramid-fibre sealing bound with NBR, a temperature drift of 0.1 or less, short-circuit and reverse polarity protection, an inductive load limit below 1 H and a capacitive load limit of 100 nF, with insulation class III.

Where the sensor fits

Turck lists coaxial tubes as an accessory for non-metallic tanks and for low dielectric media, which extends the application range where the dielectric constant is as low as 1.8. The small inactive areas make the probe suitable for small containers.

The compact display housing is rotatable and the sensor is set up with four buttons and the integrated display or through IO-Link. Typical uses are lubricant, coolant, condensate and chemical tanks on skids and packaged equipment.

Selecting and installing the sensor

Check the dielectric constant of the liquid and the process temperature and pressure against the limits of minus 20 to plus 100 degrees C and minus 1 to 10 bar. Allow for the 25 mm inactive area at the connection when setting the high level switch point.

Keep the probe clear of vessel internals and respect the 6 Nm loading limit when tightening the G3/4 thread. This is a general industrial sensor with a UL listing and is not marked for hazardous areas.

Documents and quotation

The attached document is the Turck data sheet for the LS-551-0700-LIU24PN8X-H1181. Instructions for use and IO-Link parameter documents are published separately by Turck.

For a quotation, send the probe length, vessel details, medium and quantity. See Level Instrumentation for related instruments.

Datasheets & Documents
  • PDF Datasheet Turck LS-551-0700-LIU24PN8X-H1181 Level Sensor data sheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Turck sensor type codes look cryptic, yet each block of letters and digits describes the part. Founded in 1965 and based in Mülheim an der Ruhr, Germany, the company makes sensors, connectors, I/O and interface devices for factory and process automation. Seven Star LLC lists the Turck BI5-M18-AP6X-H1141 inductive proximity sensor and the CMVT-QR20 vibration and temperature sensor, and supplies Turck sensors in Oman and the GCC.

Turck sensors listed here

In BI5-M18-AP6X-H1141, BI is a flush-mountable inductive sensor, 5 is the rated switching distance in millimeters and M18 is the threaded barrel. AP6X is a three-wire DC output, PNP normally open, and H1141 is the M12 connector. The CMVT-QR20 is a small rectangular sensor that measures vibration together with temperature and reports both over IO-Link for condition monitoring.

Ordering Turck sensors: what we need

Send the full type code and the ID number printed on the sensor or its bag label. If the label is lost, give the housing size, flush or non-flush mounting, output type, supply voltage and connection.

Frequently Asked Questions

What technology does the LS-551 use?
Time-of-flight measurement of electromagnetic waves along the probe, with no moving parts.
What outputs does it have?
One analog output (4 to 20 mA or 0 to 10 V), one IO-Link or PNP output and three PNP/NPN switching outputs.
Can the probe be shortened?
Turck describes the probes as cuttable to length, which enables quick integration into most applications.
What liquids can it measure?
Liquids with a dielectric constant of 5 or higher, or 1.8 or higher with the coaxial tube accessory.
What is the probe accuracy?
Plus or minus 5 mm, with repeatability of 2 mm or better.