Brand:

Rosemount 5400 Two-Wire Non-Contacting Radar Level Transmitter

Description

Overview

The Rosemount 5400 is Emerson’s two-wire non-contacting radar level transmitter, which the product data sheet describes as easy to install and virtually unaffected by process conditions. It is offered in two frequency versions: the Rosemount 5402, a high-frequency radar at about 26 GHz that is the preferred choice for most liquid and many solids applications, and the Rosemount 5401, a low-frequency radar at about 6 GHz designed for tough conditions with turbulence, foam, condensation and deposits. The Rosemount 5400 has a large installed base on storage tanks, reactors and silos, and is supported with HART, FOUNDATION Fieldbus and Modbus electronics.

Seven Star LLC supplies the Rosemount 5400 to refineries, petrochemical plants, utilities, mining and cement operations, and EPC contractors in Oman and the GCC, from our office in Muscat. Many plants in the region standardised on this transmitter in earlier project phases, so like-for-like supply helps maintenance teams keep spare parts, configuration files and training consistent.

Measurement Principle

According to Emerson, the Rosemount 5400 measures the distance to the surface with short radar pulses. When a pulse reaches the medium, part of the energy is reflected back to the transmitter, and level, volume and level rate are calculated from the time difference between the transmitted and the reflected pulse. Turbulence, foam and long measuring ranges can reduce the reflected energy, so Emerson uses a dual port technology that helps detect the surface in challenging applications.

The data sheet lists the benefits of the non-contacting method: no compensation is needed for changing process conditions, there are no moving parts and no recalibration is required, and the technology is ideal for dirty, coating and corrosive applications. As general engineering context, the choice between the two versions is mainly about beam width and robustness: the 26 GHz Rosemount 5402 produces a narrow beam that fits valves, taller nozzles and smaller openings, while the 6 GHz Rosemount 5401 uses a wider beam that is more tolerant of condensation, vapour, dust and build-up on the antenna.

Engineering Design of the Rosemount 5400

The Rosemount 5400 has a robust, shock-resistant and vibration-proof design with a detachable head that allows the tank to remain sealed during maintenance. Circular polarisation minimises installation constraints. Antenna options include stainless steel cone antennas from 2 inch to 8 inch, a condensation-resistant process seal antenna and, for the Rosemount 5402, a parabolic antenna with a 4.5° beam for long-range and solids duties. The data sheet gives beam angles such as 19° for the 2 inch cone and 9° for the 4 inch cone on the 5402, compared with 37° for the 4 inch cone on the 5401.

The 4–20 mA HART version is loop powered from 16 to 42.4 Vdc (16 to 30 Vdc in intrinsically safe applications), and the HART signal can feed a Rosemount 333 HART Tri-Loop for up to three additional analogue outputs or a Wireless THUM Adapter for WirelessHART access to diagnostics. FOUNDATION Fieldbus and Modbus versions are also offered. Process temperature and pressure depend on the antenna and seal; the cone antenna is rated up to 16 bar and 150 °C at the flange, and the parabolic antenna is rated for -0.5 to 0.5 bar up to 200 °C.

Key Features

The Rosemount 5400 data sheet highlights the following features.

  • Dual port technology improves reliability with disturbing factors and longer measuring ranges.
  • Two frequency versions, 26 GHz (5402) and 6 GHz (5401), match narrow-beam or rugged duty requirements.
  • Instrument accuracy is 3 mm for the 5402 and 10 mm for the 5401 at reference conditions.
  • A maximum measuring range of 35 m from the flange covers tall storage tanks and silos.
  • Condensation- and dirt-resistant antennas maximise uptime in difficult vapour spaces.
  • A detachable head allows electronics service while the tank remains sealed.
  • HART, FOUNDATION Fieldbus and Modbus outputs ease plant integration, with Tri-Loop and THUM options.
  • A diagnostics suite with Signal Quality Metrics helps detect antenna contamination or loss of signal strength.

Industrial Applications

Emerson lists storage and buffer tanks, reactor and mixing tanks and solids measurement as core applications for the Rosemount 5400, noting that the 5402 with a 4 inch cone or parabolic antenna suits silos with rapid level changes because the narrow beam avoids internal obstructions. In Oman this matches crude and product tanks at refineries, sour water and amine tanks at gas plants, chemical reactors and blend tanks in Sohar, cement and clinker silos, and storage at desalination and power plants. The low-frequency Rosemount 5401 is a common choice where heavy condensation or foam is expected. Because both versions share the same housing concept, electronics options and configuration tools, a site can keep one family of radar transmitters across clean storage, dirty process and bulk solids duties, which simplifies spare parts, training and documentation for the maintenance team.

Seven Star LLC supplies the Rosemount 5400 throughout the Sultanate of Oman and the GCC, and can help customers decide between it and newer Rosemount radar designs. Related instruments include the Rosemount 5408 non-contacting radar level transmitter, the Rosemount 5300 guided wave radar level transmitter for interface and low-dielectric duties, and the Rosemount 2140 vibrating fork level detector for independent point level alarms.

Technical Specifications

The following Rosemount 5400 data is taken from Emerson product data sheet 00813-0100-4026.

Parameter Specification
Model Rosemount 5400 Level Transmitter (5401 low frequency, 5402 high frequency)
Measuring principle Pulsed non-contacting radar
Frequency Approx. 6 GHz (5401); approx. 26 GHz (5402)
Instrument accuracy 5402: 3 mm; 5401: 10 mm (reference conditions)
Repeatability 1 mm at 5 m distance
Resolution 1 mm
Maximum measuring range 35 m from flange (depends on frequency, antenna, dielectric constant and process)
Minimum dielectric constant 1.4
Update interval One second
Output 4–20 mA HART; FOUNDATION Fieldbus; Modbus
Supply voltage (HART) 16 to 42.4 Vdc (16 to 30 Vdc IS)
Microwave output power Below 1 mW
Ambient temperature -40 to 80 °C (non-hazardous, HART); limits vary with certification
Damping 0 to 60 s (2 s default)

How to Order

To order the Rosemount 5400, send Seven Star LLC an RFQ with the product, tank height, nozzle size, pressure and temperature, required output and certification, or the full model code of an existing unit for like-for-like replacement. The Emerson product data sheet can be downloaded from this page. Seven Star LLC supplies Rosemount radar transmitters from Muscat across Oman and the GCC, with sourcing and model selection support.

Datasheets & Documents
  • PDF Datasheet Emerson Rosemount 5400 Level Transmitter Product Data Sheet (00813-0100-4026) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rosemount is Emerson's brand for pressure, temperature, level and flow measurement, best known for the 3051 pressure transmitter. Frank Werner, Robert Keppel and Vernon Heath founded it in Minnesota in 1956 as Rosemount Engineering Company, first making temperature sensors for aerospace. It moved into the process industries, took the name Rosemount Inc. in 1966, and has been part of Emerson since 1976.
Seven Star LLC is an independent supplier in Muscat. We list Rosemount transmitters, level instruments, flowmeters and analytical sensors, and supply them and their spares to oil and gas, power, water and process plants in Oman and the GCC by model code.
Rosemount company profile

Established1956, Minnesota, USA, as Rosemount Engineering Company
FoundersFrank D. Werner, Robert E. Keppel and Vernon H. Heath
OwnershipAcquired by Emerson in 1976; now an Emerson brand
Product familiesPressure, DP flow and level transmitters, temperature sensors and transmitters, radar and guided wave radar level, vibrating fork switches, tank gauging, magnetic, vortex and ultrasonic flowmeters, liquid analysis sensors and wireless instruments

Milestones

1956: Robert Keppel, Vernon Heath and Frank Werner incorporate Rosemount Engineering Company in Minnesota; early work is aerospace sensors.
1969: The Rosemount 1151 analog pressure transmitter is introduced.
1976: Emerson acquires Rosemount.
1989: The Rosemount 3051 pressure transmitter, built on digital technology, is launched.
2001: The 3051S generation follows.

Rosemount products we list

FamilyModelsTypical use

Pressure transmitters3051, 3051C coplanar, 3051T in-line, 3051S, 3051S series, 3051SMV multivariable, 2051, 2088, 1199 diaphragm sealsPressure, differential pressure and remote seal measurement
DP flow and DP level3051CF flowmeter, 3051L, 3051SALFlow through primary elements, and level in pressurised vessels
Temperature644, 248, 3144P, 848T, 648 wireless, 214C RTD sensor, 2240S multi-inputProcess temperature, high-density multipoint and tank temperature
Radar and level5408, 5400, 5300 GWR, 3300 GWR, 3308A wireless, 5900S, 5900C tank gaugesLevel in tanks, separators and custody transfer tank gauging
Level switches2120, 2140, 2160 wireless, 702 discrete transmitterHigh and low level alarms, overfill protection and pump protection
Flowmeters8700 magnetic, 8800D vortex, SeniorSonic 3414, 3415/3416, 3417, JuniorSonic 3411/3412, 3814 liquidWater, steam and gas flow, and fiscal gas and liquid metering
Liquid analysis396P TUpH, 396PVP, 499ACL chlorine sensorpH, ORP and free chlorine in water and process streams

Many Rosemount transmitters share one platform, so the model code tells you what you have. On a 3051, the letter after the number sets the type: C for coplanar (differential or gauge), T for in-line, L for liquid level and CF for a complete flowmeter. The next characters set the measurement type, the range code, the output (4-20 mA HART, FOUNDATION Fieldbus or WirelessHART) and the wetted materials. A transmitter with the wrong range code may work, but with poor accuracy at the point that matters.
Where Rosemount instruments are used
In Oman and the GCC, Rosemount instruments are used across upstream oil and gas, gas plants and LNG, refineries, tank farms and terminals, power and desalination stations, and water networks. Ultrasonic gas meters and tank gauges are used for fiscal and custody transfer measurement.
Ordering Rosemount instruments: what we need
Send the full model code from the nameplate (for example 3051CD2A22A1AM5B4) and the tag if it is a replacement. For a new instrument, send the measuring range, process connection, wetted materials, output protocol and hazardous area approval.
Facts checked against Emerson's Rosemount history and published company histories, October 2026.
Browse Rosemount products by category: Pressure Instrumentation, Temperature Instrumentation, Level Transmitter, Liquid Analysis Sensors, Flowmeters.

FAQ

Questions about the Rosemount 5400 Two-Wire Non-Contacting Radar Level

Answers from our engineering team on installation, compatibility and integration.

01What is the difference between the Rosemount 5401 and 5402?
The Rosemount 5402 is the high-frequency version at about 26 GHz with a narrow beam and 3 mm accuracy, preferred for most applications. The Rosemount 5401 is the low-frequency version at about 6 GHz with 10 mm accuracy, suited to turbulence, foam, condensation and deposits.
02What measuring range does the Rosemount 5400 cover?
The maximum measuring range is 35 m from the flange, depending on frequency, antenna size, the dielectric constant of the liquid and process conditions. The minimum dielectric constant is 1.4.
03Which outputs are available for the Rosemount 5400?
The Rosemount 5400 is offered with 4-20 mA HART, FOUNDATION Fieldbus and Modbus electronics. HART units can be combined with a Rosemount 333 HART Tri-Loop or a Wireless THUM Adapter.
04Can the Rosemount 5400 measure solids?
Yes. Emerson recommends the Rosemount 5402 with a 4 inch cone or parabolic antenna for a broad range of solids applications, including silos with rapid level changes.
05Does Seven Star LLC supply the Rosemount 5400 in Oman?
Yes. Seven Star LLC supplies the Rosemount 5400 from Muscat to customers in Oman and the GCC, including like-for-like replacements, with sourcing and model selection support.