Brand:

Yokogawa EJX530A-JCH4N-032EL Hastelloy Gauge Pressure

Description

Hastelloy build of EJX530A-JCH4N-032EL

Yokogawa EJX530A-JCH4N-032EL is a C capsule gauge pressure transmitter spanning 0.1 to 10 MPa in which every wetted part, connector, diaphragm and others, is Hastelloy C-276. The connection is 1/2 NPT female, the housing is the corrosion-resistant cast aluminum (code 3), the indicator carries the range-setting push button (code E) and a 316 SST two-inch pipe bracket is included. Output is 4 to 20 mA with HART.

Suffix of EJX530A-JCH4N-032EL decoded

Code position Meaning
-J 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering)
C Capsule: span 0.1 to 10 MPa
H Hastelloy C-276 for process connector, diaphragm and other wetted parts
4 Process connection: 1/2 NPT female
3 Amplifier housing: cast aluminum alloy with corrosion resistance properties
2 Electrical: 1/2 NPT female, two electrical connections, no blind plugs
E Integral indicator: digital indicator with range-setting push button
L Mounting bracket: 316 SST 2-inch pipe mounting bracket

Why Hastelloy and what the datasheet says about it

For EJX530A-JCH4N-032EL the wetted-parts code H replaces the standard 316L connector with Hastelloy C-276, so the connector, diaphragm and other wetted parts all use the same alloy. Yokogawa marks the selected materials as conforming to NACE MR0175/ISO 15156 and MR0103. At the same time the datasheet states that material selection is the responsibility of the user and that highly corrosive fluids, with hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite and steam at 150 degrees C or above named as examples, require a check with the manufacturer. The process temperature limit of minus 40 to 120 degrees C applies regardless of material, and fill fluid is silicone oil unless the fluorinated oil option is selected. In practice this means Hastelloy is a deliberate choice for specific chemistry, not a blanket upgrade for every service.

Rating summary

Upper range limit and maximum working pressure are 10 MPa (1450 psig); over-pressure is 20 MPa and burst is 30 MPa. Reference accuracy is plus or minus 0.04 percent of span for spans of 1 MPa and above, and stability is plus or minus 0.1 percent of URL for 15 years. The materials are shown by Yokogawa as conforming to NACE MR0175/ISO 15156 and MR0103 recommendations.

Output, diagnostics and safety data of EJX530A-JCH4N-032EL

Output is 3.6 to 21.6 mA, linear or square root, with failure alarms at 110 percent or minus 5 percent. Standard EJX-series transmitters with HART or BRAIN are certified for SIL 2 capability in single use and SIL 3 in dual use under IEC 61508, according to the datasheet. Parameters such as loop test, tag number, unit, LRV, URV, damping, output mode and display content are set locally with the external zero screw and push button. The 10-segment signal characterizer, process high and low alarm, and the self-diagnostics for CPU, hardware, configuration and capsule temperature are inside the standard amplifier. For the EJX series, an optional status output (/AL) is a transistor sink output rated 30 V DC at 120 mA maximum, and the multi-sensing option /DG6 applies to HART and fieldbus output codes.

Ambient limits are minus 40 to 85 degrees C, narrowed to minus 30 to 80 degrees C with the LCD. Weight is 1.2 kg for A, B and C capsules, before indicator and bracket.

Data table for EJX530A-JCH4N-032EL

Item Value
Capsule C 0.1 to 10 MPa gauge
Wetted parts Hastelloy C-276 throughout
Connection 1/2 NPT female
Housing 3 Cast aluminum with corrosion resistance; copper 0.03 percent or less, iron 0.15 percent or less
Indicator E, with range-setting push button
Bracket L, 316 SST for 2-inch pipe
Output 4 to 20 mA, HART 5/7
Response 90 ms
Burst pressure 30 MPa

Typical services

Process lines where 316L is questionable: acidic condensate, wet sour gas, brine and some chemical injection. The 10 MPa capsule suits pump discharge pressure on these services. Check the datasheet warnings before using Hastelloy with strong oxidizing media.

Housing 3 and entries

Housing code 3 is not combined with electrical codes 0, 5, 7, 9 and A; electrical code 2 is valid. Compared with the standard housing 1, it offers better corrosion resistance at the same weight class; compared with the stainless housing 2 it is lighter by 1.5 kg.

Install and set up EJX530A-JCH4N-032EL

Mount the bracket on a 2-inch pipe, connect the 1/2 NPT female thread, wire through one entry and then use the push button to set LRV and URV with a pressure source. Confirm display variables and damping.

Flush the line before removal if the process is corrosive, inspect the connector face for pitting and verify zero at each turnaround.

Quick answers about EJX530A-JCH4N-032EL

  • Which wetted material does EJX530A-JCH4N-032EL use? Hastelloy C-276 for the process connector, diaphragm and other wetted parts.
  • What span does the C capsule give? 0.1 to 10 MPa gauge, with a lower range limit of minus 0.1 MPa.
  • What does housing code 3 mean? Cast aluminum alloy with corrosion resistance properties.
  • Can I set the range locally? Yes, the E indicator includes a range-setting push button.
  • Is a bracket supplied? Yes. L is a 316 SST two-inch pipe bracket.

Documents and quotation

State the process medium and the pressure range in your RFQ.

The Yokogawa general specification GS 01C25F01-01EN, which covers the EJX510A and EJX530A, is supplied as the datasheet PDF with this listing. To request a quotation, send the part number EJX530A-JCH4N-032EL, the quantity, tag numbers, process fluid and the approval you need if the area is classified. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Availability and lead time are confirmed per RFQ.

Delivery to Sites in Oman and the GCC

Delivery of the Yokogawa EJX530A-JCH4N-032EL is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive pressure transmitters equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.

Other Models in the EJX530A Range

Seven Star LLC supplies models from the EJX530A range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa EJX530A-DAS4N-012NN Gauge Pressure TransmitterPressure TransmittersView details
Yokogawa EJX530A-JBS8N-012DL Gauge Pressure, G1/2 MalePressure TransmittersView details
Yokogawa EJX530A-JCH4N-032EL Hastelloy Gauge PressurePressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa EJX530A-JCH4N-032EL Hastelloy Gauge Pressure Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJX530A-JCH4N-032EL Hastelloy Gauge

Answers from our engineering team on installation, compatibility and integration.

01Which wetted material does EJX530A-JCH4N-032EL use?
Hastelloy C-276 for the process connector, diaphragm and other wetted parts.
02What span does the C capsule give?
0.1 to 10 MPa gauge, with a lower range limit of minus 0.1 MPa.
03What does housing code 3 mean?
Cast aluminum alloy with corrosion resistance properties.
04Can I set the range locally?
Yes, the E indicator includes a range-setting push button.
05Is a bracket supplied?
Yes. L is a 316 SST two-inch pipe bracket.