Brand:

Yokogawa EJA510E-JDH4N-022EL Hastelloy Absolute Pressure

Description

The high-pressure end: EJA510E-JDH4N-022EL

This is the toughest member of the EJA510E trio. Yokogawa EJA510E-JDH4N-022EL combines the D capsule, with a span window of 0.5 to 50 MPa absolute, with Hastelloy C-276 for every wetted part and an ASTM CF-8M stainless steel amplifier housing. A 316 SST two-inch pipe bracket and a digital indicator with push-button range setting complete the package. It is the specification you pick when pressure is high, the process is aggressive and the plant is by the sea.

Suffix JDH4N-022EL decoded

Code position Meaning
-J 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering)
D Capsule: span 0.5 to 50 MPa
H Hastelloy C-276 for process connector, diaphragm and other wetted parts
4 Process connection: 1/2 NPT female
2 Amplifier housing: ASTM CF-8M stainless steel
2 Electrical: 1/2 NPT female, two electrical connections, no blind plugs
E Integral indicator: digital indicator with range-setting push button
L Mounting bracket: 316 SST 2-inch pipe mounting bracket

Why the stainless housing changes EJA510E-JDH4N-022EL

Code 2 in the housing position specifies ASTM CF-8M stainless steel instead of the standard cast aluminum alloy. The datasheet notes that this housing adds 1.5 kg to the weight and that it is not available with electrical connection codes 0, 5, 7 or 9 which include blind plugs of other material; EJA510E-JDH4N-022EL uses electrical code 2, so the combination is valid. Epoxy and polyurethane solvent coating is available as option X2 for harsher marine locations, but the stainless housing already reduces corrosion risk. The nameplate and tag are 316 SST in every build.

The stainless housing also changes the vibration clause: the datasheet gives a milder test condition for housing code 2, suitable for field mounting with general or low vibration pipelines, whereas codes 1 and 3 were tested at higher vibration levels. Keep this in mind when the transmitter will be mounted on a skid with reciprocating machinery.

Ratings of the D capsule

Maximum working pressure for the D capsule is 50 MPa abs, which becomes 70 MPa abs if the /HG option is added, and over-pressure is 60 MPa abs (105 MPa with /HG). The datasheet gives a burst pressure of 132 MPa for D capsules. Reference accuracy is plus or minus 0.055 percent of span at spans from 8 MPa up, with an extra term for narrower spans. The ambient temperature effect is expressed against 50 MPa, plus or minus (0.15 percent of span plus 0.15 percent of 50 MPa). At about 1.4 kg, the D-capsule unit is slightly heavier than A, B and C versions, and the stainless housing adds 1.5 kg.

Full specification of EJA510E-JDH4N-022EL

Item Value
Capsule D, 0.5 to 50 MPa abs
Wetted parts Hastelloy C-276 connector, diaphragm and others
Connection 1/2 NPT female (DIN male threads are not offered with D plus H)
Housing ASTM CF-8M stainless steel, plus 1.5 kg
Indicator E, digital with push button
Bracket L, 316 SST 2-inch pipe
Output HART 5/7, 4 to 20 mA
Over-pressure 60 MPa abs
Burst 132 MPa
Stability Plus or minus 0.2 percent URL for 10 years
Response 90 ms

Where Hastelloy and 50 MPa matter

Sour gas wellheads, chemical injection pumps, high-pressure separators and urea or ammonia loops are typical homes for a Hastelloy-wetted high-pressure transmitter. Offshore Gulf platforms favor the stainless housing for its salt-spray resistance. Because Hastelloy C-276 diaphragms and connectors conform to NACE MR0175 and MR0103 according to the datasheet, this variant also fits sour service reviews.

Take S if the process is clean hydrocarbon, water or steam condensate; take H when chlorides, wet hydrogen sulfide, hypochlorite or mild acids are present. The datasheet warns that very aggressive fluids such as hydrochloric acid, sulfuric acid or steam at 150 degrees C and above need confirmation from the manufacturer. Process temperature is limited to 120 degrees C for all codes.

Use the 316 SST bracket with a 2-inch pipe and tighten the process thread with a wrench on the connector. Because of the high pressure, pressure-test the impulse piping before connecting the transmitter and bleed pressure slowly to avoid shocking the diaphragm. Wire through the stainless housing, tighten covers and use the push button to set LRV and URV.

Upkeep

Inspect threads and bracket bolts for corrosion yearly, wash off salt and verify zero at shutdown. Keep a spare unit if the loop is safety related because replacement time for Hastelloy builds can be longer.

Related codes and ordering notes for EJA510E-JDH4N-022EL

If you need the same D capsule with a different wetted parts material, the S code replaces Hastelloy at lower cost and allows DIN male threads; the trade is corrosion resistance. For EJA510E-JDH4N-022EL the bracket is already included and the indicator offers local re-ranging. Compared with the C-capsule siblings in the same series, the pressure window starts at 0.5 MPa rather than 0.1 MPa, so very low spans are not available. Anyone ordering a spare for a high-pressure loop should confirm over-pressure history: the datasheet gives 60 MPa abs for this capsule, which is the ceiling for the unit, not a working value.

Quick answers about EJA510E-JDH4N-022EL

  • Why is Hastelloy selected in EJA510E-JDH4N-022EL? The H code makes the process connector, diaphragm and other wetted parts Hastelloy C-276 for corrosive process fluids.
  • Can DIN G1/2 or M20 threads be used with D and H? No. The datasheet states that codes 8 and 9 are not applicable to the combination of D capsule and H wetted parts, so this model uses 1/2 NPT female.
  • What does the final L mean? L specifies a 316 SST bracket for a 2-inch pipe, delivered with the transmitter.
  • What span does the D capsule cover? 0.5 to 50 MPa absolute, which is 72.5 to 7200 psi.
  • Is this unit SIL certified? In standard HART configuration the EJA-E series is certified SIL 2 capable for single use and SIL 3 for dual use.

Documents and quotation

High-pressure units are worth confirming with a clear tag list, so include the pressure range and fluid in your inquiry.

The manufacturer datasheet GS 01C31F01-01EN for this model family is attached to the product page as a PDF. When you request a quotation, send the full part number EJA510E-JDH4N-022EL, the quantity, the tag or loop number, the process fluid and any approval code you need such as ATEX, IECEx, FM or CSA. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Lead times and availability are confirmed per request.

Other Models in the EJA510E Range

Seven Star LLC supplies models from the EJA510E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa EJA510E-JBS4N-012NN Absolute Pressure TransmitterPressure TransmittersView details
Yokogawa EJA510E-JCS7N-012DN Absolute Pressure with LCDPressure TransmittersView details
Yokogawa EJA510E-JDH4N-022EL Hastelloy Absolute PressurePressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa EJA510E-JDH4N-022EL Hastelloy Absolute Pressure Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJA510E-JDH4N-022EL Hastelloy Absolute

Answers from our engineering team on installation, compatibility and integration.

01Why is Hastelloy selected in EJA510E-JDH4N-022EL?
The H code makes the process connector, diaphragm and other wetted parts Hastelloy C-276 for corrosive process fluids.
02Can DIN G1/2 or M20 threads be used with D and H?
No. The datasheet states that codes 8 and 9 are not applicable to the combination of D capsule and H wetted parts, so this model uses 1/2 NPT female.
03What does the final L mean?
L specifies a 316 SST bracket for a 2-inch pipe, delivered with the transmitter.
04What span does the D capsule cover?
0.5 to 50 MPa absolute, which is 72.5 to 7200 psi.
05Is this unit SIL certified?
In standard HART configuration the EJA-E series is certified SIL 2 capable for single use and SIL 3 for dual use.