Yokogawa EJA118E Diaphragm Sealed DP Transmitter
Description
Yokogawa EJA118E overview: diaphragm sealed differential pressure transmitter with capillaries
The Yokogawa EJA118E is a diaphragm sealed differential pressure transmitter. Diaphragm seals keep the process medium from entering the pressure-sensing assembly directly, and they are connected to the transmitter through capillaries filled with fill fluid, which makes the Yokogawa EJA118E suitable for viscous, corrosive, hot or crystallising media.
Like other EJA-E models, the EJA118E outputs 4 to 20 mA DC proportional to the measured differential pressure, offers BRAIN or HART communication, quick response and self-diagnostics, and can also report static pressure. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 V DC with HART (Low Power) versions are available.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list EJA118E so that maintenance, instrumentation and procurement teams can quote the exact model code that appears in the manufacturer documentation.
Key features of EJA118E
- Diaphragm seal system connected by capillaries to keep aggressive or clogging process fluid away from the sensor.
- Measures liquid, gas or steam flow, liquid level, density and pressure through differential pressure.
- Reference accuracy of plus or minus 0.2 percent of span for spans at or above the stated limit, as specified for capsules M and H in the data sheet.
- Differential pressure update period of 45 ms.
- Ambient temperature limits of -40 to 60 deg C, or -30 to 60 deg C with the LCD display; process temperature limits depend on the seal and fill fluid.
- Standard configuration certified for SIL 2 capability, except for Fieldbus, PROFIBUS PA and low-power types.
EJA118E technical specifications
The table below lists values published by the manufacturer for the product family of EJA118E. Where a value depends on the ordered configuration, the model and suffix code table in the General Specifications governs.
| Parameter | Value |
|---|---|
| Model | EJA118E diaphragm sealed differential pressure transmitter |
| Capsule M span | 2.5 to 100 kPa (range -100 to 100 kPa) |
| Reference accuracy, capsules M and H | Plus or minus 0.2 percent of span for spans at or above the stated limit; formula given for lower spans |
| Output signals | 4 to 20 mA DC with BRAIN or HART; low-power 1 to 5 V HART; FOUNDATION Fieldbus; PROFIBUS PA |
| Differential pressure update period | 45 ms |
| Ambient temperature limits | -40 to 60 deg C; -30 to 60 deg C with LCD display |
| Process temperature limits | Depends on seal type and fill fluid (see manufacturer table) |
| Weight, flush type example | 16.1 kg with 3-inch ANSI Class 150 flange and 5 m capillary |
| Seal connection | Diaphragm seals joined by capillary to the transmitter body |
Typical applications of EJA118E in Oman and the GCC
- Level measurement on closed vessels, columns and reactors with viscous or corrosive fluid.
- Differential pressure across process equipment where the medium could plug impulse lines.
- Hot or crystallising services where a direct impulse line would solidify.
- Sulphur, bitumen, polymer and heavy-oil lines in refining and petrochemical plants.
- Chemical dosing and brine services in water treatment and desalination.
Differential, gauge and absolute pressure transmitters are among the most frequently re-ordered field instruments in Oman and the wider GCC. They sit on orifice runs in gas gathering and export lines, on separators and surge vessels in oil and gas production, on boiler feedwater and steam headers in power and desalination plants, and on filtration and pumping skids in municipal water systems. Summer ambient temperatures, direct sun and salt-laden air make a sealed, corrosion-resistant housing and a stable sensor important, and plant teams like to quote the exact model code from the manufacturer documentation, such as EJA118E, so that a replacement matches the installed base.
Selection and compatibility notes for EJA118E
A EJA118E is a configured system: the seal type, flange size and rating, diaphragm material, capillary length and fill fluid all affect accuracy and temperature performance. The manufacturer table gives the process temperature limits by combination, so state the operating temperature range and pressure when you ask for a quotation.
For level, tell us the vessel height, density of the fluid and whether the vessel is open or closed, because the capillary arrangement and the zero suppression depend on these facts.
Before ordering EJA118E, collect the information that fixes the full model and suffix code: measurement span or capsule, wetted parts material, process connection, output signal, integral indicator, housing and cable-entry type, and any hazardous-area approval your site needs. The manufacturer publishes a model and suffix code table in the General Specifications, and the complete code decides what is actually built, so we compare your request with that table and confirm each option with you before we quote.
Installation and commissioning
Mount the transmitter body at the elevation recommended by your design, keep the two capillaries together and at a similar temperature, and support them so that they cannot be damaged. Avoid sharp bends and do not shorten or cut the capillary, because the filled system is factory assembled.
After installation, adjust zero for the capillary head difference and check the reading at known conditions before the loop goes on line.
Mount the transmitter so that impulse lines or direct connections are short, free of pockets and sloped as the process requires, and use a valve manifold so that the transmitter can be isolated and zeroed in service. Power the loop within the supply and load limits in the data sheet, use screened twisted-pair cable, and keep the housing covers and conduit entries sealed against dust and water. Check the zero with the process isolated and vented, enter the required range and damping, and record the as-left values on the loop sheet.
Maintenance, calibration and service
Inspect the diaphragm seals for build-up or damage at shutdowns, check the capillaries for dents or leaks, and verify the zero at a known level or pressure. A damaged capillary or a lost fill fluid shifts the reading, so replace the complete system rather than repairing it on site.
Smart pressure transmitters need little routine service, but a documented check protects measurement and safety loops. Verify zero and span against a pressure reference at the interval set by your quality or safety system, inspect impulse lines and manifold valves for blockage, leaks or frozen liquid, and look at the cover seals and conduit entries at every visit. Keep a record of the configuration, because a configuration backup makes a like-for-like replacement much faster.
Related products and ordering notes for EJA118E
- EJA110E direct-mount differential pressure transmitters when diaphragm seals are not needed.
- EJX118A, the EJX-series diaphragm sealed differential pressure transmitter.
When you request EJA118E, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. We can also check related codes so that a single RFQ covers the instrument and the parts that go with it.
Frequently asked questions about EJA118E
- What is EJA118E? EJA118E is a diaphragm sealed differential pressure transmitter of the EJA-E series. Diaphragm seals joined by capillaries isolate the sensor from the process medium.
- When should I choose EJA118E instead of a standard DP transmitter? Choose EJA118E when the process fluid is viscous, corrosive, hot or likely to plug impulse lines, because the diaphragm seals protect the sensor and remove the need for wet impulse piping.
- What output does EJA118E provide? It provides 4 to 20 mA DC with BRAIN or HART communication, with Fieldbus, PROFIBUS PA and low-power 1 to 5 V HART versions also available according to the manufacturer.
- What ambient temperature range does EJA118E support? The data sheet lists -40 to 60 deg C, or -30 to 60 deg C when the LCD display is fitted.
- How do I order EJA118E? Send Seven Star LLC the seal type, flange size, capillary length, fill fluid, wetted materials, operating temperature and pressure together with the quantity and delivery location.
Documents and quotation
The manufacturer General Specifications for the family of EJA118E is available and we can send it with your quotation. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number EJA118E, the quantity, the full model and suffix code or the nameplate details of the unit being replaced, the delivery location and any certificate requirements. We will confirm availability and reply in writing with a quotation for EJA118E.
Datasheets & Documents
- Datasheet Yokogawa EJA118E Diaphragm Sealed DP Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa EJA118E Diaphragm Sealed DP Transmitter
Answers from our engineering team on installation, compatibility and integration.
01What is EJA118E?
EJA118E is a diaphragm sealed differential pressure transmitter of the EJA-E series. Diaphragm seals joined by capillaries isolate the sensor from the process medium.
02When should I choose EJA118E instead of a standard DP transmitter?
Choose EJA118E when the process fluid is viscous, corrosive, hot or likely to plug impulse lines, because the diaphragm seals protect the sensor and remove the need for wet impulse piping.
03What output does EJA118E provide?
It provides 4 to 20 mA DC with BRAIN or HART communication, with Fieldbus, PROFIBUS PA and low-power 1 to 5 V HART versions also available according to the manufacturer.
04What ambient temperature range does EJA118E support?
The data sheet lists -40 to 60 deg C, or -30 to 60 deg C when the LCD display is fitted.
05How do I order EJA118E?
Send Seven Star LLC the seal type, flange size, capillary length, fill fluid, wetted materials, operating temperature and pressure together with the quantity and delivery location.