Yokogawa EJX310A Absolute Pressure Transmitter, Traditional Mount: overview

The Yokogawa EJX310A is a high-performance absolute pressure transmitter for liquid, gas and steam pressure. It measures against a sealed vacuum reference and carries the EJX multi-sensing diagnostics, which can flag problems such as a blocked impulse line.

Seven Star LLC lists the Yokogawa EJX310A for engineers, maintenance planners and procurement teams in Oman and across the GCC who need to replace an installed unit, extend a loop or specify a new instrument for an oil and gas, utility, water or manufacturing project. The page below summarizes the key facts from the manufacturer datasheet so that a first technical review can be done before the full document is opened.

Key features of the EJX310A

  • EJX310A uses a single crystal silicon resonant sensor.
  • Stated reference accuracy: l: plus or minus 0.075% of span; m, a, b: plus or minus 0.04% of span (span above the stated limit).
  • Fast response with damping adjustable from 0.00 to 100.00 s, and a 10-segment signal characterizer for the analog output.
  • Integral LCD indicator option with 5-digit display, bar graph and local parameter setting through the external zero adjustment screw.
  • EJX multi-sensing diagnostics detect problems such as impulse line blockage or heat trace breakage, with an optional status output.
  • Cast aluminum housing as standard with IP66/IP67 and Type 4X protection, and stainless steel housing as an option.
  • SIL 2 capability for the standard HART type, so the EJX310A can be used in safety instrumented functions after the usual proof-test planning.

EJX310A technical specifications

Four capsules are offered. The L capsule spans 0.5 to 10 kPa abs, M spans 1.3 to 130 kPa abs, A spans 0.0175 to 3.5 MPa abs and B spans 0.08 to 16 MPa abs. Accuracy is plus or minus 0.075% of span for the L capsule and plus or minus 0.04% of span for the others, and the lower range limit is zero for all capsules.

The stated long-term stability is plus or minus 0.2% of URL per 15 years, with a response time of 90 ms on all capsules.

A maximum over pressure rating of 500 kPa abs applies to the L and M capsules, so test and start-up pressures must be controlled on low-range versions.

The table lists the main values stated in the datasheet for this model. Values depend on the selected capsule, wetted material and options, so always confirm the final model code with the datasheet before ordering.

Parameter Value
Type Absolute pressure transmitter, traditional (cover flange) mount
Capsule L span 0.5 to 10 kPa abs (0.15 to 2.95 inHg abs)
Capsule M span 1.3 to 130 kPa abs (0.39 to 38 inHg abs)
Capsule A span 0.0175 to 3.5 MPa abs (2.5 to 500 psi abs)
Capsule B span 0.08 to 16 MPa abs (12 to 2300 psi abs)
Reference accuracy L: plus or minus 0.075% of span; M, A, B: plus or minus 0.04% of span (span above the stated limit)
Maximum over pressure L and M: 500 kPa abs; A: 16 MPa abs; B: 25 MPa abs
Stability Plus or minus 0.2% of URL per 15 years
Ambient temperature -40 to 85 C (-30 to 80 C with LCD display)
Process temperature -40 to 120 C for M, A, B; -40 to 100 C for L
Response time 90 ms, all capsules
Output 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered
Diagnostics Multi-sensing diagnostics; optional status output for pressure high and low alarm
Weight 2.8 kg without indicator, bracket and process connector

Typical applications in Oman and the GCC

  • Oil and gas. Upstream and midstream facilities use the EJX310A for condenser vacuum, deaerator and evaporator pressure, flare and vent headers, vacuum drying and gas compressor suction, where a stable digital signal and fast response help the control system and the safety layer.
  • Utilities and power. In power and utility plants across the GCC the EJX310A supports steam, feedwater, fuel gas and cooling circuits, and its diagnostics reduce unplanned inspection walks in hot plant areas.
  • Water and desalination. Desalination and water treatment plants rely on pressure and differential pressure points for pump protection and membrane skid monitoring, and a EJX310A fits those duties with materials chosen for the water chemistry.
  • Manufacturing and process. Petrochemical, fertilizer, food and general manufacturing units in Oman use the EJX310A on reactors, filters, compressors and storage, where HART or fieldbus communication feeds asset-management software.

Selection and compatibility notes

Start the selection of a EJX310A from the measured variable and the calibrated span, then pick the capsule whose upper range limit leaves comfortable margin. The datasheet shows that accuracy is quoted for spans at or above a capsule-specific value and carries an extra term for narrower spans, so very high rangedown should be checked against the formula rather than assumed.

Check the wetted materials against the process and the cleaning or flushing chemicals. Material code S with a Hastelloy C-276 diaphragm is the typical starting point, and other materials can be selected through the model code. The datasheet warns that an unsuitable material can leak process fluid or damage the diaphragm, so the choice must be made with the process conditions in hand.

Output and protocol should follow the control system. A 4 to 20 mA signal with digital communication is standard, and Fieldbus and PROFIBUS PA types have separate datasheets. For hazardous areas, review the approval options listed in the datasheet, such as FM, ATEX, CSA and IECEx, and confirm that the certificate on the nameplate matches the zone and gas group of the installation.

Installation and commissioning of the EJX310A

Mount the EJX310A close to the tapping point and keep the impulse line short and free of traps. For liquid service on a level duty, the zero must be set with the actual head of liquid in mind. Install an isolation and vent valve at the process connection so the transmitter can be removed or calibrated without shutting down the process.

After mounting, apply the electrical connection through the conduit entry, ground the housing, and power the loop. Perform a loop test and set the zero with the process isolated or the impulse lines equalized. Range the EJX310A either with a HART or BRAIN communicator or locally through the zero adjustment screw. Document the tag, range and damping in the commissioning record.

Maintenance and calibration

The EJX310A needs little routine maintenance. Check zero and span against a reference standard at an interval set by your calibration policy, inspect impulse lines and vent or drain plugs for blockage and leakage, and review the diagnostics reported by the transmitter. Keep the housing covers tight with intact O-rings, because the enclosure rating depends on them. Spare indicator and amplifier units can be changed in the field without touching the process.

Related products and ordering notes for the EJX310A

Other Yokogawa models in the same product area include EJX510A, EJX610A, EJX110A and EJA310E, which may suit neighboring points on the same plant. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model codes are used only to identify compatible equipment.

When you ask for a quotation, state the exact model code, the measuring range, the output type, any hazardous area approval and the quantity. A complete code lets us confirm that the unit matches the installed unit or the project specification, and it avoids delays caused by option mismatches.

Frequently asked questions in short

What is the Yokogawa this model? The Yokogawa this model is a high-performance absolute pressure transmitter. The this model is a high-performance absolute pressure transmitter for liquid, gas and steam pressure. What measuring ranges does the this model cover? Datasheet values for the EJX310A: 0.5 to 10 kPa abs (0.15 to 2.95 inHg abs); 1.3 to 130 kPa abs (0.39 to 38 inHg abs); 0.0175 to 3.5 MPa abs (2.5 to 500 psi abs); 0.08 to 16 MPa abs (12 to 2300 psi abs). What accuracy and output does the EJX310A provide? For the EJX310A the datasheet gives l: plus or minus 0.075% of span; m, a, b: plus or minus 0.04% of span (span above the stated limit). Output and communication: 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered.

Documents and quotation

The manufacturer datasheet for the EJX310A is attached to this page and gives the complete model and suffix codes, dimensions and options. To receive a quotation, send the RFQ with the part number EJX310A, the quantity and your required range and approvals, and the Seven Star LLC team will reply with availability and delivery information for Oman and the GCC.

Other Models in the Yokogawa Abs Range

Seven Star LLC supplies models from the Yokogawa Abs range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa EJA310E Absolute Pressure Transmitter, Traditional MountPressure TransmittersView details
Yokogawa EJX310A Absolute Pressure Transmitter, Traditional MountPressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa EJX310A Absolute Pressure Transmitter, Traditional Mount Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJX310A Absolute Pressure Transmitter,

Answers from our engineering team on installation, compatibility and integration.

01What is the Yokogawa EJX310A?
The Yokogawa EJX310A is a high-performance absolute pressure transmitter. The EJX310A is a high-performance absolute pressure transmitter for liquid, gas and steam pressure.
02What measuring ranges does the EJX310A cover?
Datasheet values for the EJX310A: 0.5 to 10 kPa abs (0.15 to 2.95 inHg abs); 1.3 to 130 kPa abs (0.39 to 38 inHg abs); 0.0175 to 3.5 MPa abs (2.5 to 500 psi abs); 0.08 to 16 MPa abs (12 to 2300 psi abs).
03What accuracy and output does the EJX310A provide?
For the EJX310A the datasheet gives l: plus or minus 0.075% of span; m, a, b: plus or minus 0.04% of span (span above the stated limit). Output and communication: 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered.
04How is the EJX310A installed on a process line?
The EJX310A is installed near the tapping point with a short impulse line or process connector, an isolation valve and a vent valve, so that it can be zeroed and removed without stopping the process.
05How can I request a quotation for the EJX310A in Oman?
Send an RFQ with the part number EJX310A, quantity, range, output and approvals through the inquiry form. Seven Star LLC replies with availability and delivery for Oman and the GCC, and the datasheet is on the product page.