Yokogawa EJA115E-JFS4G-712EK-N00NN0 F Capsule Low Flow
Description
Smallest flows, smallest span: EJA115E-JFS4G-712EK-N00NN0
The F capsule is the most sensitive element of the EJA115E family. Yokogawa EJA115E-JFS4G-712EK-N00NN0 uses it to measure differential pressures from 1 to 5 kPa, which, with the integral orifice, corresponds to water flows from 0.016 l/min and air flows from 0.44 Nl/min depending on bore. The code adds 316L stainless bolting, a vertical piping arrangement with left-side high pressure and manifold downside, a digital indicator with push button and a 316 SST L-type bracket.
EJA115E-JFS4G-712EK-N00NN0 suffix, position by position
| Code position | Meaning |
|---|---|
| -J | 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering) |
| F | Capsule: span 1 to 5 kPa |
| S | Wetted parts: cover flange and process connector ASTM CF-8M, Hastelloy C-276 diaphragm, 316L SST others, PTFE orifice gasket |
| 4 | Process connection: 1/2 NPT female |
| G | Bolts and nuts: 316L SST throughout |
| -7 | Installation: vertical piping, left side high pressure, manifold downside |
| 1 | Amplifier housing: cast aluminum alloy |
| 2 | Electrical: 1/2 NPT female, two electrical connections, no blind plugs |
| E | Integral indicator: digital indicator with range-setting push button |
| K | Mounting bracket: 316 SST 2-inch pipe bracket, L type (vertical piping) |
| -N00NN0 | Fixed trailing code, always the same for this model |
F capsule specifics
At the F capsule, reference accuracy is plus or minus 0.055 percent of span for spans of 2 kPa or larger; below 2 kPa the datasheet gives the term 0.005 plus 0.02 times URL over span. URL is 5 kPa. Ambient temperature effect is plus or minus (0.08 percent span plus 0.18 percent URL) per 28 degrees C, notably larger than for M and H capsules, and the static-pressure effect on zero is plus or minus (0.04 percent of span plus 0.208 percent of URL) per 6.9 MPa. Response time is 150 ms against 90 ms for M and H. Weight is 5.4 kg for installation codes 7, 8 and 9.
Data table for EJA115E-JFS4G-712EK-N00NN0
| Item | Value |
|---|---|
| Capsule F | 1 to 5 kPa (100 to 500 mmH2O) |
| Water-equivalent flow | 0.016 to 0.035 l/min (0.508 mm bore) up to 2.3 to 5.0 l/min (6.350 mm bore) |
| Air-equivalent flow | 0.44 to 0.981 Nl/min up to 63 to 140 Nl/min |
| Bolts | 316L SST for cover flange, connector and manifold |
| Installation -7 | Vertical piping, left high pressure, manifold downside |
| Indicator | E, digital with range-setting switch |
| Bracket | K, 316 SST L type |
| Max working pressure | 16 MPa |
| Response | 150 ms |
| Weight | 5.4 kg without indicator and bracket |
Where an F capsule pays off
Very small gas flows, trace chemical injection, purge flows on analyzers and instrument purge rotameter replacement are natural fits. The long-term stability of the F capsule is not listed separately, whereas M and H capsules are quoted at plus or minus 0.1 percent of URL per 10 years. For that reason, plan zero checks at each shutdown.
Why 316L bolts
Bolt code G gives 316L stainless bolts and nuts on cover flange, process connector and manifold. This avoids carbon steel corrosion in marine or washdown environments and suits fluids that attack zinc-plated hardware. The datasheet notes two bolt options, J and G, for this model.
Installing EJA115E-JFS4G-712EK-N00NN0
Because the installation code is -7, the manifold sits below and the high-pressure side is on the left in vertical piping. Mount with the L-type bracket on a vertical 2-inch pipe. Pay attention to orientation: wrong flow direction gives a negative signal. Use the push button for range setting, and let the indicator rotate through the variables you need, since the EJA115E can show differential pressure and static pressure on the same display.
Keep the manifold plugs tight and check for leaks with a soap solution. Zero trim after final mounting.
Ordering notes for EJA115E-JFS4G-712EK-N00NN0
The suffix of EJA115E-JFS4G-712EK-N00NN0 combines choices that are easy to confuse with the very similar M-capsule part numbers, so check three things before ordering: the capsule letter, the bolting letter and the installation digit. A different installation digit changes which side is high pressure and whether the manifold is up or down, so a unit ordered with the wrong digit will need its flow direction reversed in the field. The datasheet also lists slash options such as fluoro-rubber gaskets N2 and N3, oil-free cleaning K1 and K2, and approval codes, all of which change the order.
The orifice itself is specified by bore, and the bore is fixed once the unit is built, so provide the flow data at the time of the RFQ.
Quick answers about EJA115E-JFS4G-712EK-N00NN0
- What is special about the F capsule? It spans 1 to 5 kPa, the lowest range in the EJA115E family, for the smallest flows.
- Why does EJA115E-JFS4G-712EK-N00NN0 have a slower response? The F capsule has a response time of 150 ms against 90 ms for M and H capsules.
- What does installation code 7 mean? Vertical piping, left side high pressure, manifold downside.
- Does the part include a bracket? Yes. K is a 316 SST two-inch pipe bracket, L type, for vertical piping.
- What is the bolting material? 316L stainless steel, code G, for the cover flange, process connector and manifold.
Documents and quotation
Share your flow range and fluid so that the orifice bore can be matched.
Yokogawa general specification GS 01C31K01-01EN for the EJA115E low flow transmitter is supplied as the datasheet PDF with this listing. Send the full part number EJA115E-JFS4G-712EK-N00NN0, the quantity, the tag numbers and, because an integral orifice is calibrated to the flow case, the flow data or orifice bore you need. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Availability and lead time are confirmed per RFQ.
Other Models in the EJA115E Range
Seven Star LLC supplies models from the EJA115E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Yokogawa EJA115E-JMS4J-912NB-N00NN0 Low Flow Transmitter | Pressure Transmitters | View details |
| Yokogawa EJA115E-JFS4G-712EK-N00NN0 F Capsule Low Flow | Pressure Transmitters | You are viewing this model |
| Yokogawa EJA115E-DHS2J-312DD-N00NN0 Low Flow BRAIN | Pressure Transmitters | View details |
Datasheets & Documents
- Datasheet Yokogawa EJA115E-JFS4G-712EK-N00NN0 F Capsule Low Flow Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa EJA115E-JFS4G-712EK-N00NN0 F Capsule Low
Answers from our engineering team on installation, compatibility and integration.
01What is special about the F capsule?
It spans 1 to 5 kPa, the lowest range in the EJA115E family, for the smallest flows.
02Why does EJA115E-JFS4G-712EK-N00NN0 have a slower response?
The F capsule has a response time of 150 ms against 90 ms for M and H capsules.
03What does installation code 7 mean?
Vertical piping, left side high pressure, manifold downside.
04Does the part include a bracket?
Yes. K is a 316 SST two-inch pipe bracket, L type, for vertical piping.
05What is the bolting material?
316L stainless steel, code G, for the cover flange, process connector and manifold.