Brand: Yokogawa
Yokogawa EJX510A-JDS9N-022EN Absolute Pressure 50 MPa
Description
50 MPa absolute: the case for EJX510A-JDS9N-022EN
High pressure measurement is demanding enough; high pressure measured against vacuum is rarer still. Yokogawa EJX510A-JDS9N-022EN puts the D capsule, 0.5 to 50 MPa absolute, into an EJX510A with HART 5/7 output, an M20 x 1.5 DIN male process thread, an ASTM CF-8M stainless housing with 1/2 NPT conduit entries, and a digital indicator with range-setting push button. There is no bracket.
The suffix of EJX510A-JDS9N-022EN explained
| Code position | Meaning |
|---|---|
| -J | 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering) |
| D | Capsule: span 0.5 to 50 MPa |
| S | 316L SST process connector, Hastelloy C-276 diaphragm, 316L SST or F316L SST other wetted parts |
| 9 | Process connection: M20 x 1.5 DIN 16 288 male |
| 2 | Amplifier housing: ASTM CF-8M stainless steel |
| 2 | Electrical: 1/2 NPT female, two electrical connections, no blind plugs |
| E | Integral indicator: digital indicator with range-setting push button |
| N | Mounting bracket: none |
Over-pressure and burst on D capsule
For the EJX510A the D capsule can withstand 75 MPa abs over-pressure, higher than the 60 MPa given for the EJA510E. Maximum working pressure is 50 MPa abs and burst pressure is 132 MPa. Reference accuracy is plus or minus 0.04 percent of span for spans of 5 MPa and above; below that the datasheet formula uses 0.004 times URL over span. The ambient effect is expressed as plus or minus (0.15 percent span plus 0.15 percent URL) per 28 degrees C. The D capsule unit weighs 1.4 kg, and the stainless housing adds 1.5 kg.
Coastal and offshore reasons for housing code 2
An ASTM CF-8M stainless steel housing resists salt-laden air, so this specification suits coastal refineries and offshore platforms around the Arabian Sea and the Gulf. It adds 1.5 kg to the transmitter weight and comes with a vibration test condition described for general field or low-vibration pipelines, not the heavy-vibration level tested on housing codes 1 and 3. If the transmitter will be bolted to a compressor skid, ask for a bracket and a flexible impulse connection or use a remote location. The datasheet also lists an anti-corrosion coating option (/X2) for the aluminum housings, an option you would not need with stainless steel.
Specifications of EJX510A-JDS9N-022EN
| Item | Value |
|---|---|
| Capsule D | 0.5 to 50 MPa abs span; URL 50 MPa abs |
| Over-pressure | 75 MPa abs |
| Burst | 132 MPa |
| Stability | Plus or minus 0.2 percent URL, 15 years |
| Process connection | M20 x 1.5 DIN 16 288 male |
| Wetted parts | 316L SST connector, Hastelloy C-276 diaphragm |
| Housing | ASTM CF-8M stainless steel |
| Indicator | Digital with range-setting push button |
| Response | 90 ms |
| Output | 4 to 20 mA, HART 5/7 |
Sites and services
High-pressure absolute service includes injection water, gas lift, hydraulic testing rigs and other high-pressure process skids. The metric M20 thread suits equipment built to European standards. The stainless housing fits corrosive coastal installations on the Gulf and Arabian Sea.
Thread caution
Per the datasheet, DIN male threads (codes 8 and 9) cannot be combined with the D capsule and H wetted parts, so S material is used here; the thread is based on withdrawn DIN 16 288. A matching female fitting or sealing washer is required and it should be rated to 50 MPa.
Pressurize slowly, check for leaks with a safe medium, set LRV and URV with the push button. The housing and cover need two hands on the cover thread and care with the O-ring.
Maintenance
Record zero at each shutdown and compare it with the last value for trend. A drift larger than the stability specification suggests a service call. Inspect the O-rings of both covers when the unit is opened, keep the M20 male thread free of corrosion, and confirm the integral indicator units still match the loop sheet after any reconfiguration.
For lower pressure windows in the same family, the A, B and C capsules drop the maximum working pressure to 200 kPa, 2 MPa and 10 MPa abs. For EJX510A-JDS9N-022EN, the bracket position is N, so a separate bracket has to be arranged. If the pressure transmitter is also required for hazardous areas, the datasheet lists flameproof and intrinsically safe options under slash codes; the stainless housing code 2 can be used with electrical connection codes 2, 4, A, C and D, but not 0, 5, 7 or 9. Because the diaphragm is already Hastelloy C-276 in the S code, the all-Hastelloy H code adds the connector and other wetted parts; note that H cannot be combined with DIN male threads when the D capsule is chosen.
Quick answers about EJX510A-JDS9N-022EN
- What is the maximum pressure of EJX510A-JDS9N-022EN? Maximum working pressure for the D capsule is 50 MPa abs, with 75 MPa abs over-pressure and 132 MPa burst.
- Can this model use Hastelloy wetted parts? Not as this part number: S selects 316L and a Hastelloy diaphragm. H is the code for all-Hastelloy.
- What does 2 as the housing code mean? ASTM CF-8M stainless steel housing, which adds 1.5 kg.
- Is there local range setting? Yes. E indicator includes the push button.
- What is the process thread? It is an M20 x 1.5 DIN 16 288 male thread, selected by code 9 in the process connection position.
Documents and quotation
Because of the pressure level, include the working pressure and test pressure in your RFQ.
The Yokogawa general specification GS 01C25F01-01EN, which covers the EJX510A and EJX530A, is supplied as the datasheet PDF with this listing. To request a quotation, send the part number EJX510A-JDS9N-022EN, the quantity, tag numbers, process fluid and the approval you need if the area is classified. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Availability and lead time are confirmed per RFQ.
Other Models in the EJX510A Range
Seven Star LLC supplies models from the EJX510A range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Yokogawa EJX510A-JCS4N-012DN Absolute Pressure Transmitter | Pressure Transmitters | View details |
| Yokogawa EJX510A-EAS7N-012NL Absolute, 8 to 200 kPa | Pressure Transmitters | View details |
| Yokogawa EJX510A-JDS9N-022EN Absolute Pressure 50 MPa | Pressure Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Yokogawa EJX510A-JDS9N-022EN Absolute Pressure 50 MPa Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa EJX510A-JDS9N-022EN Absolute Pressure 50
Answers from our engineering team on installation, compatibility and integration.
01What is the maximum pressure of EJX510A-JDS9N-022EN?
Maximum working pressure for the D capsule is 50 MPa abs, with 75 MPa abs over-pressure and 132 MPa burst.
02Can this model use Hastelloy wetted parts?
Not as this part number: S selects 316L and a Hastelloy diaphragm. H is the code for all-Hastelloy.
03What does 2 as the housing code mean?
ASTM CF-8M stainless steel housing, which adds 1.5 kg.
04Is there local range setting?
Yes. E indicator includes the push button.
05What is the process thread?
It is an M20 x 1.5 DIN 16 288 male thread, selected by code 9 in the process connection position.


















Reviews