Brand:

Yokogawa EJX115A Low Flow Transmitter with Integral Orifice

Description

Yokogawa EJX115A Low Flow Transmitter with Integral Orifice: overview

The Yokogawa EJX115A is the EJX-A generation low-flow transmitter. A differential pressure sensor and an integral orifice are combined in one body for very low liquid, gas and steam flows, and the EJX multi-sensing technology adds diagnostics that older designs lack.

Seven Star LLC lists the Yokogawa EJX115A for engineers, maintenance planners and procurement teams in Oman and across the GCC who need to replace an installed unit, extend a loop or specify a new instrument for an oil and gas, utility, water or manufacturing project. The page below summarizes the key facts from the manufacturer datasheet so that a first technical review can be done before the full document is opened.

Key features of the EJX115A

  • EJX115A pairs a stable pressure sensor with an integral orifice for very low flows.
  • Stated reference accuracy: plus or minus 0.04% of span for all capsules when the span is at or above the stated limit.
  • Fast response with damping adjustable from 0.00 to 100.00 s, and a 10-segment signal characterizer for the analog output.
  • Integral LCD indicator option with 5-digit display, bar graph and local parameter setting through the external zero adjustment screw.
  • EJX multi-sensing diagnostics detect problems such as impulse line blockage or heat trace breakage, with an optional status output.
  • Cast aluminum housing as standard with IP66/IP67 and Type 4X protection, and stainless steel housing as an option.
  • SIL 2 capability for the standard HART type, so the EJX115A can be used in safety instrumented functions after the usual proof-test planning.

EJX115A technical specifications

Three capsules match the EJA115E ranges: F for 1 to 5 kPa, M for 2 to 100 kPa and H for 20 to 210 kPa, with water-equivalent and air-equivalent flow ranges given for each in the datasheet. The reference accuracy of plus or minus 0.04% of span applies to the differential pressure transmitter portion, while the integral orifice itself is quoted at plus or minus 5% of span.

The EJX multi-sensing technology provides advanced diagnostics to detect abnormalities such as an impulse line blockage or heat trace breakage, and an optional status output can signal pressure high or low alarms to a PLC.

All EJX series models in their standard configuration, except the Fieldbus and PROFIBUS types, are certified as complying with SIL 2 for safety requirements.

The table lists the main values stated in the datasheet for this model. Values depend on the selected capsule, wetted material and options, so always confirm the final model code with the datasheet before ordering.

Parameter Value
Type Differential pressure transmitter with integral orifice for very low flow
Capsule F span 1 to 5 kPa (100 to 500 mmH2O); water equivalent 0.016 to 5.0 l/min; air 0.44 to 140 Nl/min
Capsule M span 2 to 100 kPa (200 to 10000 mmH2O); water 0.022 to 23.0 l/min; air 0.63 to 635 Nl/min
Capsule H span 20 to 210 kPa (2000 to 21000 mmH2O); water 0.07 to 33.0 l/min; air 2.0 to 910 Nl/min
Integral orifice accuracy Plus or minus 5% of span
Reference accuracy (differential pressure) Plus or minus 0.04% of span for all capsules when the span is at or above the stated limit
Maximum working pressure 16 MPa (2300 psi), all capsules
Ambient temperature -40 to 85 C (-30 to 80 C with LCD display)
Process temperature -40 to 120 C
Response time 90 ms for M and H capsules, 150 ms for F capsule
Output 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered
Diagnostics Multi-sensing diagnostics including impulse line blockage and heat trace breakage detection; optional status output
Wetted parts, code S Cover flange and process connector ASTM CF-8M, Hastelloy C-276 diaphragm, 316 SST orifice
Weight 4.5 kg for M and H capsules, 5.4 kg for F capsule (without indicator, bracket and process connector)

Typical applications in Oman and the GCC

  • Oil and gas. Upstream and midstream facilities use the EJX115A for chemical dosing lines, hydrogen and nitrogen blanketing, seal-flush and lube-oil flow, sample systems and pilot or test plant flow loops, where a stable digital signal and fast response help the control system and the safety layer.
  • Utilities and power. In power and utility plants across the GCC the EJX115A supports steam, feedwater, fuel gas and cooling circuits, and its diagnostics reduce unplanned inspection walks in hot plant areas.
  • Water and desalination. Desalination and water treatment plants rely on pressure and differential pressure points for pump protection and membrane skid monitoring, and a EJX115A fits those duties with materials chosen for the water chemistry.
  • Manufacturing and process. Petrochemical, fertilizer, food and general manufacturing units in Oman use the EJX115A on reactors, filters, compressors and storage, where HART or fieldbus communication feeds asset-management software.

Selection and compatibility notes

Start the selection of a EJX115A from the measured variable and the calibrated span, then pick the capsule whose upper range limit leaves comfortable margin. The datasheet shows that accuracy is quoted for spans at or above a capsule-specific value and carries an extra term for narrower spans, so very high rangedown should be checked against the formula rather than assumed.

Check the wetted materials against the process and the cleaning or flushing chemicals. Material code S with a Hastelloy C-276 diaphragm is the typical starting point, and other materials can be selected through the model code. The datasheet warns that an unsuitable material can leak process fluid or damage the diaphragm, so the choice must be made with the process conditions in hand.

Output and protocol should follow the control system. A 4 to 20 mA signal with digital communication is standard, and Fieldbus and PROFIBUS PA types have separate datasheets. For hazardous areas, review the approval options listed in the datasheet, such as FM, ATEX, CSA and IECEx, and confirm that the certificate on the nameplate matches the zone and gas group of the installation.

Installation and commissioning of the EJX115A

Mount the EJX115A on a rigid bracket or directly on a manifold, with the process connections oriented to suit the impulse line slope. Use a three-valve or five-valve manifold so that the transmitter can be isolated, equalized and zeroed without breaking process connections. For gas service, mount above the tapping points; for liquids, mount below, and keep both impulse lines at the same temperature to avoid false differential readings.

After mounting, apply the electrical connection through the conduit entry, ground the housing, and power the loop. Perform a loop test and set the zero with the process isolated or the impulse lines equalized. Range the EJX115A either with a HART or BRAIN communicator or locally through the zero adjustment screw. Document the tag, range and damping in the commissioning record.

Maintenance and calibration

The EJX115A needs little routine maintenance. Check zero and span against a reference standard at an interval set by your calibration policy, inspect impulse lines and vent or drain plugs for blockage and leakage, and review the diagnostics reported by the transmitter. Keep the housing covers tight with intact O-rings, because the enclosure rating depends on them. Spare indicator and amplifier units can be changed in the field without touching the process.

Related products and ordering notes for the EJX115A

Other Yokogawa models in the same product area include EJX110A, EJX120A, EJX130A and EJA115E, which may suit neighboring points on the same plant. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model codes are used only to identify compatible equipment.

When you ask for a quotation, state the exact model code, the measuring range, the output type, any hazardous area approval and the quantity. A complete code lets us confirm that the unit matches the installed unit or the project specification, and it avoids delays caused by option mismatches.

Frequently asked questions in short

What is the Yokogawa this model? The Yokogawa this model is a low-flow differential pressure transmitter with an integral orifice. The this model is the EJX-A generation low-flow transmitter. What measuring ranges does the this model cover? Datasheet values for the EJX115A: 1 to 5 kPa (100 to 500 mmH2O); water equivalent 0.016 to 5.0 l/min; air 0.44 to 140 Nl/min; 2 to 100 kPa (200 to 10000 mmH2O); water 0.022 to 23.0 l/min; air 0.63 to 635 Nl/min; 20 to 210 kPa (2000 to 21000 mmH2O); water 0.07 to 33.0 l/min; air 2.0 to 910 Nl/min. What accuracy and output does the EJX115A provide? For the EJX115A the datasheet gives plus or minus 0.04% of span for all capsules when the span is at or above the stated limit. Output and communication: 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered.

Documents and quotation

The manufacturer datasheet for the EJX115A is attached to this page and gives the complete model and suffix codes, dimensions and options. To receive a quotation, send the RFQ with the part number EJX115A, the quantity and your required range and approvals, and the Seven Star LLC team will reply with availability and delivery information for Oman and the GCC.

Other Models in the Yokogawa Lowflow Range

Seven Star LLC supplies models from the Yokogawa Lowflow range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa EJA115E Low Flow Transmitter with Integral OrificePressure TransmittersView details
Yokogawa EJX115A Low Flow Transmitter with Integral OrificePressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa EJX115A Low Flow Transmitter with Integral Orifice Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJX115A Low Flow Transmitter with Integral

Answers from our engineering team on installation, compatibility and integration.

01What is the Yokogawa EJX115A?
The Yokogawa EJX115A is a low-flow differential pressure transmitter with an integral orifice. The EJX115A is the EJX-A generation low-flow transmitter.
02What measuring ranges does the EJX115A cover?
Datasheet values for the EJX115A: 1 to 5 kPa (100 to 500 mmH2O); water equivalent 0.016 to 5.0 l/min; air 0.44 to 140 Nl/min; 2 to 100 kPa (200 to 10000 mmH2O); water 0.022 to 23.0 l/min; air 0.63 to 635 Nl/min; 20 to 210 kPa (2000 to 21000 mmH2O); water 0.07 to 33.0 l/min; air 2.0 to 910 Nl/min.
03What accuracy and output does the EJX115A provide?
For the EJX115A the datasheet gives plus or minus 0.04% of span for all capsules when the span is at or above the stated limit. Output and communication: 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered.
04Which accessories are normally used with the EJX115A?
The EJX115A is normally installed with a three-valve or five-valve manifold, impulse piping and a mounting bracket, plus a HART communicator or configuration software for ranging and diagnostics.
05How can I request a quotation for the EJX115A in Oman?
Send an RFQ with the part number EJX115A, quantity, range, output and approvals through the inquiry form. Seven Star LLC replies with availability and delivery for Oman and the GCC, and the datasheet is on the product page.