Brand:

Yokogawa EJA120E-JES5J-912NB Draft Range DP Transmitter

Description

Measuring a fraction of a kilopascal: EJA120E-JES5J-912NB

A furnace draft of minus 50 pascals or a clean-room pressure cascade of 10 pascals is far below what ordinary pressure transmitters can resolve. Yokogawa EJA120E-JES5J-912NB is the EJA120E draft range differential pressure transmitter, built around the E capsule which accepts spans between 0.1 and 1 kPa (0.4 to 4 inH2O). The measurement range itself runs from minus 1 to 1 kPa, so positive, negative and bidirectional draft readings are all possible.

This particular code is the base configuration: HART output, no process connectors with 1/4 NPT female threads on the cover flanges, B7 carbon steel bolting, horizontal piping with left-side high pressure, aluminum housing, two 1/2 NPT conduit entries, no indicator and a flat 304 SST bracket.

EJA120E-JES5J-912NB suffix guide

Code position Meaning
-J 4 to 20 mA DC with HART 5 or HART 7 digital communication (selected at ordering)
E Capsule: 0.1 to 1 kPa span (0.4 to 4 inH2O)
S Wetted parts: ASTM CF-8M cover flange and connector, Hastelloy C-276 diaphragm, PTFE gasket, 316 SST vent/drain plug
5 Process connection: no process connector (1/4 NPT female on the cover flanges)
J Bolts and nuts: B7 carbon steel
-9 Installation: horizontal piping, left side high pressure
1 Amplifier housing: cast aluminum alloy
2 Electrical: 1/2 NPT female, two electrical connections, no blind plugs
N Integral indicator: none
B Mounting bracket: 304 SST 2-inch pipe bracket, flat type (horizontal piping)

What the E capsule can and cannot do

Reference accuracy is plus or minus 0.2 percent of span for spans of 0.4 kPa or larger; for smaller spans the datasheet adds a term of 0.15 plus 0.02 times URL over span. Option /HAC reduces this to plus or minus 0.09 percent. Ambient temperature effect is plus or minus (0.15 percent span plus 0.2 percent URL) per 28 degrees C and long-term stability is plus or minus 0.3 percent of URL per year, a shorter period than the ten-year figure for the high-pressure EJA-E models. Response time is 150 ms. Working pressure is limited to minus 50 to 50 kPa, and process and ambient temperature to minus 25 to 80 degrees C.

Specification sheet of EJA120E-JES5J-912NB

Item Value
Capsule E Span 0.1 to 1 kPa (0.4 to 4 inH2O); range minus 1 to 1 kPa
Accuracy Plus or minus 0.2 percent of span, span 0.4 kPa or more
Stability Plus or minus 0.3 percent URL per year
Working pressure Minus 50 to 50 kPa
Process and ambient temperature Minus 25 to 80 degrees C
Output 4 to 20 mA, HART 5/7
Response 150 ms
Update period 45 ms
Process connection 1/4 NPT female on the cover flanges
Bolting B7 carbon steel
Weight 3.7 kg without indicator and bracket
Zero shift on 90 degree tilt Up to 0.4 kPa, correctable by zero adjustment

Applications

Boiler furnace draft, flue gas stack draft, combustion-air duct pressure, HVAC filter resistance, clean room and hospital pressure cascades, and ventilation of motor control rooms or analyzer shelters. In the Gulf, positive-pressure purge of analyzer houses and switchgear rooms is a frequent use, where a few tens of pascals prove the purge is on.

Mounting angle matters

The datasheet warns that tilting by 90 degrees causes a zero shift of up to 0.4 kPa. On a span of 0.1 to 1 kPa that is a large fraction of range, so a field zero trim after installation is mandatory, and the transmitter should not be rotated afterward. Mount it at its final angle, then trim.

Connecting and wiring

Because no process connector is fitted, impulse lines connect directly to the 1/4 NPT female threads on the cover flanges. Keep the impulse tubing short, equal in length and free of liquid traps. Horizontal piping code -9 puts the high-pressure side on the left. For draft service, vent the low side to the atmosphere via a short tube protected against dust.

Service tips

Check impulse lines for blockage with dust or condensate and flush them periodically. Trim zero with both sides connected together.

Electrical data and options for EJA120E-JES5J-912NB

The loop is a conventional two-wire 4 to 20 mA circuit with HART superimposed. Supply voltage is 10.5 to 42 V DC for general use, 10.5 to 30 V DC for intrinsically safe types and 10.5 to 32 V DC with the lightning protector /A. HART needs at least 16.6 V at the terminals and 250 to 600 ohm of loop resistance. The output range is 3.6 to 21.6 mA and the failure alarm goes up-scale to 110 percent by default; options C1, C2 and C3 select down-scale or NAMUR NE43 limits. The standard configuration is certified SIL 2 capable for single use and SIL 3 for dual use under IEC 61508. Slash options listed in the datasheet include /HAC, /X2 anti-corrosion coating and /HE fluoro-rubber O-rings (which raise the lower ambient limit to minus 15 degrees C), and each creates a different quotation from EJA120E-JES5J-912NB.

Quick answers about EJA120E-JES5J-912NB

  • What range does EJA120E-JES5J-912NB cover? Spans of 0.1 to 1 kPa, with a range from minus 1 to 1 kPa.
  • Is a process connector fitted? No. Code 5 means the 1/4 NPT female threads on the cover flanges are used directly.
  • How accurate is it? Plus or minus 0.2 percent of span for spans of 0.4 kPa or larger, or plus or minus 0.09 percent with option HAC.
  • Why must zero be trimmed after mounting? Because a 90 degree tilt shifts zero by up to 0.4 kPa, large relative to the span of 0.1 to 1 kPa.
  • Which bracket is supplied? B is a 304 SST two-inch flat pipe bracket for horizontal piping.

Documents and quotation

Please describe the draft range and mounting orientation.

The datasheet for this model, Yokogawa GS 01C31B03-01EN, is attached as a PDF to the listing. In the RFQ please give the full part number EJA120E-JES5J-912NB, quantity, tag numbers and the draft or low differential pressure you need to measure. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Stock status and lead time are confirmed per request.

Other Models in the EJA120E Range

Seven Star LLC supplies models from the EJA120E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa EJA120E-JES5J-912NB Draft Range DP TransmitterPressure TransmittersYou are viewing this model
Yokogawa EJA120E-DES4G-812DJ Draft Range DP, BRAINPressure TransmittersView details
Yokogawa EJA120E-JES1C-U22EK Draft Range DP, Universal FlangePressure TransmittersView details
Datasheets & Documents
  • PDF Datasheet Yokogawa EJA120E-JES5J-912NB Draft Range DP Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJA120E-JES5J-912NB Draft Range DP

Answers from our engineering team on installation, compatibility and integration.

01What range does EJA120E-JES5J-912NB cover?
Spans of 0.1 to 1 kPa, with a range from minus 1 to 1 kPa.
02Is a process connector fitted?
No. Code 5 means the 1/4 NPT female threads on the cover flanges are used directly.
03How accurate is it?
Plus or minus 0.2 percent of span for spans of 0.4 kPa or larger, or plus or minus 0.09 percent with option HAC.
04Why must zero be trimmed after mounting?
Because a 90 degree tilt shifts zero by up to 0.4 kPa, large relative to the span of 0.1 to 1 kPa.
05Which bracket is supplied?
B is a 304 SST two-inch flat pipe bracket for horizontal piping.