Brand:

Yokogawa EJX510A In-Line Mount Absolute Pressure Transmitter

Description

Yokogawa EJX510A In-Line Mount Absolute Pressure Transmitter: overview

The Yokogawa EJX510A is a compact in-line absolute pressure transmitter from the EJX-A series. The process connection sits directly under the sensor, which removes cover flanges and impulse piping and keeps the instrument light and easy to install.

Seven Star LLC lists the Yokogawa EJX510A for engineers, maintenance planners and procurement teams in Oman and across the GCC who need to replace an installed unit, extend a loop or specify a new instrument for an oil and gas, utility, water or manufacturing project. The page below summarizes the key facts from the manufacturer datasheet so that a first technical review can be done before the full document is opened.

Key features of the EJX510A

  • EJX510A uses a single crystal silicon resonant sensor.
  • Stated reference accuracy: plus or minus 0.04% of span (span at or above the capsule limit).
  • Fast response with damping adjustable from 0.00 to 100.00 s, and a 10-segment signal characterizer for the analog output.
  • Integral LCD indicator option with 5-digit display, bar graph and local parameter setting through the external zero adjustment screw.
  • EJX multi-sensing diagnostics detect problems such as impulse line blockage or heat trace breakage, with an optional status output.
  • Cast aluminum housing as standard with IP66/IP67 and Type 4X protection, and stainless steel housing as an option.
  • SIL 2 capability for the standard HART type, so the EJX510A can be used in safety instrumented functions after the usual proof-test planning.

EJX510A technical specifications

Four capsules cover absolute pressure from 8 kPa to 50 MPa. Accuracy is plus or minus 0.04% of span, and the over pressure rating reaches 75 MPa abs on the D capsule. The datasheet quotes a long-term stability of plus or minus 0.2% of URL for 15 years for the absolute version.

Process connection options are 1/2 NPT female or male, G1/2 male and M20x1.5 male, so adapting to existing tappings is straightforward.

Multi-sensing diagnostics, an optional status output and SIL 2 certification of the standard HART type are shared with the rest of the EJX-A family.

The table lists the main values stated in the datasheet for this model. Values depend on the selected capsule, wetted material and options, so always confirm the final model code with the datasheet before ordering.

Parameter Value
Type In-line mount absolute pressure transmitter
Capsule A span 8 to 200 kPa abs (1.16 to 29 psi abs)
Capsule B span 0.02 to 2 MPa abs (2.9 to 290 psi abs)
Capsule C span 0.1 to 10 MPa abs (14.5 to 1450 psi abs)
Capsule D span 0.5 to 50 MPa abs (72.5 to 7200 psi abs)
Reference accuracy Plus or minus 0.04% of span (span at or above the capsule limit)
Stability Plus or minus 0.2% of URL for 15 years
Maximum over pressure A and B: 4 MPa abs; C: 20 MPa abs; D: 75 MPa abs
Ambient temperature -40 to 85 C (-30 to 80 C with LCD display)
Process temperature -40 to 120 C
Response time 90 ms, all capsules
Process connections 1/2 NPT female, 1/2 NPT male, G1/2 DIN 16288 male, M20x1.5 DIN 16288 male
Output 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered
Wetted parts, code S 316L SST process connector, Hastelloy C-276 diaphragm
Weight 1.2 kg for capsules A, B and C; 1.4 kg for capsule D (without indicator and bracket)

Typical applications in Oman and the GCC

  • Oil and gas. Upstream and midstream facilities use the EJX510A for gas turbine fuel-gas and lube systems, boiler steam pressure, compressor stations, process vessel pressure and instrument-air headers, where a stable digital signal and fast response help the control system and the safety layer.
  • Utilities and power. In power and utility plants across the GCC the EJX510A supports steam, feedwater, fuel gas and cooling circuits, and its diagnostics reduce unplanned inspection walks in hot plant areas.
  • Water and desalination. Desalination and water treatment plants rely on pressure and differential pressure points for pump protection and membrane skid monitoring, and a EJX510A fits those duties with materials chosen for the water chemistry.
  • Manufacturing and process. Petrochemical, fertilizer, food and general manufacturing units in Oman use the EJX510A on reactors, filters, compressors and storage, where HART or fieldbus communication feeds asset-management software.

Selection and compatibility notes

Start the selection of a EJX510A from the measured variable and the calibrated span, then pick the capsule whose upper range limit leaves comfortable margin. The datasheet shows that accuracy is quoted for spans at or above a capsule-specific value and carries an extra term for narrower spans, so very high rangedown should be checked against the formula rather than assumed.

Check the wetted materials against the process and the cleaning or flushing chemicals. Material code S with a Hastelloy C-276 diaphragm is the typical starting point, and other materials can be selected through the model code. The datasheet warns that an unsuitable material can leak process fluid or damage the diaphragm, so the choice must be made with the process conditions in hand.

Output and protocol should follow the control system. A 4 to 20 mA signal with digital communication is standard, and Fieldbus and PROFIBUS PA types have separate datasheets. For hazardous areas, review the approval options listed in the datasheet, such as FM, ATEX, CSA and IECEx, and confirm that the certificate on the nameplate matches the zone and gas group of the installation.

Installation and commissioning of the EJX510A

The EJX510A screws directly into the process connection, so thread type and sealing method should be confirmed before installation. Tighten only on the process connector hex, never on the housing, and support the instrument on a bracket when mounting on thin pipe. Because there is no impulse line, steam service needs a siphon or similar cooling element to protect the diaphragm from live steam.

After mounting, apply the electrical connection through the conduit entry, ground the housing, and power the loop. Perform a loop test and set the zero with the process isolated or the impulse lines equalized. Range the EJX510A either with a HART or BRAIN communicator or locally through the zero adjustment screw. Document the tag, range and damping in the commissioning record.

Maintenance and calibration

The EJX510A needs little routine maintenance. Check zero and span against a reference standard at an interval set by your calibration policy, inspect impulse lines and vent or drain plugs for blockage and leakage, and review the diagnostics reported by the transmitter. Keep the housing covers tight with intact O-rings, because the enclosure rating depends on them. Spare indicator and amplifier units can be changed in the field without touching the process.

Related products and ordering notes for the EJX510A

Other Yokogawa models in the same product area include EJX530A, EJX610A, EJX310A and EJA510E, which may suit neighboring points on the same plant. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model codes are used only to identify compatible equipment.

When you ask for a quotation, state the exact model code, the measuring range, the output type, any hazardous area approval and the quantity. A complete code lets us confirm that the unit matches the installed unit or the project specification, and it avoids delays caused by option mismatches.

Frequently asked questions in short

What is the Yokogawa this model? The Yokogawa this model is a in-line mount absolute pressure transmitter. The this model is a compact in-line absolute pressure transmitter from the EJX-A series. What measuring ranges does the this model cover? Datasheet values for the EJX510A: 8 to 200 kPa abs (1.16 to 29 psi abs); 0.02 to 2 MPa abs (2.9 to 290 psi abs); 0.1 to 10 MPa abs (14.5 to 1450 psi abs); 0.5 to 50 MPa abs (72.5 to 7200 psi abs). What accuracy and output does the EJX510A provide? For the EJX510A the datasheet gives plus or minus 0.04% of span (span at or above the capsule limit). Output and communication: 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered.

Documents and quotation

The manufacturer datasheet for the EJX510A is attached to this page and gives the complete model and suffix codes, dimensions and options. To receive a quotation, send the RFQ with the part number EJX510A, the quantity and your required range and approvals, and the Seven Star LLC team will reply with availability and delivery information for Oman and the GCC.

Other Models in the Yokogawa Inline Range

Seven Star LLC supplies models from the Yokogawa Inline range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa EJA510E In-Line Mount Absolute Pressure TransmitterPressure TransmittersView details
Yokogawa EJX510A In-Line Mount Absolute Pressure TransmitterPressure TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa EJX510A In-Line Mount Absolute Pressure Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJX510A In-Line Mount Absolute Pressure

Answers from our engineering team on installation, compatibility and integration.

01What is the Yokogawa EJX510A?
The Yokogawa EJX510A is a in-line mount absolute pressure transmitter. The EJX510A is a compact in-line absolute pressure transmitter from the EJX-A series.
02What measuring ranges does the EJX510A cover?
Datasheet values for the EJX510A: 8 to 200 kPa abs (1.16 to 29 psi abs); 0.02 to 2 MPa abs (2.9 to 290 psi abs); 0.1 to 10 MPa abs (14.5 to 1450 psi abs); 0.5 to 50 MPa abs (72.5 to 7200 psi abs).
03What accuracy and output does the EJX510A provide?
For the EJX510A the datasheet gives plus or minus 0.04% of span (span at or above the capsule limit). Output and communication: 4 to 20 mA DC with HART or BRAIN; FOUNDATION Fieldbus and PROFIBUS PA also offered.
04How is the EJX510A connected to the process?
The EJX510A screws directly into the process tapping, with thread options listed in the datasheet, and needs no manifold or cover flange. It should be supported with a bracket on thin pipe.
05How can I request a quotation for the EJX510A in Oman?
Send an RFQ with the part number EJX510A, quantity, range, output and approvals through the inquiry form. Seven Star LLC replies with availability and delivery for Oman and the GCC, and the datasheet is on the product page.