Brand: Yokogawa
Yokogawa EJA115E-DHS2J-312DD-N00NN0 Low Flow BRAIN
Description
Rc1/2, BRAIN and the H capsule: EJA115E-DHS2J-312DD-N00NN0
Three choices set this transmitter apart from the standard configuration, and they are exactly the ones that make Yokogawa EJA115E-DHS2J-312DD-N00NN0 a spare-parts item rather than a catalogue default. The output is BRAIN (code D) rather than HART, the process connections are Rc1/2 female (code 2) rather than NPT, and the capsule is the H type with a 20 to 210 kPa span. A digital indicator, a 304 SST L-type bracket and vertical installation with right-side high pressure and manifold downside complete the build.
Code positions of EJA115E-DHS2J-312DD-N00NN0
| Code position | Meaning |
|---|---|
| -D | 4 to 20 mA DC with BRAIN digital communication |
| H | Capsule: span 20 to 210 kPa |
| S | Wetted parts: cover flange and process connector ASTM CF-8M, Hastelloy C-276 diaphragm, 316L SST others, PTFE orifice gasket |
| 2 | Process connection: Rc1/2 female |
| J | Bolts and nuts: B7 carbon steel for cover flange and connector, 316L SST for manifold |
| -3 | Installation: vertical piping, right side high pressure, manifold downside |
| 1 | Amplifier housing: cast aluminum alloy |
| 2 | Electrical: 1/2 NPT female, two electrical connections, no blind plugs |
| D | Integral indicator: digital indicator |
| D | Mounting bracket: 304 SST 2-inch pipe bracket, L type (vertical piping) |
| -N00NN0 | Fixed trailing code, always the same for this model |
H capsule data
Reference accuracy is plus or minus 0.055 percent of span for spans of 100 kPa or more, with a term of 0.005 plus 0.01 times URL over span for narrower spans. URL is 500 kPa. Ambient effect is plus or minus (0.07 percent span plus 0.015 percent URL) per 28 degrees C. Static pressure effect on zero is plus or minus 0.028 percent of URL for M and H capsules per 6.9 MPa. Response time is 90 ms. Water-equivalent flow ranges run from 0.07 to 0.225 l/min at a 0.508 mm bore to 10 to 33 l/min at 6.350 mm; air ranges from 1.98 to 6.4 up to 280 to 910 Nl/min.
Facts and figures: EJA115E-DHS2J-312DD-N00NN0
| Item | Value |
|---|---|
| Output | 4 to 20 mA with BRAIN communication |
| Capsule H | 20 to 210 kPa; URL 500 kPa |
| Connection | Rc1/2 female |
| Bolts | B7 carbon steel on flange and connector, 316L SST on manifold |
| Installation | -3: vertical piping, right side high pressure, manifold downside |
| Indicator | D digital LCD |
| Bracket | D, 304 SST L type |
| MWP | 16 MPa |
| Burst | 69 MPa |
| Response | 90 ms |
Choosing BRAIN
BRAIN communication allows remote setup by BRAIN terminal and compatible hosts at up to 2 km on CEV polyethylene-insulated PVC-sheathed cable. HART replaces it in newer systems, but plants with a BRAIN fleet can keep a single tool. The output signal still reaches the DCS as 4 to 20 mA.
Rc versus NPT
Rc1/2 is a tapered female thread in the ISO 7 family, different from 1/2 NPT; mixing the two risks leaks. Use the thread that matches your piping.
Fitting
Mount the 304 SST L-type bracket on a vertical two-inch pipe, since installation code 3 describes vertical piping with the high-pressure side on the right and the manifold below the capsule. Connect the process through the Rc1/2 female ports with fittings that suit the thread, tighten the manifold plugs, and wire through one 1/2 NPT conduit entry. BRAIN communication needs at least 16.6 V DC at the terminals and a loop resistance of 250 to 600 ohm, so check the supply and any barrier. After wiring, equalize the two sides, trim zero and run a loop test through the BRAIN terminal before opening the process valves.
With a micro orifice built into the body, the most common fault is partial blockage by scale or particles, so keep the line clean and filtered upstream. Verify zero at each shutdown with both sides equalized, review the self-diagnostic status through the BRAIN terminal and keep the cover O-rings in good condition. If a spare of this exact code is installed after a failure, record the new serial number against the loop tag.
Selection and ordering notes for EJA115E-DHS2J-312DD-N00NN0
Spare-part buyers often ask whether an Rc1/2 unit can be replaced with a 1/2 NPT unit. Mechanically it is possible only with adapters, and extra joints add leak points on low-flow lines where small errors matter. For this reason the exact code EJA115E-DHS2J-312DD-N00NN0 is requested rather than a nearby one. The H capsule is also a mid-to-high range element in this family, suited to flows that produce differential pressure up to 210 kPa; for lower flows the M or F capsule would be selected, with different part numbers. Slash options are separate: for example /N2 and /N3 give fluorinated rubber process connector gaskets, and /A adds a lightning protector for 10.5 to 32 V DC supply.
Quick answers about EJA115E-DHS2J-312DD-N00NN0
- What is the process connection of EJA115E-DHS2J-312DD-N00NN0? Rc1/2 female, selected by code 2 in the process connection position of the suffix.
- What protocol does D select? The leading D selects a 4 to 20 mA DC output with BRAIN digital communication; HART would be code J.
- Which capsule is used? The H capsule, which gives a differential pressure span of 20 to 210 kPa with a 500 kPa upper range limit.
- What bracket is included? D, a 304 SST L-type two-inch pipe bracket for vertical piping.
- How is the orifice bore chosen? The bore is specified together with the flow data when ordering; the datasheet lists bores from 0.508 to 6.350 mm.
Documents and quotation
Please state the thread type in your inquiry.
Yokogawa general specification GS 01C31K01-01EN for the EJA115E low flow transmitter is supplied as the datasheet PDF with this listing. Send the full part number EJA115E-DHS2J-312DD-N00NN0, the quantity, the tag numbers and, because an integral orifice is calibrated to the flow case, the flow data or orifice bore you need. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Availability and lead time are confirmed per RFQ.
Other Models in the EJA115E Range
Seven Star LLC supplies models from the EJA115E range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Yokogawa EJA115E-JMS4J-912NB-N00NN0 Low Flow Transmitter | Pressure Transmitters | View details |
| Yokogawa EJA115E-JFS4G-712EK-N00NN0 F Capsule Low Flow | Pressure Transmitters | View details |
| Yokogawa EJA115E-DHS2J-312DD-N00NN0 Low Flow BRAIN | Pressure Transmitters | You are viewing this model |
Datasheets & Documents
- Datasheet Yokogawa EJA115E-DHS2J-312DD-N00NN0 Low Flow BRAIN Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa EJA115E-DHS2J-312DD-N00NN0 Low Flow BRAIN
Answers from our engineering team on installation, compatibility and integration.
01What is the process connection of EJA115E-DHS2J-312DD-N00NN0?
Rc1/2 female, selected by code 2 in the process connection position of the suffix.
02What protocol does D select?
The leading D selects a 4 to 20 mA DC output with BRAIN digital communication; HART would be code J.
03Which capsule is used?
The H capsule, which gives a differential pressure span of 20 to 210 kPa with a 500 kPa upper range limit.
04What bracket is included?
D, a 304 SST L-type two-inch pipe bracket for vertical piping.
05How is the orifice bore chosen?
The bore is specified together with the flow data when ordering; the datasheet lists bores from 0.508 to 6.350 mm.