- Automation & ControlView all 2,953 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Yokogawa
Yokogawa EJA530E-DAS4N-012NN Gauge Pressure Transmitter
Description
The reference code: Yokogawa EJA530E-DAS4N-012NN
Yokogawa prints one example of a complete model code in the EJA530E datasheet, and it is EJA530E-DAS4N-012NN. That alone explains why the number is requested so often: it is the typical configuration the company itself illustrates. It describes an in-line gauge pressure transmitter with the lowest-pressure A capsule, BRAIN protocol on the 4 to 20 mA loop, 316L stainless wetted parts with a Hastelloy C-276 diaphragm, a 1/2 NPT female process port, an aluminum housing and two 1/2 NPT conduit entries. There is no indicator and no bracket.
Because the D output code uses BRAIN rather than HART, this is a unit for plants whose terminals and host systems already use BRAIN, and for engineers who simply want to keep an existing loop configuration.
Position-by-position reading of EJA530E-DAS4N-012NN
| Code position | Meaning |
|---|---|
| -D | 4 to 20 mA DC with BRAIN digital communication |
| A | Capsule: span 10 to 200 kPa |
| S | 316L SST process connector, Hastelloy C-276 diaphragm, 316L SST or F316L SST other wetted parts |
| 4 | Process connection: 1/2 NPT female |
| 1 | Amplifier housing: cast aluminum alloy |
| 2 | Electrical: 1/2 NPT female, two electrical connections, no blind plugs |
| N | Integral indicator: none |
| N | Mounting bracket: none |
Low-pressure behaviour of the A capsule
The A capsule spans 10 to 200 kPa, with a range limit from minus 100 kPa to 200 kPa since the EJA530E is a gauge unit; the upper range limit and maximum working pressure are both 200 kPa (29 psig), and over-pressure is 4 MPa. Accuracy is plus or minus 0.055 percent of span at spans of 20 kPa or larger, and below that the datasheet applies a term proportional to URL over span. Stability is plus or minus 0.1 percent of URL for 10 years. Because capsule A is the most sensitive, tilting the transmitter 90 degrees can move zero by up to 0.21 kPa, a noticeable fraction of a 10 kPa span.
Electrical and environmental data of EJA530E-DAS4N-012NN
| Item | Value |
|---|---|
| Output | 4 to 20 mA DC, BRAIN protocol (code D) |
| Output range | 3.6 to 21.6 mA |
| Failure alarm | Up-scale 110 percent (21.6 mA or more) or down-scale minus 5 percent (3.2 mA or less) |
| Supply | 10.5 to 42 V DC, minimum 16.6 V for communication |
| Loop load | 0 to 1290 ohm; 250 to 600 ohm for communication |
| BRAIN cable length | Up to 2 km with CEV polyethylene PVC-sheathed cable |
| Ambient temperature | Minus 40 to 85 degrees C |
| Process temperature | Minus 40 to 120 degrees C |
| Protection | IP66/IP67, Type 4X |
| Burst pressure | 30 MPa (A, B and C capsules) |
| Weight | 1.2 kg without indicator or bracket |
Typical duties for EJA530E-DAS4N-012NN
Low-range gauge pressure turns up in boiler furnace purge checks, filter differential supervision where the other side is atmospheric, flare header and blower discharge monitoring, tank blanket pressure on nitrogen padded storage, and HVAC air handling for utility buildings. Under 200 kPa, the 1/2 NPT female thread is easy to connect with tube or pipe fittings.
Why BRAIN instead of HART
The suffix character D selects BRAIN. It is read with a BRAIN terminal or with host systems that support the BRAIN protocol. HART, code J, is the common choice for new multi-vendor systems. If your DCS input card is a plain 4 to 20 mA card and you use a handheld that speaks BRAIN, EJA530E-DAS4N-012NN is the match. Switching between protocols in the field is not possible; the choice is made at manufacture.
Mounting and start-up
Because no bracket is part of EJA530E-DAS4N-012NN, direct mounting on a rigid pipe or an instrument stand is common. Connect with the 1/2 NPT female thread using a suitable sealant, keep the process port from collecting liquid when gas is measured, and close the covers fully after wiring. Apply known low pressure and adjust zero with the external screw, which has 0.01 percent resolution of span.
Avoid blowing air into the port for cleaning, since a single mistaken pulse above 4 MPa is beyond the over-pressure rating. Replace weathered O-rings in the amplifier cover if you see swelling; fluoro-rubber O-rings are an option.
Related variants of EJA530E-DAS4N-012NN
The same housing and electronics are shared by every EJA530E code, so spare covers, indicators and amplifier assemblies follow the family and not the capsule. What changes EJA530E-DAS4N-012NN into a different part number is any one position in the suffix: swapping A for B moves the span window to 0.02 to 2 MPa, changing 4 for 7 turns the port into a male thread, changing D for J swaps BRAIN for HART, and adding D or E in the ninth position adds an indicator. Slash options such as /A lightning protector, /HAC high accuracy of plus or minus 0.04 percent of span, /C2 and /C3 NAMUR output limits, or /D1 psi calibration create further distinct orders, so mention them if your nameplate shows them.
Nameplates also carry a tag and a calibrated range. Send a photo if you can, because the calibrated range tells us whether the unit was supplied with a calibration option.
Quick answers about EJA530E-DAS4N-012NN
- Why is EJA530E-DAS4N-012NN considered the typical code? Yokogawa lists it as the example model code in the datasheet, with arrow-marked typical selections in each position.
- Does the D in EJA530E-DAS4N-012NN mean digital or HART? No. D selects 4 to 20 mA with BRAIN digital communication; J would select HART.
- What is the pressure range of this unit? The A capsule gives a span of 10 to 200 kPa with a range from minus 100 to 200 kPa gauge.
- What is the over-pressure rating for capsule A? 4 MPa according to the datasheet, with 30 MPa burst pressure for A, B and C capsules.
- Can I mount EJA530E-DAS4N-012NN without a bracket? Yes. The bracket position is N, so no bracket is supplied and the transmitter is mounted directly or on a separately ordered bracket.
Documents and quotation
The base code is quoted without optional slash codes.
Attach or request the Yokogawa general specification GS 01C31F01-01EN for this family; it is provided as the datasheet PDF with the product listing. Your RFQ should state the part number EJA530E-DAS4N-012NN, quantity, tag numbers, process medium and any hazardous-area approval. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Availability and delivery are confirmed per enquiry.
Datasheets & Documents
- Datasheet Yokogawa EJA530E-DAS4N-012NN Gauge Pressure Transmitter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa EJA530E-DAS4N-012NN Gauge Pressure
Answers from our engineering team on installation, compatibility and integration.
01Why is EJA530E-DAS4N-012NN considered the typical code?
Yokogawa lists it as the example model code in the datasheet, with arrow-marked typical selections in each position.
02Does the D in EJA530E-DAS4N-012NN mean digital or HART?
No. D selects 4 to 20 mA with BRAIN digital communication; J would select HART.
03What is the pressure range of this unit?
The A capsule gives a span of 10 to 200 kPa with a range from minus 100 to 200 kPa gauge.
04What is the over-pressure rating for capsule A?
4 MPa according to the datasheet, with 30 MPa burst pressure for A, B and C capsules.
05Can I mount EJA530E-DAS4N-012NN without a bracket?
Yes. The bracket position is N, so no bracket is supplied and the transmitter is mounted directly or on a separately ordered bracket.


















Reviews