- Automation & ControlView all 2,760 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Pneumatic Cylinders
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Yokogawa
Yokogawa EJA115E Low Flow Transmitter with Integral Orifice
Description
Yokogawa EJA115E Low Flow Transmitter with Integral Orifice: overview
The Yokogawa EJA115E combines a differential pressure sensor with an integral orifice in one body, so very small liquid, gas or steam flows can be measured without building a separate orifice run. It belongs to the Yokogawa EJA-E family and shares the same amplifier, HART or BRAIN communication and self-diagnostics as the larger members of the range.
Seven Star LLC lists the Yokogawa EJA115E for engineers, maintenance planners and procurement teams in Oman and across the GCC who need to replace an installed unit, extend a loop or specify a new instrument for an oil and gas, utility, water or manufacturing project. The page below summarizes the key facts from the manufacturer datasheet so that a first technical review can be done before the full document is opened.
Key features of the EJA115E
- EJA115E pairs a stable pressure sensor with an integral orifice for very low flows.
- Stated reference accuracy: plus or minus 0.055% of span for all capsules when the span is at or above the stated limit.
- Fast response with damping adjustable from 0.00 to 100.00 s, and a 10-segment signal characterizer for the analog output.
- Integral LCD indicator option with 5-digit display, bar graph and local parameter setting through the external zero adjustment screw.
- Self-diagnostics for CPU failure, hardware failure, configuration errors and over-range, with user-configurable process high and low alarms.
- Cast aluminum housing as standard with IP66/IP67 and Type 4X protection, and stainless steel housing as an option.
- SIL 2 capability for the standard HART type, so the EJA115E can be used in safety instrumented functions after the usual proof-test planning.
EJA115E technical specifications
Three capsules cover the range. The F capsule spans 1 to 5 kPa and is the usual choice for the smallest flows, the M capsule spans 2 to 100 kPa, and the H capsule spans 20 to 210 kPa. The datasheet gives water-equivalent and air-equivalent flow ranges for every capsule, which makes first-pass sizing quick. Because the integral orifice has a stated accuracy of plus or minus 5% of span, the instrument suits process control and monitoring rather than fiscal measurement.
Besides differential pressure, the sensor also measures static pressure. The static pressure value can be shown on the integral indicator or read remotely through BRAIN or HART, with a stated accuracy of plus or minus 0.5% of span for absolute pressure at 1 MPa or higher.
Update period is 45 ms for differential pressure and 360 ms for static pressure, with damping adjustable from 0.00 to 100.00 s.
The table lists the main values stated in the datasheet for this model. Values depend on the selected capsule, wetted material and options, so always confirm the final model code with the datasheet before ordering.
| Parameter | Value |
|---|---|
| Type | Differential pressure transmitter with integral orifice for very low flow |
| Capsule F span | 1 to 5 kPa (100 to 500 mmH2O); water equivalent 0.016 to 5.0 l/min; air 0.44 to 140 Nl/min |
| Capsule M span | 2 to 100 kPa (200 to 10000 mmH2O); water 0.022 to 23.0 l/min; air 0.63 to 635 Nl/min |
| Capsule H span | 20 to 210 kPa (2000 to 21000 mmH2O); water 0.07 to 33.0 l/min; air 2.0 to 910 Nl/min |
| Integral orifice accuracy | Plus or minus 5% of span |
| Reference accuracy (differential pressure) | Plus or minus 0.055% of span for all capsules when the span is at or above the stated limit |
| Maximum working pressure | 16 MPa (2300 psi), all capsules |
| Burst pressure limit (transmitter part) | 69 MPa (10,000 psi) |
| Ambient temperature | -40 to 85 C (-30 to 80 C with LCD display) |
| Process temperature | -40 to 120 C |
| Response time | 90 ms for M and H capsules, 150 ms for F capsule |
| Stability (M and H) | Plus or minus 0.1% of URL per 10 years |
| Output | 4 to 20 mA DC with HART or BRAIN; Fieldbus, PROFIBUS PA and 1 to 5 V low-power HART also offered |
| Wetted parts, code S | Cover flange and process connector ASTM CF-8M, Hastelloy C-276 diaphragm, 316 SST orifice |
| Weight | 4.5 kg for M and H capsules, 5.4 kg for F capsule (without indicator and bracket) |
Typical applications in Oman and the GCC
- Oil and gas. Upstream and midstream facilities use the EJA115E for small chemical-injection lines, lube-oil and seal-oil circuits, sample conditioning loops, boiler chemical dosing and laboratory-scale pilot plants, where a stable digital signal and fast response help the control system and the safety layer.
- Utilities and power. In power and utility plants across the GCC the EJA115E supports steam, feedwater, fuel gas and cooling circuits, and its diagnostics reduce unplanned inspection walks in hot plant areas.
- Water and desalination. Desalination and water treatment plants rely on pressure and differential pressure points for pump protection and membrane skid monitoring, and a EJA115E fits those duties with materials chosen for the water chemistry.
- Manufacturing and process. Petrochemical, fertilizer, food and general manufacturing units in Oman use the EJA115E on reactors, filters, compressors and storage, where HART or fieldbus communication feeds asset-management software.
Selection and compatibility notes
Start the selection of a EJA115E from the measured variable and the calibrated span, then pick the capsule whose upper range limit leaves comfortable margin. The datasheet shows that accuracy is quoted for spans at or above a capsule-specific value and carries an extra term for narrower spans, so very high rangedown should be checked against the formula rather than assumed.
Check the wetted materials against the process and the cleaning or flushing chemicals. Material code S with a Hastelloy C-276 diaphragm is the typical starting point, and other materials can be selected through the model code. The datasheet warns that an unsuitable material can leak process fluid or damage the diaphragm, so the choice must be made with the process conditions in hand.
Output and protocol should follow the control system. A 4 to 20 mA signal with digital communication is standard, and Fieldbus and PROFIBUS PA types have separate datasheets. For hazardous areas, review the approval options listed in the datasheet, such as FM, ATEX, CSA and IECEx, and confirm that the certificate on the nameplate matches the zone and gas group of the installation.
Installation and commissioning of the EJA115E
Mount the EJA115E on a rigid bracket or directly on a manifold, with the process connections oriented to suit the impulse line slope. Use a three-valve or five-valve manifold so that the transmitter can be isolated, equalized and zeroed without breaking process connections. For gas service, mount above the tapping points; for liquids, mount below, and keep both impulse lines at the same temperature to avoid false differential readings.
After mounting, apply the electrical connection through the conduit entry, ground the housing, and power the loop. Perform a loop test and set the zero with the process isolated or the impulse lines equalized. Range the EJA115E either with a HART or BRAIN communicator or locally through the zero adjustment screw. Document the tag, range and damping in the commissioning record.
Maintenance and calibration
The EJA115E needs little routine maintenance. Check zero and span against a reference standard at an interval set by your calibration policy, inspect impulse lines and vent or drain plugs for blockage and leakage, and review the diagnostics reported by the transmitter. Keep the housing covers tight with intact O-rings, because the enclosure rating depends on them. Spare indicator and amplifier units can be changed in the field without touching the process.
Related products and ordering notes for the EJA115E
Other Yokogawa models in the same product area include EJA110E, EJA120E, EJA130E and EJX115A, which may suit neighboring points on the same plant. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model codes are used only to identify compatible equipment.
When you ask for a quotation, state the exact model code, the measuring range, the output type, any hazardous area approval and the quantity. A complete code lets us confirm that the unit matches the installed unit or the project specification, and it avoids delays caused by option mismatches.
Frequently asked questions in short
What is the Yokogawa this model? The Yokogawa this model is a low-flow differential pressure transmitter with an integral orifice. The this model combines a differential pressure sensor with an integral orifice in one body, so very small liquid, gas or steam flows can be measured without building a separate orifice run. What measuring ranges does the this model cover? Datasheet values for the EJA115E: 1 to 5 kPa (100 to 500 mmH2O); water equivalent 0.016 to 5.0 l/min; air 0.44 to 140 Nl/min; 2 to 100 kPa (200 to 10000 mmH2O); water 0.022 to 23.0 l/min; air 0.63 to 635 Nl/min; 20 to 210 kPa (2000 to 21000 mmH2O); water 0.07 to 33.0 l/min; air 2.0 to 910 Nl/min. What accuracy and output does the EJA115E provide? For the EJA115E the datasheet gives plus or minus 0.055% of span for all capsules when the span is at or above the stated limit. Output and communication: 4 to 20 mA DC with HART or BRAIN; Fieldbus, PROFIBUS PA and 1 to 5 V low-power HART also offered.
For a replacement or a new project, quote the EJA115E by its full model code so that the right capsule and options are confirmed.
Documents and quotation
The manufacturer datasheet for the EJA115E is attached to this page and gives the complete model and suffix codes, dimensions and options. To receive a quotation, send the RFQ with the part number EJA115E, the quantity and your required range and approvals, and the Seven Star LLC team will reply with availability and delivery information for Oman and the GCC.
Other Models in the Yokogawa Lowflow Range
Seven Star LLC supplies models from the Yokogawa Lowflow range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Yokogawa EJA115E Low Flow Transmitter with Integral Orifice | Pressure Transmitters | You are viewing this model |
| Yokogawa EJX115A Low Flow Transmitter with Integral Orifice | Pressure Transmitters | View details |
Datasheets & Documents
- Datasheet Yokogawa EJA115E Low Flow Transmitter with Integral Orifice Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa EJA115E Low Flow Transmitter with Integral
Answers from our engineering team on installation, compatibility and integration.
01What is the Yokogawa EJA115E?
The Yokogawa EJA115E is a low-flow differential pressure transmitter with an integral orifice. The EJA115E combines a differential pressure sensor with an integral orifice in one body, so very small liquid, gas or steam flows can be measured without building a separate orifice run.
02What measuring ranges does the EJA115E cover?
Datasheet values for the EJA115E: 1 to 5 kPa (100 to 500 mmH2O); water equivalent 0.016 to 5.0 l/min; air 0.44 to 140 Nl/min; 2 to 100 kPa (200 to 10000 mmH2O); water 0.022 to 23.0 l/min; air 0.63 to 635 Nl/min; 20 to 210 kPa (2000 to 21000 mmH2O); water 0.07 to 33.0 l/min; air 2.0 to 910 Nl/min.
03What accuracy and output does the EJA115E provide?
For the EJA115E the datasheet gives plus or minus 0.055% of span for all capsules when the span is at or above the stated limit. Output and communication: 4 to 20 mA DC with HART or BRAIN; Fieldbus, PROFIBUS PA and 1 to 5 V low-power HART also offered.
04Which accessories are normally used with the EJA115E?
The EJA115E is normally installed with a three-valve or five-valve manifold, impulse piping and a mounting bracket, plus a HART communicator or configuration software for ranging and diagnostics.
05How can I request a quotation for the EJA115E in Oman?
Send an RFQ with the part number EJA115E, quantity, range, output and approvals through the inquiry form. Seven Star LLC replies with availability and delivery for Oman and the GCC, and the datasheet is on the product page.


















Reviews
There are no reviews yet.