Schneider Electric MCSESM083F23F0 8-Port Managed Switch

Description

MCSESM083F23F0: an eight-port managed Modicon switch

The MCSESM083F23F0 is a managed Ethernet TCP/IP switch from the Schneider Electric Modicon Networking range. The datasheet describes it as a managed switch with 8 ports for copper, each 10/100BASE-TX, built for DIN-rail mounting and supplied from a 12–24 V DC source. Where an unmanaged switch only forwards frames, this one can be configured, monitored and hardened, which is the reason to choose it for a control network that carries more than a handful of devices.

The datasheet places the product in the Modicon Networking TF switch cabling system. It supports a long list of management and industrial protocols, and it is aimed at networks where redundancy and cybersecurity are specified rather than assumed.

MCSESM083F23F0 technical specifications

Parameter Specification
Manufacturer / part number Schneider Electric / MCSESM083F23F0
Range Modicon Networking
Product type Ethernet TCP/IP managed switch
Ethernet ports 8 x 10/100BASE-TX, shielded RJ45 copper
Cable Twisted shielded pairs, CAT 5E; up to 100 m between devices
Supply voltage 12–24 V (limits 9.6–32 V DC SELV)
Power consumption 6 W
Power connector Removable, 6-way
Mounting 35 mm symmetrical DIN rail
Dimensions W × H × D 73 × 142.8 × 117.6 mm
Net weight 0.42 kg
Protection IP30
Operating temperature 0–60 °C
Relative humidity 1–95 %, non-condensing
MTBF 4,467,842 h
Alarm output 1 volt-free contact, 1 A
Switches in a ring Up to 50
Standards UL 61010-2-201; EN/IEC 61131-2; IEC 61850-3; IEC 62443-4-2; EN 50121-4

Cybersecurity and management features of the MCSESM083F23F0

Management is by web server, and the datasheet lists the services as VLAN, multicast filtering, IGMP snooping, data stream control, QoS, port monitoring and mirroring, address conflict detection, TFTP, SNMP traps and SYSLOG. The communication protocols include SSH, HTTP, HTTPS, SNMP, SFTP, SCP, LLDP, Telnet, SNTP, Modbus TCP, OPC UA and an IEC 61850 MMS server.

Area Listed in the datasheet
Access control Role-based access control; RADIUS assignment; TACACS+; port-based access control
Port security Port hardening; IP-based and MAC-based port security
Traffic protection DoS prevention; VLAN-based ACL
Logging and audit Audit trail; SNMP logging; pre-login banner
Secure transport HTTPS; SSH; SFTP; SCP

Disabling unused services such as Telnet and HTTP is a normal hardening step once secure alternatives are in place; the datasheet lists both so the choice is left to the integrator.

Redundancy options on the MCSESM083F23F0

A control network that stops when one cable is cut is a risk that most plants try to remove. The datasheet lists the redundancy methods this switch supports: HiPER ring, RSTP, MSTP, MRP, link aggregation, link backup, redundant network coupling and a redundant coupling protocol. Up to 50 switches can be placed in one ring.

The practical consequence is that the MCSESM083F23F0 can be used as one node in a ring of managed switches, with the ring recovering when a link fails. Which protocol to use is a design decision, because mixed-vendor rings usually need a standard such as RSTP or MRP, while a single-vendor ring can use the faster proprietary method. The datasheet does not state recovery times, so those must be taken from the network design documents.

Diagnostics, alarms and front-panel signalling

For maintenance staff the MCSESM083F23F0 reports problems in several ways. The signal contact is a volt-free output rated 1 A, and the alarm functions listed are power supply fault, data link status, switch fault, temperature threshold, redundancy ring fault, incorrect configuration and external memory removed. Diagnostic functions include self-test, MAC notification, RSPAN and sFlow.

On the front there are dual-colour LEDs for the P1 and P2 power supplies, device status, memory key status and channel diagnostics. Reports for security status, alarms and system information are available as functions of the device.

Power, mounting and environment for the MCSESM083F23F0

The switch takes 12–24 V DC with limits of 9.6–32 V DC SELV through a removable six-way connector, and the datasheet quotes 6 W consumption. Two supply inputs are indicated on the front, P1 and P2, so a redundant power feed can be used. The housing measures 73 mm wide, 142.8 mm high and 117.6 mm deep, weighs 0.42 kg and clips to a 35 mm DIN rail.

Operation is rated from 0 to 60 °C at 1–95 % non-condensing humidity with IP30 protection, so it needs a closed panel or cabinet in dusty or wet conditions. The product lists CE, UL, RCM, DNV, ATEX, EAC, UKCA, CSA C22-2 No 213, UKEX, FCC part 15 class A and CCC Ex among its certifications.

Where the MCSESM083F23F0 fits in a control network

An eight-port managed switch is typically the access or distribution layer inside a machine room, skid or substation. It links PLCs, drives, HMIs, remote I/O and a SCADA uplink, and with IEC 61850 listed among its standards it can also appear in substation automation designs. When there are only a few devices and no ring or security requirement, the five-port unmanaged MCSESU053FN0 is the simpler alternative.

A common arrangement is two or more MCSESM083F23F0 units connected as a ring, with field devices on the copper ports and one port used as a link to the plant network. The switch has copper ports only, so fibre uplinks need a different model.

Selection checklist and RFQ details for the MCSESM083F23F0

  • Part number MCSESM083F23F0 and quantity
  • Number of copper ports needed now and in the future (this unit has 8)
  • Redundancy scheme used in the network: ring protocol, number of switches
  • Management and security requirements: VLANs, RADIUS or TACACS+, SNMP version, audit logging
  • Supply voltage and whether two power feeds are used
  • Cabinet temperature and DIN-rail space (73 mm width)
  • Delivery place in Oman or the GCC and required date

Using the MCSESM083F23F0 in Oman and the GCC

Managed industrial switches of this kind are found in oil and gas control rooms, power stations and substations, desalination and water treatment plants, and large building automation systems across the Gulf. The environment drives the cabinet decision: the switch tolerates 60 °C ambient, but a sealed cabinet in direct sun can exceed that, and fine dust is common. Security rules for process networks are also tightening, which is when features like role-based access and audit trails become requirements.

Documents and quotation

The Schneider Electric manufacturer datasheet for the MCSESM083F23F0 is attached on this page as a PDF. It is the reference for every rating quoted above, and it is worth checking the revision against your project documents before an order is placed. Protocol lists, certifications and dimensions are all in the document.

Seven Star LLC is an independent supplier in Muscat that serves buyers in Oman and the GCC. Send the part number MCSESM083F23F0, the quantity and the delivery site, and we will reply with a quotation and the availability we can confirm.

Other Models in the Se Modicon Switch Range

Seven Star LLC supplies models from the Se Modicon Switch range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric MCSESM083F23F0 8-Port Managed SwitchIndustrial CommunicationsYou are viewing this model
Schneider Electric MCSESU053FN0 5-Port Unmanaged SwitchIndustrial CommunicationsView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric MCSESM083F23F0 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric MCSESM083F23F0 8-Port Managed

Answers from our engineering team on installation, compatibility and integration.

01How many ports does the MCSESM083F23F0 have?
Eight 10/100BASE-TX copper ports with shielded RJ45 connectors. The datasheet lists copper ports only and a maximum cable length of 100 m between devices.
02Which redundancy protocols does the MCSESM083F23F0 support?
HiPER ring, RSTP, MSTP, MRP, link aggregation, link backup, redundant network coupling and a redundant coupling protocol. Up to 50 switches can be used in a ring.
03What supply voltage does the MCSESM083F23F0 need?
12 to 24 V DC with limits of 9.6 to 32 V DC SELV, through a removable 6-way connector. Power consumption is 6 W.
04What cybersecurity features does the MCSESM083F23F0 list?
Port hardening, IP- and MAC-based port security, role-based and port-based access control, RADIUS, TACACS+, HTTPS, DoS prevention, VLAN-based ACL, audit trail and pre-login banner.
05What are the size and temperature range of the MCSESM083F23F0?
73 x 142.8 x 117.6 mm (W x H x D), weight 0.42 kg, DIN-rail mounting. Operation is 0 to 60 degrees C with IP30 protection.