Brand:

SCALANCE XC-100

Description

The SCALANCE XC-100 is a compact and rugged unmanaged industrial Ethernet switch, ideal for use in demanding automation environments. Manufactured by Siemens, this switch ensures stable and high-performance network communication in industries such as manufacturing, power, oil & gas, and transportation.

Designed for applications requiring high mechanical and electromagnetic resilience, the SCALANCE XC-100 series offers several port configurations with Fast Ethernet (10/100 Mbps) support, allowing integration into existing and new industrial networks. These devices are DIN rail-mountable and operate reliably in extended temperature ranges, making them suitable for outdoor cabinets and production floors.

A major advantage of the SCALANCE XC-100 is its fanless design and compact enclosure, which ensures reliable operation in dust-prone or vibration-intense environments. It requires no software configuration, enabling simple plug-and-play deployment for rapid commissioning. This makes the switch an ideal solution for engineers seeking reliable Ethernet connectivity without the need for advanced management features.

The SCALANCE XC-100 models are equipped with LED indicators for each port, which provide real-time status updates and simplify diagnostics and maintenance. Their robust build complies with industrial standards and provides protection against vibration, shock, and electromagnetic interference.

The SCALANCE XC-100 also supports redundant power supply options, which enhances availability and minimizes the risk of network downtime. Its wide range of certifications (e.g., CE, UL, cULus) ensures compatibility with global industrial requirements, and its compact design saves valuable panel space.

This industrial Ethernet switch is commonly used in applications such as machine building, factory automation, and process industries where reliable and continuous data transmission is essential. It plays a crucial role in connecting PLCs, HMIs, sensors, and other field devices within a secure and resilient communication infrastructure.

In conclusion, the SCALANCE XC-100 is a trusted solution for unmanaged Ethernet switching in harsh environments. Its durability, ease of use, and consistent performance make it a preferred choice for engineers aiming to build robust and future-proof industrial networks.

Technical Specifications

Per Siemens’ official SCALANCE XC-100 documentation, the family covers several port-count variants:

XC106-2 (SC/ST) 6x 10/100 Mbps RJ-45 + 2x 10/100 Mbps fiber (multimode)
XC108 8x 10/100 Mbps RJ-45
XC116 16x 10/100 Mbps RJ-45
XC124 24x 10/100 Mbps RJ-45
Switching type Unmanaged; up to 2048 learnable MAC addresses; IEEE 802.1Q VLAN tag transparent forwarding
Power supply 12-24 V DC, redundant inputs; current draw 125 mA (XC108) to 650 mA (XC124) at 12 V
Operating temperature -40°C to +70°C
Certifications ATEX/IECEx/UKEX/CCC Ex II 3 G Ex ec IIC T4 Gc (Zone 2); FM Class I Div. 2; cULus; RoHS/EMC

Why Unmanaged Fits Machine-Level Networking

Because the XC-100 series requires no configuration, it can be installed and put into service by an electrician or automation technician without dedicated network engineering support — appropriate for a machine-level segment where the switch simply needs to connect a fixed set of PLCs, HMIs, sensors, and I/O devices reliably, rather than support VLANs, managed redundancy protocols, or remote diagnostics. Where a network segment needs those managed capabilities, Siemens’ SCALANCE X-200/X-300 managed switch families are the appropriate step up rather than the XC-100.

Industrial Applications

The SCALANCE XC-100 is deployed at the machine or cell level in factory automation lines, water and wastewater treatment skids, power plant auxiliary systems, and oil and gas field instrumentation panels across Oman and the wider GCC, wherever a fixed group of field devices needs simple, reliable Ethernet connectivity without ongoing network management overhead. Its Zone 2 ATEX/IECEx/UKEX/CCC Ex rating additionally allows installation in some classified areas without a separate purge or pressurized enclosure, which matters for panels located near, though not directly within, a Zone 1 hazardous process area common on GCC gas and oil processing sites.

Seven Star LLC supports automation integrators and plant maintenance teams across Muscat, Sohar, and Salalah with genuine SCALANCE hardware, helping specify the right port count and connector mix (copper vs. fiber) for machine-level network segments.

Redundant Power Design

The XC-100’s dual, redundant 12-24 V DC power inputs allow the switch to keep operating on a backup supply if the primary DC rail fails, an important consideration for a machine-level switch whose failure would otherwise disconnect every device wired to it. Plant designers should feed the two inputs from genuinely independent sources (for example separate DC power supplies rather than two terminals off the same rail) to realize the intended redundancy benefit rather than a redundancy in name only, and should size each supply to carry the switch’s full current draw alone in case the other input is lost.

Choosing Port Count and Connector Type

Select the XC108, XC116, or XC124 variant based on the number of devices to connect at the switch’s location, allowing spare ports for planned expansion since adding ports later means installing a second switch rather than upgrading the existing unit. The XC106-2 fiber-uplink variant is the appropriate choice when the switch needs to backhaul traffic over a longer fiber run to a central cabinet, while pure-copper variants suit shorter, in-cabinet or in-cell connections. Because the switch is fanless and unmanaged, it also needs no firmware updates or configuration backups over its service life, reducing the long-term maintenance burden compared with a managed alternative at locations where the added management features would go unused.

Why Seven Star LLC

Seven Star LLC supplies genuine Siemens SCALANCE XC-100 series switches to industrial automation customers across Oman and the wider GCC, confirming the required port count, fiber vs. copper mix, and Zone 2 certification need against your cabinet design before quotation, with delivery to Muscat, Sohar, Salalah, or any other GCC destination.

Related Products

Datasheets & Documents
  • PDF Instruction Manual Siemens SCALANCE XC-100 Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand
Most Siemens automation parts are bought by article number, the string beginning 6ES7, 6AV2 or 6GK5 printed on every module. Founded in 1847 and headquartered in Munich, Siemens builds the SIMATIC controllers, SCALANCE networks and SINAMICS drives that plant engineers meet on almost every site. Seven Star LLC, an independent supplier, lists Siemens PLC and I/O modules, HMI panels, industrial Ethernet switches, drives, protection relays, temperature transmitters and gas analyzer spare parts for projects in Oman and the GCC.

Siemens product families on this page

Controller hardware covers the SIMATIC S7-1200 (CPU 1214C with SM 1223 signal modules) and the S7-1500 (CPU 1515-2 PN), with ET 200SP and ET 200M distributed I/O and their IM 155-6 and IM 153-2 interface modules. Operator panels include the KTP700 Basic and TP700 Comfort. SCALANCE XC208 managed switches handle industrial Ethernet. Drives are represented by the SINAMICS G120C compact inverter and the G120X for pumps and fans. From the power side come the SIPROTEC 7SJ85 feeder protection relay and SIVACON S8 switchboards, and from process instrumentation the SITRANS TH320 head-mounted temperature transmitter.

Where Siemens equipment is used

SIMATIC controllers and ET 200 I/O run packaged units, skids and whole process lines in water treatment, oil and gas, cement, food and manufacturing plants. SINAMICS drives control pumps, fans and conveyors, SCALANCE switches form the control network, and SIPROTEC relays protect medium voltage feeders and motors.

Ordering Siemens parts: what we need

Send the complete article number, the functional status or version printed on the module and, for CPUs, the firmware version your project was written for. For drives add power, supply voltage, filter option and fieldbus version. For SIPROTEC relays the long order number or product code is required, because it fixes the hardware and function package. A nameplate photo answers most of these points at once.

Frequently Asked Questions

Is the SCALANCE XC-100 a managed or unmanaged switch?
It is an unmanaged Ethernet switch, requiring no software configuration, so it can be installed and commissioned as a simple plug-and-play device.
What network speed does the SCALANCE XC-100 support?
It supports Fast Ethernet at 10/100 Mbps across its ports, suitable for connecting PLCs, HMIs, and sensors in an industrial network.
Does the SCALANCE XC-100 need active cooling?
No, it uses a fanless design in a compact enclosure, which improves reliability in dusty or vibration-prone industrial environments by eliminating moving parts.
Can the SCALANCE XC-100 be powered redundantly?
Yes, it supports redundant power supply options, which helps maintain network availability if one power source fails.
What certifications does the SCALANCE XC-100 hold?
It carries certifications including CE, UL, and cULus, supporting its use in industrial installations that require compliance with those standards.