- Vibration Monitoring
- PLC & I/O Cards
- Industrial Communications
- Automation Accessories
- Controllers & Data Acquisition
- AC Drives
- Isolator & Barrier
- Industrial Computers
- Encoders
- Safety Switches & Guard Locking
- Automation Software
- HMI Displays
- Motor Soft Starters
- Servo Drives
- CCTV & Security
- Robotics
- Pneumatic Cylinders
- Machine Vision
Brand: Siemens
16413-1-1 / 16413-1-5 – Siemens APACS MBI/NMI PCI Card
Description
Overview
The Siemens APACS MBI/NMI PCI Card (part numbers 16413-1-1 and 16413-1-5) is a legacy PCI interface card used to connect APACS+ and QUADLOG control systems to host computers. Designed by Moore/Siemens, the board enables communication through the Module Bus Interface (MBI) and Network Module Interface (NMI), giving engineering and monitoring workstations a reliable link into an APACS+/QUADLOG system.
Seven Star LLC supplies genuine and tested Siemens APACS spare parts, including the 16413-1-1/16413-1-5 PCI card, to plants running legacy APACS+/QUADLOG systems across Oman and the GCC, helping maintain critical installed control infrastructure.
Operating Principle
The card installs as a standard PCI board in a host computer and provides two distinct communication paths: the Module Bus Interface for direct communication with APACS+ controller modules, and the Network Module Interface for network-level data exchange with the wider control system. Together, these let an engineering workstation both configure individual controller modules and monitor overall system status from a single PC.
Because the card handles this communication at the hardware level rather than through a generic network adapter, it preserves the deterministic, low-latency link that APACS+/QUADLOG engineering tools expect, which is important for configuration and diagnostic work on safety-related QUADLOG systems.
Engineering Design of the 16413-1-1/16413-1-5
The card is built to the standard PCI form factor for straightforward integration into a Windows-based engineering or monitoring workstation, without requiring specialized computer hardware beyond an available PCI slot. As the underlying APACS+/QUADLOG platform has been discontinued by Siemens, these cards are supplied as tested, functional legacy hardware, keeping installed control systems operable without forcing a premature full-system upgrade.
Because supply of this exact card has become limited as the platform ages, sourcing a properly tested unit matters more than with current-production hardware — a card that tests as functional at time of shipment is the practical assurance available for legacy APACS+/QUADLOG spares of this type.
Key Features
- Module Bus Interface (MBI) connection to APACS+ controller modules
- Network Module Interface (NMI) connection for system-level data exchange
- Standard PCI form factor for Windows-based workstations
- Direct support for engineering, configuration, and diagnostics
- Compatible with APACS+ and QUADLOG safety system integration
- Maintains legacy installed base without forcing a full DCS upgrade
- Tested functional prior to shipment
- Original Siemens/Moore design and manufacture
Industrial Applications
The 16413-1-1/16413-1-5 card is used in engineering workstations for Siemens APACS+ distributed control systems and QUADLOG safety systems, as well as in control room PCs that require MBI/NMI communication for ongoing system maintenance, diagnostics, and expansion work in legacy plants. It remains a necessary component wherever an installed APACS+/QUADLOG system is still in active service.
Across Oman, Muscat, Sohar, Salalah, and the GCC, Seven Star LLC supports plants running legacy Siemens APACS+/QUADLOG systems as a supplier of tested spare parts including this PCI interface card, helping extend the operational life of installed control and safety systems.
Technical Specifications
| Part Numbers | 16413-1-1, 16413-1-5 |
| Type | PCI communication interface card (MBI/NMI) |
| Form Factor | Standard PCI board |
| System Compatibility | Siemens APACS+ / QUADLOG DCS systems |
| Functions | Module Bus Interface, Network Module Interface |
| Condition | Tested functional, pre-owned/surplus |
| Lifecycle | Discontinued by Siemens; supported as legacy hardware |
Request a Quote for 16413-1-1 / 16413-1-5 – Siemens APACS MBI/NMI PCI Card
Contact Seven Star LLC for a quotation, lead time, availability, and technical support on the Siemens APACS MBI/NMI PCI Card and other legacy APACS+/QUADLOG spare parts across Oman and the GCC.
Confirming the Part Number and Revision
APACS+ and QUADLOG workstations were built over many years, and the host PCs, operating systems and engineering software versions vary from site to site. Before ordering, remove the installed card (with the PC shut down and ESD precautions in place) and read the part number and revision from the board label. Note whether the card is a 16413-1-1 or a 16413-1-5, and record:
- the workstation model and its available PCI slots;
- the operating system and the version of the APACS+/QUADLOG engineering software in use;
- whether the card is used for MBI, NMI or both on that station;
- any jumper or address settings on the existing board.
Sharing these details lets the replacement be checked against your setup before shipment, which avoids surprises with legacy hardware.
Installing the Card in a Workstation
Legacy PCI cards are sensitive to the host PC as much as to the card itself. Keep in mind the following points:
- Take a full image backup of the workstation before changing hardware.
- Match any jumper settings to the old card before fitting it.
- Seat the card firmly in a PCI slot; many newer PCs have only PCIe slots and cannot accept it.
- Check that the driver loads correctly and that the engineering tool can see the controllers on the module bus or network.
- Keep the workstation offline from the business network, in line with your OT security policy.
Troubleshooting
If the workstation cannot communicate after a card change, check the driver status and the cable to the module bus or network first. Communication faults on older stations are also often caused by failing PC hardware, such as the motherboard or power supply, rather than the card. Keeping a spare, tested workstation with a known-good card is a practical approach for sites that rely on these systems.
Planning for Legacy APACS+/QUADLOG Systems
Several plants in Oman and the GCC still run APACS+ or QUADLOG systems for control or safety functions. Holding spare interface cards buys time to plan a migration without rushing it after a failure.
Sourcing Through Seven Star LLC
Send Seven Star LLC the part number, revision and workstation details, and we will reply with a quotation, availability and lead time.
Other Models in the Siemens APACS+ / QUADLOG Components Range
Seven Star LLC supplies models from the Siemens APACS+ / QUADLOG Components range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Siemens Moore APACS P/N: 16137-175 | Automation Accessories | View details |
| 16137-151 – Siemens APACS+/QUADLOG M-BUS Side A Cable (4 M) | Controllers & Data Acquisition | View details |
| 16137-222 – Siemens APACS+/QUADLOG M-BUS A Side Cable (2.5 M) | Controllers & Data Acquisition | View details |
| 16137-223 – Siemens APACS+/QUADLOG M-BUS B Side Cable (2.5 M) | Controllers & Data Acquisition | View details |
| 16137-153 – Siemens ModuleBus Cable B-Side (4 M) for APACS+/QUADLOG | Controllers & Data Acquisition | View details |
| 16137-224 – Siemens APACS+/QUADLOG I/O BUS A Side Cable (2.5 M) | Controllers & Data Acquisition | View details |
| 16137-225 – Siemens APACS+/QUADLOG I/O BUS B Cable (2.5 M) | Automation Accessories | View details |
| Siemens APACS Communication Module – ModulNET Interface PC Card (P/N 16413-15, old PN 16267-1) | Industrial Communications | View details |
| 16413-1-1 / 16413-1-5 – Siemens APACS MBI/NMI PCI Card | Industrial Communications | You are viewing this model |
Related Products
- Hirschmann RS30 Industrial Managed Ethernet Switch
- Hirschmann BRS20-12009999 Managed Fast Ethernet Switch (BOBCAT)
- 16137-151 – Siemens APACS+/QUADLOG M-BUS Side A Cable (4 M)
- Blackview BV4800 Pro Rugged Smartphone
- Ethernet-Controller EC86A For IDS 850
- Siemens APACS Communication Module – ModulNET Interface PC Card (P/N 16413-15, old PN 16267-1)
Reviews (0)
How would you rate this product? Cancel reply
About brand
Most Siemens automation parts are bought by article number, the string beginning 6ES7, 6AV2 or 6GK5 printed on every module. Founded in 1847 and headquartered in Munich, Siemens builds the SIMATIC controllers, SCALANCE networks and SINAMICS drives that plant engineers meet on almost every site.
Seven Star LLC, an independent supplier, lists Siemens PLC and I/O modules, HMI panels, industrial Ethernet switches, drives, protection relays, temperature transmitters and gas analyzer spare parts for projects in Oman and the GCC.
Siemens product families on this page
Controller hardware covers the SIMATIC S7-1200 (CPU 1214C with SM 1223 signal modules) and the S7-1500 (CPU 1515-2 PN), with ET 200SP and ET 200M distributed I/O and their IM 155-6 and IM 153-2 interface modules. Operator panels include the KTP700 Basic and TP700 Comfort. SCALANCE XC208 managed switches handle industrial Ethernet. Drives are represented by the SINAMICS G120C compact inverter and the G120X for pumps and fans. From the power side come the SIPROTEC 7SJ85 feeder protection relay and SIVACON S8 switchboards, and from process instrumentation the SITRANS TH320 head-mounted temperature transmitter.
Where Siemens equipment is used
SIMATIC controllers and ET 200 I/O run packaged units, skids and whole process lines in water treatment, oil and gas, cement, food and manufacturing plants. SINAMICS drives control pumps, fans and conveyors, SCALANCE switches form the control network, and SIPROTEC relays protect medium voltage feeders and motors.
Ordering Siemens parts: what we need
Send the complete article number, the functional status or version printed on the module and, for CPUs, the firmware version your project was written for. For drives add power, supply voltage, filter option and fieldbus version. For SIPROTEC relays the long order number or product code is required, because it fixes the hardware and function package. A nameplate photo answers most of these points at once.
Related products
Frequently Asked Questions
It connects a host computer to Siemens APACS+ and QUADLOG control systems via the Module Bus Interface and Network Module Interface.
No, the platform has been discontinued by Siemens; this card is supplied as tested legacy hardware to keep existing installed systems operable.
They are supplied as pre-owned or surplus units that are tested functional prior to shipment.
It enables engineering workstations and control room PCs to configure, monitor, and diagnose APACS+/QUADLOG controllers.
Yes, Seven Star LLC supplies genuine Siemens APACS legacy hardware and spare parts across Oman and the GCC, with technical support.

Reviews