Brand:

Pfannenberg PF 11000 24V IP54 Filterfan, 19 m3/h, 24 V DC

Description

PF 11000 24V IP54 filterfan: compact 24 V DC cabinet ventilation

The PF 11000 24V IP54 is the smallest size of the Pfannenberg filterfan series with a 24 V DC fan. It pushes outside air through a G4 filter mat into a control cabinet, free-flowing 19 m³/h, and needs only 2.4 W. Seven Star LLC supplies the PF 11000 24V IP54 in Oman and the GCC as an independent supplier in Muscat.

The name decodes simply: PF is the filterfan family, 11000 is installation size 1 with a 92 x 92 mm cut-out, 24V is the DC supply and IP54 is the protection class of the front. The manufacturer article number for this exact variant is 11611801055. Because the supply is DC, the fan can run from the same 24 V rail that powers the PLC, which is common in small automation boxes and remote I/O enclosures.

PF 11000 24V IP54 technical specifications

Parameter Specification
Manufacturer / part number Pfannenberg / PF 11000 24V IP54 (article 11611801055)
Rated voltage 24 V DC, tolerance ±10 %
Unimpeded airflow 19 m³/h
Airflow with filter grid 12 m³/h
Number of fans 1
Power consumption 2.4 W
Connection Cable, 2-core, length 310 mm
Pre-fuse gG, 6 A
Protection IP54; NEMA Type 12
Filter Standard filter mat, 88 % efficiency, class G4 (EN 779)
Bearing and life Ball bearing; L10 70,000 h at +40 °C
Ambient temperature -40 to +55 °C
Housing Injection-moulded thermoplastic, UL 94 V0, RAL 7035
Cut-out (H x W) 92 mm x 92 mm
Dimensions (H x W x D) 109 x 109 x 53 mm; installation depth 49 mm
Weight 0.16 kg
UL certificate E489500

How the PF 11000 24V IP54 cools a cabinet

The filterfan is a ventilation device, not a refrigeration device. Its single axial fan draws ambient air through louvres and a filter mat, blows it into the enclosure and lets warmer air leave through a second opening, usually fitted with an exhaust filter. The achievable cooling therefore depends on the gap between the allowed cabinet temperature and the outside air temperature.

With 19 m³/h free air, the PF 11000 24V IP54 suits cabinets with a heat load of a few tens of watts. A quick estimate uses the relation that the airflow in cubic metres per hour is roughly 3.1 times the loss in watts divided by the allowed temperature rise in kelvin. A 15 W load with a 10 K allowed rise needs about 5 m³/h, so the real flow of 12 m³/h with the filter in place leaves a comfortable margin.

Why 24 V DC and a ball bearing matter on the PF 11000 24V IP54

The 230 V sibling PF 11000 230V IP54 uses a sleeve bearing and draws 12 W. The 24 V DC version has a ball bearing with 70,000 hours L10 life at +40 °C and consumes only 2.4 W, so it adds almost no heat of its own and suits cabinets that are already tight on thermal budget. The tiny power draw also makes it easy to run from a battery-backed supply during a mains outage.

Fit in the system and related Pfannenberg parts

Size 1 is the first of the range PF 11000, PF 22000, PF 32000, PF 42500, PF 43000, PF 65000 and the slim PF 67000 SL. An exhaust filter of the same size, from the PFA 10000 line, is normally used on the opposite side. Related options include a thermostat to switch the fan at a set temperature, spare filter mats and a rainhood for outdoor use.

PF 11000 24V IP54 selection and ordering checklist

  • Heat load in watts and the allowed internal cabinet temperature
  • Highest ambient temperature at site, which must stay below the cabinet limit
  • 24 V DC supply available with enough margin for 2.4 W
  • Cut-out of 92 mm and installation depth of at least 49 mm
  • Exhaust filter, thermostat, hygrostat and spare mats needed or not
  • Colour RAL 7035 acceptable
  • Protection class IP54 sufficient for the location

Installing and maintaining the PF 11000 24V IP54

Cut the opening to 92 mm square, fit the filterfan from outside with the fan inside, and connect the two-core cable observing polarity on the DC supply. Place the exhaust opening on the opposite wall and higher up so that warm air can leave by natural convection.

Inspect the filter mat at every service visit and replace it when it is visibly loaded; a clogged mat reduces the airflow and can let the temperature creep up unnoticed. Keep the outlet clear of cables and brackets, and check that the fan turns freely after long periods of storage.

Typical PF 11000 24V IP54 applications in Oman and the GCC

Oil and gas, power, desalination and petrochemical sites in Oman and the GCC share the same enemies of control cabinets: ambient air that is hot for most of the year, fine sand and, on the coast, humid salty air. A small filterfan is the right tool for compact junction boxes, remote terminal units, instrument and analyser enclosures, and PLC boxes where the temperature inside is only a few kelvin above the room temperature. When the outside air reaches the allowed cabinet temperature, ventilation stops being effective and a cooling unit is the better choice.

PF 11000 variants by supply voltage

Model Supply Article
PF 11000 12V IP54 12 V DC 11611851055
PF 11000 24V IP54 24 V DC 11611801055
PF 11000 48V IP54 48 V DC 11611701055
PF 11000 115V IP54 115 V AC 11611151055
PF 11000 230V IP54 230 V AC 11611101055

Information to send with an RFQ for the PF 11000 24V IP54

  • Part number PF 11000 24V IP54 and quantity
  • Accessories: exhaust filter, thermostat, spare filter mats
  • DC supply voltage and cable length needed
  • Heat load and maximum ambient temperature
  • Site conditions such as sand, oil mist or salt air
  • Delivery destination and date

Documents and quotation

A product sheet for the series that includes the PF 11000 24V IP54 is attached on this page; it carries the data tables, dimensions and the article numbers for the other variants of the size.

Seven Star LLC is an independent supplier in Muscat and is not an official channel of the manufacturer. Send the quantity, delivery location and project reference with your request and we will reply with availability, lead time and a formal quotation.

Other Models in the Pf Filterfan Ip54 Range

Seven Star LLC supplies models from the Pf Filterfan Ip54 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Pfannenberg PF 11000 230V IP54 Filterfan, 19-24 m3/hEnclosure Climate ControlView details
Pfannenberg PF 32000 230V IP54 Filterfan, 98-108 m3/hEnclosure Climate ControlView details
Pfannenberg PF 42500 24V IP54 DC Filterfan, 125 m3/hEnclosure Climate ControlView details
Pfannenberg PF 43000 400V IP54 Filterfan, 223-247 m3/hEnclosure Climate ControlView details
Pfannenberg PF 11000 24V IP54 Filterfan, 19 m3/h, 24 V DCEnclosure Climate ControlYou are viewing this model
Pfannenberg PF 22000 230V IP54 Filterfan, 61-70 m3/hEnclosure Climate ControlView details
Pfannenberg PF 43000 230V IP54 Filterfan, 223-247 m3/hEnclosure Climate ControlView details
Datasheets & Documents
  • PDF Datasheet Pfannenberg PF 11000 24V IP54 Product Sheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Pfannenberg is the German maker of thermal management and signalling products for electrical enclosures and industry: filter fans, cooling units, air-to-water heat exchangers, chillers, heaters, sirens and beacons. Otto Pfannenberg, an electrical engineer, founded the company in Hamburg in 1954, and in 1958 he invented the filter fan to stop components in control cabinets from overheating. Pfannenberg is still family-owned and headquartered in Hamburg.

Seven Star LLC is an independent supplier in Muscat. We list Pfannenberg signalling devices and enclosure climate products for panel builders and plant engineers in Oman and the GCC.

Pfannenberg company profile

Founded 1954, Hamburg, Germany
Founder Otto Pfannenberg, electrical engineer
Headquarters Hamburg, Germany; North American headquarters in Lancaster, New York
Ownership Family-owned
Product families PF Filterfans, DTS and DTI cooling units, air-to-water heat exchangers, process chillers, enclosure heaters and thermostats, PA and DS sirens, beacons and combined signalling devices

Milestones

  • 1954: Otto Pfannenberg founds the company in Hamburg.
  • 1958: Pfannenberg invents the filter fan for control cabinets.
  • 1962: The company introduces an industrial flashing light that does not need a bulb change after activation.

Pfannenberg product series

Signalling devices include the PATROL PA X combined flashing sounders from 105 to 122 dB(A), the PYRA flashing light sounder, the PRO 10-Ex sounder for zone 2 and zone 22, and the INTENSE BR 50 modular LED signal tower.

Thermal management covers FLZ enclosure thermostats, twin thermostats, hygrostats and Peltier thermostats, FLH radiant heaters and PFH and FLH-T fan heaters, PF filter fans in several installation sizes up to 785 m3/h and the PTF roof-mounted filter fan, and DTS and DTI cooling units, including the DTI outdoor version.

Where Pfannenberg products are used

Control and drive cabinets on machines and in plant rooms, outdoor enclosures in hot and humid climates, and alarm and evacuation signalling in industrial buildings and process areas. In the Gulf, cabinet cooling and condensation control are the main reasons for specifying Pfannenberg thermal products.

Pfannenberg products we list

Family Examples
Enclosure Climate Control FLH 060 Radiant Enclosure Heater, FLH-T 600 Fan Heater with Integrated, FLZ 510 Enclosure Thermostat, FLZ 541 Twin Thermostat, FLZ 600 Hygrostat for Control Cabinets, FLZ 700 Peltier Unit Thermostat, PFH 650 Compact Fan Heater
Fire & Gas Detectors INTENSE BR 50 Modular LED Signal Tower, PA X 1-05 PATROL Flashing Sounder 105 dB(A), PA X 20-10 PATROL Flashing Sounder 122 dB(A), PA X 5-05 PATROL Flashing Sounder 107 dB(A), PRO 10-Ex Explosion-Proof Sounder 116 dB(A), PY X-MA-05 PYRA Flashing Light Sounder 101
Cooling DTI 8401P Outdoor Cooling Unit, DTS 3061 Cooling Unit, PF 22.000 DC Filterfan, PF 66.000 Filterfan, PTF 60.500 Roof-Mounted Filterfan

Ordering Pfannenberg products: what we need

Send the article number or full designation, such as PA X 1-05 or DTI 8401P. For signalling devices add the supply voltage, lens and housing colour and any required approval such as EN 54-3 or an Ex certificate. For cooling units give the cooling capacity, voltage and frequency, mounting (side or roof, internal or external) and the ambient temperature. For fans and heaters give the installation size, voltage and airflow or heating power.

Facts checked against Pfannenberg's published company history, October 2026.

FAQ

Questions about the Pfannenberg PF 11000 24V IP54 Filterfan, 19 m3/h,

Answers from our engineering team on installation, compatibility and integration.

01What airflow does the PF 11000 24V IP54 deliver?
The unimpeded airflow is 19 m3/h, and 12 m3/h with the filter grid fitted.
02What is its power consumption?
The fan draws 2.4 W from a 24 V DC supply.
03What cut-out size does it need?
A square cut-out of 92 mm by 92 mm with an installation depth of 49 mm.
04How long does the fan last?
The ball bearing has an L10 service life of 70,000 hours at +40 degrees C.
05What protection class applies?