Brand: Pfannenberg
Pfannenberg DTS 3181 460V NEMA 4X Cooling Unit, 1140 W
Description
DTS 3181 460V cooling unit: decoded part number
The DTS 3181 460V is a NEMA 4/4X cooling unit of the 1.1 to 1.2 kW class intended for outdoor and washdown installations. It is the 460 V version of the DTS 3181, and it keeps a sealed enclosure cool with a refrigeration circuit, even where the surrounding air is hot, humid and contaminated.
Decoded: DTS = side mount, 3181 = NEMA 4/4X unit in the 1140 to 1235 W class, 460V = 460 V supply (the order number is 13385436158, SC controller). The NEMA 3R/4 twin is the DTS 3161.
Technical specifications of the DTS 3181 460V
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Pfannenberg / DTS 3181 460V |
| Cooling capacity (EN 14511) | 1140 W at 50 Hz and 1200 W at 60 Hz (A35/A35); 350 W at A35/A50 |
| Supply | 460 V AC, 2-phase / single-phase as listed, 50 / 60 Hz |
| Power consumption (A35/A35) | 1200 W |
| Current consumption | 2 A; starting current 15 A |
| Pre-fuse | T 4 A |
| Airflow (free flow) | Internal 300 m³/h; external 190 m³/h |
| Noise level | Below 70 dB(A) |
| Controller | Standard Controller |
| Refrigerant | R513A, 360 g |
| Ambient temperature (SC) | 0 °C to +55 °C |
| Setpoint range | +25 °C to +45 °C, adjustable |
| Duty cycle | 100 % |
| Protection | IP56; NEMA Type 4 / 4X towards the enclosure |
| Condensate | Integrated evaporation system with safety overflow |
| Dimensions (H x W x D) | 749 mm x 394 mm x 237 mm |
| Housing | Powder-coated housing; galvanised cover |
Values are from the product page for article 13385436158 and the series sheet. The A35/A50 capacity for the 460 V version is 350 W according to the sheet; confirm on the sheet for your supply.
How the DTS 3181 460V works
The unit contains a hermetically sealed refrigerant circuit; the internal air is cooled and dehumidified and the condensate is evaporated in an integrated system so that no drain pipe is necessary. The condenser has 3 mm fin spacing and fully coated heat exchangers and tubing, designed to survive contaminated ambient air.
The unit maintains a UL-tested NEMA 3R/4 or 4/4X seal against the enclosure according to the sheet; the 4/4X version is relevant where hosing down is part of the cleaning routine. It is rated at 100 % duty cycle.
The low ambient version (LAP) of the same unit adds a 900 W heater and thermostat for temperatures below 0 °C. This SC article is for ambient from 0 °C to +55 °C.
Fit in the system and related Pfannenberg parts
This is the middle class of the DTS 3000 family, above the 694 W DTS 3081 and below the 1900 to 2000 W DTS 3281.
- 230 V SC version: article 13385441158; 115 V 60 Hz SC: 13385444158
- LAP versions: 13385436178 (460 V), 13385441178 (230 V), 13385444178 (115 V)
- NEMA 3R/4 DTS 3161 with the same capacity class: for example 13385436355
- The DTS 3185 is a related model with its own sheet
Selection and ordering checklist for the DTS 3181 460V
Before ordering the DTS 3181 460V, settle the following points so that the right variant is quoted:
- Heat load and worst-case ambient; capacity at A35/A50 is much lower than at A35/A35
- Supply voltage: 460 V for this article, 230 V and 115 V versions exist
- SC (0 to +55 °C) or LAP (-40 to +55 °C)
- NEMA 4/4X or 3R/4 housing
- Enclosure depth and available wall area for 749 mm x 394 mm
Installation, commissioning and maintenance of the DTS 3181 460V
Mounting is on the outside of the enclosure with the cut-out shown on the manufacturer drawing. Seal carefully because the NEMA claim depends on the seal. Connect the supply using the plug supplied and the T 4 A protective device.
On start-up verify the temperature setpoint and check that the evaporation system is not flooded after long periods of humid operation.
- Clean the condenser regularly
- Check the seal and fasteners for corrosion
- Inspect the evaporation tray
- Use qualified personnel for the refrigerant circuit
Typical applications in Oman and the GCC
This size is used for outdoor instrument and analyser cabinets, wellhead and pipeline control stations, and loading-arm and jetty cabinets in port areas. With a capacity near 1.1 kW it handles heat loads of drives and PLC racks in sealed enclosures exposed to sun and sand.
As the A35/A50 capacity is considerably lower than the nominal value, sizing for Oman summer conditions needs the performance curve on the sheet, not the headline figure.
Variants related to the DTS 3181 460V
Variants shown by the manufacturer for DTS 3161 / 3181:
| Article | Type | Supply |
|---|---|---|
| 13385436158 | DTS 3181 SC, NEMA 4/4X | 460 V – this variant |
| 13385441158 | DTS 3181 SC | 230 V |
| 13385444158 | DTS 3181 SC | 115 V 60 Hz |
| 13385436178 | DTS 3181 LAP | 460 V |
| 13385436355 | DTS 3161 SC, NEMA 3R/4 | 460 V |
Information to send with an RFQ for the DTS 3181 460V
To quote the DTS 3181 460V quickly, please send:
- Part number DTS 3181 460V and article 13385436158
- Quantity
- Supply voltage and frequency
- Heat load and ambient design temperature
- Enclosure type and required NEMA rating
- Delivery destination and date
Site conditions in Oman for the DTS 3181 460V
Panel cooling in Oman is sized for the worst case, not the average day. Summer shade temperatures in Muscat, Sohar and the interior regularly pass 45 °C, and a cabinet standing in direct sun gains further heat through its walls. When you size the DTS 3181 460V, add the internal losses of drives, power supplies and PLCs to the solar and wall gain, and compare the total with the useful cooling capacity at your real ambient and target cabinet temperature, rather than with a nominal figure stated at milder test conditions.
Coastal sites near Duqm, Salalah or Sur also bring humidity and salt-laden dust. Keep door seals intact, route the condensate drain away from live parts, and plan routine filter and coil cleaning so that the DTS 3181 460V keeps its rated performance through the long summer season.
Documents and quotation
A product sheet for the DTS 3161 and 3181 series is attached on this page, with capacity data, article numbers and accessory table.
For a quotation on the DTS 3181 460V, send the part number or article number, quantity and the delivery destination in Oman or the GCC. Seven Star LLC is an independent supplier based in Muscat and confirms availability and lead time per request.
Datasheets & Documents
- Datasheet Pfannenberg DTS 3181 460V Product Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pfannenberg is the German maker of thermal management and signalling products for electrical enclosures and industry: filter fans, cooling units, air-to-water heat exchangers, chillers, heaters, sirens and beacons. Otto Pfannenberg, an electrical engineer, founded the company in Hamburg in 1954, and in 1958 he invented the filter fan to stop components in control cabinets from overheating. Pfannenberg is still family-owned and headquartered in Hamburg.
Seven Star LLC is an independent supplier in Muscat. We list Pfannenberg signalling devices and enclosure climate products for panel builders and plant engineers in Oman and the GCC.
Pfannenberg company profile
| Founded | 1954, Hamburg, Germany |
|---|---|
| Founder | Otto Pfannenberg, electrical engineer |
| Headquarters | Hamburg, Germany; North American headquarters in Lancaster, New York |
| Ownership | Family-owned |
| Product families | PF Filterfans, DTS and DTI cooling units, air-to-water heat exchangers, process chillers, enclosure heaters and thermostats, PA and DS sirens, beacons and combined signalling devices |
Milestones
- 1954: Otto Pfannenberg founds the company in Hamburg.
- 1958: Pfannenberg invents the filter fan for control cabinets.
- 1962: The company introduces an industrial flashing light that does not need a bulb change after activation.
Pfannenberg product series
Signalling devices include the PATROL PA X combined flashing sounders from 105 to 122 dB(A), the PYRA flashing light sounder, the PRO 10-Ex sounder for zone 2 and zone 22, and the INTENSE BR 50 modular LED signal tower.
Thermal management covers FLZ enclosure thermostats, twin thermostats, hygrostats and Peltier thermostats, FLH radiant heaters and PFH and FLH-T fan heaters, PF filter fans in several installation sizes up to 785 m3/h and the PTF roof-mounted filter fan, and DTS and DTI cooling units, including the DTI outdoor version.
Where Pfannenberg products are used
Control and drive cabinets on machines and in plant rooms, outdoor enclosures in hot and humid climates, and alarm and evacuation signalling in industrial buildings and process areas. In the Gulf, cabinet cooling and condensation control are the main reasons for specifying Pfannenberg thermal products.
Pfannenberg products we list
Ordering Pfannenberg products: what we need
Send the article number or full designation, such as PA X 1-05 or DTI 8401P. For signalling devices add the supply voltage, lens and housing colour and any required approval such as EN 54-3 or an Ex certificate. For cooling units give the cooling capacity, voltage and frequency, mounting (side or roof, internal or external) and the ambient temperature. For fans and heaters give the installation size, voltage and airflow or heating power.
Facts checked against Pfannenberg's published company history, October 2026.
Browse Pfannenberg products by category: Enclosure Climate Control, Fire & Gas Detectors, Cooling.
FAQ
Questions about the Pfannenberg DTS 3181 460V NEMA 4X Cooling Unit,
Answers from our engineering team on installation, compatibility and integration.
01What supply does the DTS 3181 460V need?
The product page lists 460 V AC (2/1~) and the sheet gives a T 4 A pre-fuse for this voltage class. Confirm the phase arrangement of your supply before ordering.
02What capacity does it give?
1140 W at 50 Hz and 1200 W at 60 Hz at A35/A35, falling to 350 W at A35/A50 for this voltage class.
03What are the airflows?
The sheet gives 300 m³/h internal and 190 m³/h external, free flow.
04How is condensate handled?
It has an integrated condensate evaporation system with a safety overflow.
05What are the dimensions?
749 mm x 394 mm x 237 mm, according to the product page.