Pfannenberg DTS 6401 230V Green Series Cooling Unit, 2 kW
Description
DTS 6401 230V SC cooling unit: decoded part number
The DTS 6401 230V SC is a 2000 W side-mount cooling unit from the Pfannenberg Green Series. It cools the air inside a sealed electrical enclosure with a refrigeration circuit and discharges heat to the surrounding air, so it keeps electronics at a set temperature even when the ambient air is warmer than the allowed inside temperature.
The name decodes as: DTS = side mount on the outside of the door or wall, 6401 = Green Series 2 kW model, 230V = 230 V single-phase supply and SC = Standard Controller. The article number is 13889411055 and the colour is RAL 7035.
Technical specifications of the DTS 6401 230V SC
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Pfannenberg / DTS 6401 230V SC |
| Cooling capacity (EN 14511) | 2000 W at A35/A35; 1500 W at A35/A50 |
| Supply | 230 V AC 1~ ±10 %, 50 / 60 Hz |
| Power consumption (A35/A35) | 931 W at 50 Hz; 1126 W at 60 Hz |
| Current consumption | 6.9 A |
| Pre-fuse | gG, 10 A |
| Controller | Standard Controller |
| Refrigerant | R134a, 500 g |
| Ambient temperature | +15 °C to +55 °C |
| Setpoint range | +25 °C to +50 °C, adjustable |
| Protection | IP55 towards the enclosure; IP24 towards the surroundings; NEMA Type 12 |
| Housing and cover | Galvanised sheet steel; cover powder coated (200 °C), RAL 7035 |
| Condensate | Integrated evaporation system with safety overflow |
| Dimensions (H x W x D) | 1547 mm x 485 mm x 278 mm |
Values are from the product page for article 13889411055. The sheet and page describe the internal and external airflow in a different order, so airflow figures are not quoted here; check the sheet for the circuit data.
How the DTS 6401 230V SC works
The unit has a closed refrigerant circuit with a compressor, so cooling does not depend on the outside air temperature being lower than the inside. Warm cabinet air is drawn through the evaporator and returned cooled; the condenser on the other side rejects the heat outside through a separate air path.
The Green Series aims at the lowest energy use for a given cooling capacity and a reduced refrigerant charge. The manufacturer also points to long air paths between intake and exhaust in the enclosure, so that hot spots are not left uncooled, and a service port to read the parameter history with the εCOOL-Plant software.
The SC controller provides a straightforward thermostat function with setpoint, while the MC controller extends this with data and energy-saving functions. The filter is optional and can be added without tools.
Fit in the system and related Pfannenberg parts
This is one of the larger side-mount units in the Green Series, above the 1 kW 6201C and below the X-Series, which reaches higher capacities.
- MC version, same unit: article 13889421055
- Three-phase 400 / 460 V version, SC: article 13889412055
- Partially recessed DTI 6401: article 13899411055 (SC, 230 V)
- Stainless-steel (V2A) version: article 13889411015 for the SC, 230 V variant
Selection and ordering checklist for the DTS 6401 230V SC
Before ordering the DTS 6401 230V SC, settle the following points so that the right variant is quoted:
- Heat load and target cabinet temperature, and the worst-case ambient (capacity is 1500 W at A35/A50)
- Supply: 230 V single-phase with 10 A protection, or a 400 / 460 V variant
- Space for 485 mm x 1547 mm of door or wall surface and 278 mm of projection
- SC or MC controller, stainless steel or painted housing
- Optional filter and external condensate options
Installation, commissioning and maintenance of the DTS 6401 230V SC
The unit is mounted vertically on the door or wall. Plan the bolting and cut-outs before delivery and make sure the wall can carry the weight listed on the sheet. Keep the enclosure sealed; the unit protects at IP55 towards the cabinet only when door seals and cable entries are intact.
At commissioning set the temperature target; the sheet gives a range of +25 °C to +50 °C on the SC version. Avoid setting the target too low, since a very low set-point increases condensation and compressor cycling.
- Clean the condenser and any filter regularly; sandy sites require frequent attention
- Inspect the condensate evaporator and drain path
- Read operating hours and error history through the service port
- Check the refrigerant circuit only through qualified refrigeration personnel
Typical applications in Oman and the GCC
With 2000 W of capacity this unit is a common choice for motor-control centres, drive panels, PLC cabinets and instrument racks at power stations, desalination plants and gas processing sites where heat loads reach a kilowatt or more. In Oman and GCC summers the capacity at +50 °C ambient (1500 W) is the working figure for outdoor kiosks; the +35 °C figure is only valid in conditioned rooms.
Because the unit keeps outside air out of the cabinet, it also protects electronics from dust, humidity and salt that would enter through filterfans on coastal installations.
Variants related to the DTS 6401 230V SC
The table lists variants of the 6401 family shown by the manufacturer.
| Article | Type | Supply |
|---|---|---|
| 13889411055 | DTS side mount, SC | 230 V AC – this variant |
| 13889421055 | DTS side mount, MC | 230 V AC |
| 13889412055 | DTS side mount, SC | 400 / 460 V AC |
| 13889422055 | DTS side mount, MC | 400 / 460 V AC |
| 13899411055 | DTI partially recessed, SC | 230 V AC |
Information to send with an RFQ for the DTS 6401 230V SC
To quote the DTS 6401 230V SC quickly, please send:
- Part number DTS 6401 230V SC and article 13889411055
- Quantity and controller type (SC or MC)
- Supply voltage at the cabinet
- Heat load and ambient design temperature
- Housing finish: painted or stainless steel
- Delivery destination and date
Documents and quotation
A product sheet for the DTI/DTS 6401 Green Series is attached on this page, with capacity data, article numbers, accessories and capacity curves.
For a quotation on the DTS 6401 230V SC, send the part number or article number, quantity and the delivery destination in Oman or the GCC. Seven Star LLC is an independent supplier based in Muscat and confirms availability and lead time per request.
Datasheets & Documents
- Datasheet Pfannenberg DTS 6401 230V SC Product Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pfannenberg is the German maker of thermal management and signalling products for electrical enclosures and industry: filter fans, cooling units, air-to-water heat exchangers, chillers, heaters, sirens and beacons. Otto Pfannenberg, an electrical engineer, founded the company in Hamburg in 1954, and in 1958 he invented the filter fan to stop components in control cabinets from overheating. Pfannenberg is still family-owned and headquartered in Hamburg.
Seven Star LLC is an independent supplier in Muscat. We list Pfannenberg signalling devices and enclosure climate products for panel builders and plant engineers in Oman and the GCC.
Pfannenberg company profile
| Founded | 1954, Hamburg, Germany |
|---|---|
| Founder | Otto Pfannenberg, electrical engineer |
| Headquarters | Hamburg, Germany; North American headquarters in Lancaster, New York |
| Ownership | Family-owned |
| Product families | PF Filterfans, DTS and DTI cooling units, air-to-water heat exchangers, process chillers, enclosure heaters and thermostats, PA and DS sirens, beacons and combined signalling devices |
Milestones
- 1954: Otto Pfannenberg founds the company in Hamburg.
- 1958: Pfannenberg invents the filter fan for control cabinets.
- 1962: The company introduces an industrial flashing light that does not need a bulb change after activation.
Pfannenberg product series
Signalling devices include the PATROL PA X combined flashing sounders from 105 to 122 dB(A), the PYRA flashing light sounder, the PRO 10-Ex sounder for zone 2 and zone 22, and the INTENSE BR 50 modular LED signal tower.
Thermal management covers FLZ enclosure thermostats, twin thermostats, hygrostats and Peltier thermostats, FLH radiant heaters and PFH and FLH-T fan heaters, PF filter fans in several installation sizes up to 785 m3/h and the PTF roof-mounted filter fan, and DTS and DTI cooling units, including the DTI outdoor version.
Where Pfannenberg products are used
Control and drive cabinets on machines and in plant rooms, outdoor enclosures in hot and humid climates, and alarm and evacuation signalling in industrial buildings and process areas. In the Gulf, cabinet cooling and condensation control are the main reasons for specifying Pfannenberg thermal products.
Pfannenberg products we list
Ordering Pfannenberg products: what we need
Send the article number or full designation, such as PA X 1-05 or DTI 8401P. For signalling devices add the supply voltage, lens and housing colour and any required approval such as EN 54-3 or an Ex certificate. For cooling units give the cooling capacity, voltage and frequency, mounting (side or roof, internal or external) and the ambient temperature. For fans and heaters give the installation size, voltage and airflow or heating power.
Facts checked against Pfannenberg's published company history, October 2026.
Browse Pfannenberg products by category: Enclosure Climate Control, Fire & Gas Detectors, Cooling.
FAQ
Questions about the Pfannenberg DTS 6401 230V Green Series Cooling
Answers from our engineering team on installation, compatibility and integration.
01What does the DTS 6401 230V SC offer in cooling capacity?
The sheet states 2000 W at A35/A35 and 1500 W at A35/A50 to EN 14511. Capacity therefore falls by a quarter when ambient rises from +35 °C to +50 °C.
02What is SC?
SC is the Standard Controller. The MC (Multi Controller) version of the same unit offers additional functions and has article 13889421055.
03What are the mounting dimensions?
The product page gives 1547 mm x 485 mm x 278 mm for the DTS side-mount version.
04What power does it draw?
The page lists 931 W at 50 Hz and 1126 W at 60 Hz at A35/A35 with a current of 6.9 A and a gG 10 A pre-fuse.
05Is it a low-refrigerant design?
The Green Series uses significantly less refrigerant than earlier units; this unit contains R134a, 500 g, and is described as UL listed to UL 60335.


















Reviews