Brand: Danfoss
Danfoss 130B1100 VLT PROFIBUS DP MCA 101 Fieldbus Option Card
Description
A PROFIBUS DP-V1 fieldbus card for VLT frequency converters
130B1100 is the Danfoss VLT PROFIBUS DP MCA 101 option, an A-option card that lets a VLT frequency converter communicate with any master that meets the PROFIBUS standard. It supports PROFIBUS DP-V1 and the PROFIdrive frequency converter profile with Danfoss’s company-specific implementation. The card plugs into the option A slot of the drive. The Danfoss Installation Guide MG33C602 states that it covers ordering numbers 130B1100 and 130B1200, and the store lists 130B1100 as a spare part in the interface board options group.
Technical specifications
| Parameter | Specification |
|---|---|
| Danfoss ordering number | 130B1100 |
| Product | VLT PROFIBUS DP MCA 101 (Profibus DP V1) |
| Option position | Option A (interface board) |
| Protocol | PROFIBUS DP-V1, PROFIdrive profile |
| Compatible drives (Installation Guide) | FC 102, FC 103, FC 202, FC 301/302, FCP 106 and FCM 106 |
| Station address range | 0-125 (factory setting 127), set by switches or parameter 9-18 |
| Maximum nodes per segment | 32 field devices; up to 122 active nodes with 3 repeaters |
| Bus cable | Twisted pair, maximum 0.34 mm2 (AWG 22), copper braided screen |
| Termination | Switch on the option; the D-sub 9 adapter has its own termination switch |
| Terminals | 62 (RxD/TxD-P), 63 (RxD/TxD-N), 66 and 67 (5 V DC for external termination) |
| Net weight | 0.413 kg (Danfoss store) |
| Gross weight | 0.451 kg |
| EAN | 5702427150713 |
| Related order number | 130B1200 (listed in the same guide) |
Bus length, speed and addressing
The Installation Guide gives the maximum total bus cable length including drop cables: 1000 m per segment at 9.6 to 187.5 kBaud, 400 m at 500 kBaud, 200 m at 1.5 MBaud and 100 m at 3 to 12 MBaud. A bus segment can carry 32 field devices; a repeater counts as a node in each of the two segments it connects. Set a unique address with the 8-way address switch, or leave all switches on ON and assign the address through parameter 9-18 Node Address. The terminal wiring uses a red wire on terminal 62 and a green wire on terminal 63 for the standard PROFIBUS cable colour code.
Fitting the card and what to check
Mount the option with the connector facing up for top cable entry or facing down, keep at least 200 mm between power, motor and fieldbus cables, and fit the supplied EMC bracket so the cable screen contacts the metal. Items supplied when the option is not factory fitted are the card and connector, an LCP cradle, front covers, stickers, an accessories bag with an EMC bracket and the installation guide. Programming and configuration are described in the separate MCA 101 Programming Guide, and the card can be configured with MCT 10 Set-up Software. Check the drive series and software version before ordering, because the guide names only the VLT drives listed above.
Key features of the MCA 101 card
- PROFIBUS DP-V1 communication with the PROFIdrive profile.
- Fits the option A slot of the supported VLT drive series.
- Station address 0–125, set with switches or by parameter 9-18.
- Built-in bus termination switch, with terminals 66 and 67 providing 5 V DC for external termination.
- Supports baud rates from 9.6 kBaud up to 12 MBaud, depending on bus length.
Cyclic and acyclic data
PROFIBUS DP-V1 adds acyclic services to the standard cyclic exchange. In practice, the PLC uses cyclic data for the control word, speed reference, status word and actual speed, while acyclic access allows parameters to be read or written without interrupting the process data. This is useful for diagnostics, reading fault logs or changing ramp times from the control system. The configuration of process data is done in the drive parameters and in the GSD file loaded into the master engineering tool.
Engineering steps
- Import the Danfoss GSD file for the card into the PLC configuration software.
- Select the PPO type that matches the number of process data words you need.
- Set the same station address on the card as in the master configuration.
- Set the drive parameters for control source and reference so that the fieldbus controls the drive.
- Test the communication and verify control word handling before running the motor.
Cabling practice for reliable communication
Most PROFIBUS faults are caused by wiring rather than by electronics. Use proper PROFIBUS cable, connect the screen at both ends to earth with a large contact area, and keep the bus cable separate from motor cables. Only the first and last devices on each segment should be terminated. In panels with several drives, check the termination switches on every card; a termination accidentally left on in the middle of a segment is a common cause of intermittent errors.
Use in Oman and GCC installations
The card is widely used in water and wastewater pumping, HVAC plant and process lines where VLT drives are connected to a PLC or DCS. In hot plant rooms, keep the drive cooling within the drive manufacturer’s limits, as the option card is cooled by the same air. Spare cards are worth stocking at remote sites, because replacing the card with the same type and setting the same address restores communication without reprogramming the PLC.
What to include in your RFQ
Please state the ordering number 130B1100, the quantity, and the drive series and type code it will be fitted to. If you also need a D-sub 9 adapter or bus connectors, list them separately. Include the delivery location and required date.
Replacing an existing card
Before removing a card, note the address switch settings and termination position and save the drive parameter set. Isolate the drive and wait for the DC link to discharge as stated on the drive label. Fit the new card in the same slot, restore the address and termination, and confirm the bus status before returning the drive to automatic control.
Documents and quotation
The Danfoss PROFIBUS DP MCA 101 Installation Guide is linked on this page. Browse the industrial communications category for related interface modules. Seven Star LLC is an independent supplier in Muscat; please send the drive type code, firmware version and the PROFIBUS master details with your RFQ and confirm that 130B1100 (and not the variant 130B1200) is the card you require.
Datasheets & Documents
- Installation Guide Danfoss VLT PROFIBUS DP MCA 101 Installation Guide MG33C602 (manufacturer) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
FAQ
Questions about the Danfoss 130B1100 VLT PROFIBUS DP MCA 101 Fieldbus
Answers from our engineering team on installation, compatibility and integration.
01What is Danfoss 130B1100?
It is the VLT PROFIBUS DP MCA 101 option card, an interface board for option slot A that adds PROFIBUS DP-V1 to compatible VLT drives.
02Which drives accept the MCA 101?
The Installation Guide names FC 102, FC 103, FC 202, FC 301/302, FCP 106 and FCM 106.
03How is the PROFIBUS address set on the 130B1100?
Use the address switches for 0-125 (factory setting 127), or set all switches ON and use parameter 9-18 Node Address.
04How long can the PROFIBUS cable be?
Up to 1000 m per segment at 9.6-187.5 kBaud, down to 100 m at 3-12 MBaud, per the Installation Guide.
05Is 130B1100 the same as 130B1200?
No. The guide covers both ordering numbers; confirm which variant your installation requires before ordering.