- Automation & ControlView all 2,718 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: AMETEK
AMETEK 7000-720-SE WDG-V Furnace Assembly 240 VAC
Description
AMETEK 7000-720-SE overview
AMETEK 7000-720-SE is the replacement furnace assembly for the Thermox WDG-V analyzer in the 240 VAC version. In the Gulf region 230 to 240 VAC supplies are the norm, so this is the version most users in Oman and the GCC will need when the cell furnace fails. The furnace keeps the zirconia cell at temperature and passes sample gas through the heated block. AMETEK lists it as an assembly, furnace, WDG-V, 240 VAC, and the manual spare parts list gives it its own number apart from the 120 VAC furnace 7000-719-SE.
The Thermox WDG-V is AMETEK Process Instruments’ close-coupled extractive analyzer for excess oxygen in flue gas. The datasheet describes a zirconium oxide sensor, measurement redundancy, continual diagnostic functions and SIL 2 capability for burner management systems, with flue gas temperatures up to 1648 degrees C (3000 degrees F) depending on the probe. It is completely field-serviceable, and the manual lists the spare parts by AMETEK part number.
Key features of 7000-720-SE
- Complete WDG-V furnace assembly for 240 VAC analyzers
- Listed in the WDG-V manual spare parts table with the furnace figure reference
- Distinct from the 120 VAC furnace 7000-719-SE
- Replaced in place with standard tools
- Matches the 230 VAC analyzer power option stated in the WDG-V datasheet
- Used with the standard zirconia cell 7000-568-SE
7000-720-SE technical specifications
| Item | Detail |
|---|---|
| Part number | 7000-720-SE |
| Description | Assembly, furnace, WDG-V, 240 VAC |
| Supply version | 240 VAC |
| 120 VAC equivalent | 7000-719-SE |
| Analyzer power options (datasheet) | 115 VAC or 230 VAC, plus or minus 10 percent, 47 to 63 Hz, 740 VA maximum |
| Used in | Thermox WDG-V, WDG-VC, WDG-VCM analyzers |
| Principle (datasheet) | Zirconium oxide for excess oxygen |
| Output range | 0-1 percent to 0-100 percent O2 |
| Accuracy | Plus or minus 0.75 percent of measured value or plus or minus 0.05 percent, whichever is greater |
| Response | 90 percent of a step change in under 11 seconds with flame arrestors |
| Aspirator air | About 3 SCFH at 3 to 6 psig, instrument air or nitrogen |
| Outputs | Three isolated linear current outputs, five alarms, Modbus RTU, HART option |
| Enclosure | Hinged IP65 (NEMA 4X) stainless steel |
| Power | 115 VAC or 230 VAC, plus or minus 10 percent, 740 VA maximum |
Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 7000-720-SE. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.
Typical applications in oil and gas, utilities, water and manufacturing
Process heaters, steam boilers and thermal oxidizers are the applications named in the datasheet, and the key markets are refining and petrochemical, power and steam generation, and furnaces and boilers. In Oman and across the GCC those applications correspond to refinery heaters, gas processing furnaces, utility boilers and thermal oxidizers on petrochemical and fertilizer sites, where excess oxygen is the primary indicator for burner efficiency and safe combustion.
Where 7000-720-SE is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.
Selection and compatibility notes for 7000-720-SE
Confirm the analyzer version (O2 only, combustibles, or combustibles and methane), the supply voltage of the unit and, if possible, the AMETEK serial number before ordering. The WDG-V manual spare parts table is the reference that ties each number to a version.
Part number 7000-720-SE is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.
Installation and commissioning
Open the analyzer, close the process inlet and outlet isolation valves, and disconnect the cell furnace wires as the manual describes. Remove the thermocouple assembly, cell and flow sensor, loosen the Swagelok nut at the furnace base and the nut below the flow sensor, and remove the old furnace. Install 7000-720-SE, reinstall the thermocouple, flow sensor and cell with a fresh cell o-ring, and reconnect the sensor board wiring. Power up and allow the analyzer to warm up before calibration.
Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 7000-720-SE. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.
Maintenance and service life
Before ordering, run the furnace checks from the manual with power disconnected. A high or open resistance on the furnace circuit points to the heater, while a thermocouple fault is handled by the separate kit 7000-839-TE.
Related products and ordering notes
Reference the cell 7000-568-SE, the metal o-ring 42005JE, the box heater 7000-844-SE for 240 VAC and the thermocouple kit 7000-839-TE.
For a spare parts plan, list 7000-720-SE against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.
Operators in Oman and the Gulf work in high ambient temperatures, dust and humidity, and sites often plan turnarounds months ahead, so confirming the exact number of every spare before the shutdown window is valuable. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer, and we handle enquiries for hard-to-find and legacy numbers directly.
Frequently asked questions about 7000-720-SE
- What is AMETEK 7000-720-SE? It is the replacement furnace assembly for the 240 VAC version of the Thermox WDG-V analyzer according to the AMETEK listing and manual.
- Is 7000-720-SE the same as 7000-719-SE? No. 7000-719-SE is the 120 VAC furnace and 7000-720-SE is the 240 VAC furnace, so match the number to the analyzer supply voltage.
- Which power supplies does the WDG-V support? The datasheet gives 115 VAC or 230 VAC, plus or minus 10 percent at 47 to 63 Hz, with 740 VA maximum, depending on the version.
Documents and quotation
The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 7000-720-SE, send the RFQ with the part number 7000-720-SE, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.
Datasheets & Documents
- Datasheet AMETEK WDG-V Flue Gas Oxygen Analyzer Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK 7000-720-SE WDG-V Furnace Assembly 240 VAC
Answers from our engineering team on installation, compatibility and integration.
01What is AMETEK 7000-720-SE?
It is the replacement furnace assembly for the 240 VAC version of the Thermox WDG-V analyzer according to the AMETEK listing and manual.
02Is 7000-720-SE the same as 7000-719-SE?
No. 7000-719-SE is the 120 VAC furnace and 7000-720-SE is the 240 VAC furnace, so match the number to the analyzer supply voltage.
03Which power supplies does the WDG-V support?
The datasheet gives 115 VAC or 230 VAC, plus or minus 10 percent at 47 to 63 Hz, with 740 VA maximum, depending on the version.
04Do I have to remove the analyzer from the flange for 7000-720-SE?
The manual procedure is performed inside the analyzer after isolating the process, and the datasheet describes the analyzer as completely field-serviceable.
05How do I request a quotation for 7000-720-SE?
Send the part number 7000-720-SE, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.


















Reviews