Brand:

AMETEK 7001-226-TE WDG-V Combustibles Block Kit with Ferrules

Description

AMETEK 7001-226-TE overview

AMETEK 7001-226-TE is the combustibles block kit with nut and ferrules for the Thermox WDG-V combustibles analyzer. The combustibles block is the heated manifold that holds the catalytic combustibles detector in the sample path, and the kit includes the compression nut and ferrules used to seal the sample connections. The manual spare parts list gives this number for the combustibles version and a sister number, 7001-227-TE, for the combustibles and methane block. Buyers need the right block for their version, so the pairing matters.

The Thermox WDG-VC measures excess oxygen and combustibles (CO plus H2) in flue gas, and the WDG-VCM adds methane. The datasheet states that the analyzers are SIL 2 compliant for excess oxygen and for combustibles with the RTD catalytic detector, and capable for use in SIS combustion safety systems. The combustibles range is 0-500 ppm to 0-10,000 ppm with 0-2000 ppm as standard.

Key features of 7001-226-TE

  • Combustibles block with nut and ferrules for WDG-VC
  • Manual lists a different number for the combustibles and methane block (7001-227-TE)
  • Holds the combustibles detector in the heated sample path
  • Block heater replaced separately according to the manual
  • Compression fittings supplied for resealing the connection
  • Photo shows block, nut and ferrule set

7001-226-TE technical specifications

Item Detail
Part number 7001-226-TE
Description Kit, combustibles block with nut and ferrules
Version Combustibles (WDG-VC)
Methane version block 7001-227-TE (manual)
Heater Combustibles block heater replaceable, only on combustibles and methane units
Used in Thermox WDG-VC analyzer
Principle (datasheet) Zirconium oxide for O2, catalytic detectors for combustibles
O2 output range 0-1 percent to 0-100 percent
Combustibles range 0-500 ppm to 0-10,000 ppm, 0-2000 ppm standard
Combustibles accuracy Plus or minus 2 percent of full scale or plus or minus 40 ppm, whichever is greater
Combustibles response 90 percent of a step change in under 25 seconds with flame arrestors
Outputs Three isolated linear current outputs, five alarms, Modbus RTU
Max sample dew point 200 degrees C (392 degrees F)
Enclosure Hinged IP65 (NEMA 4X) stainless steel

Values marked as datasheet come from the AMETEK Process Instruments product data sheet for the analyzer family, and parts information comes from the AMETEK parts listing for 7001-226-TE. Always check the nameplate and serial number of the installed analyzer, because options change from unit to unit.

Typical applications in oil and gas, utilities, water and manufacturing

The datasheet lists process heaters, steam boilers and thermal oxidizers, serving refining and petrochemical, power and steam generation, and furnaces and boilers. In Oman and the GCC the combustibles measurement is valued on fired heaters and boilers where a rise in CO plus H2 signals incomplete combustion and an excess-oxygen measurement alone is not enough for burner management.

Where 7001-226-TE is used on utilities, water or manufacturing sites, the common thread is a measurement that has to stay available between shutdowns. A spare held on the shelf turns a long outage into a short maintenance task.

Selection and compatibility notes for 7001-226-TE

Confirm whether the analyzer is a WDG-VC (combustibles) or WDG-VCM (combustibles and methane), and whether it uses an RTD or hot wire combustibles detector, because the detector type changes the kit, the wiring colours and the main processor board.

Part number 7001-226-TE is an exact orderable number in the AMETEK parts listing. Do not substitute by description alone: neighbouring numbers differ by supply voltage, detector type, or analyzer model, and a part that looks similar can be wrong for the unit. If the nameplate or an old purchase order shows a different number, send it to us and we will help to cross-check against the listing.

Installation and commissioning

Disconnect power, let the analyzer cool and close the process isolation valves. The manual gives the detector and block heater procedures: remove the combustibles detector from its housing (disconnect Cact and Cref, loosen the two 4.0 mm hex screws), and slide out the block heater after loosening its 4.0 mm hex screw. With the block removed, fit the new block using the nut and ferrules supplied in 7001-226-TE and tighten the compression fittings carefully. Refit the detector with a new o-ring and reconnect the wires, leak check and then calibrate for combustibles.

Always follow the manufacturer service manual, site permit-to-work and electrical isolation practice when fitting 7001-226-TE. Wear suitable protective equipment around hot analyzer components, and record the new part number, date and calibration results in the maintenance log.

Maintenance and service life

The manual instructs to use a new o-ring each time the combustibles detector is removed. A blocked or contaminated block shows up as slow combustibles response, so inspect it during planned shutdowns.

Related products and ordering notes

Check the detector kits 7000-815-TE or 7002-426-TE, and the Kalrez o-ring 3000-337-JE for the combustibles and methane detector housing.

For a spare parts plan, list 7001-226-TE against the analyzer tag number, record the serial number of the unit and note the date of the last replacement. A short register of this kind lets the next planner see at a glance whether the item is due, and it makes an RFQ faster because the exact number, quantity and analyzer details are ready to send.

Process plants in Oman and the wider GCC run long between shutdowns, which is why maintenance planners check part numbers early and hold critical spares. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We source against the exact number you give us and confirm availability and lead time before you commit.

Frequently asked questions about 7001-226-TE

  • What is AMETEK 7001-226-TE? It is the combustibles block kit with nut and ferrules for the Thermox WDG-V combustibles analyzer.
  • What block does a combustibles and methane unit use? The manual spare parts table lists 7001-227-TE for the combustibles and methane block, so do not use 7001-226-TE on that version.
  • Is the block heater included in 7001-226-TE? The AMETEK listing describes a block with nut and ferrules. The block heater is covered by a separate replacement procedure in the manual.

Documents and quotation

The manufacturer datasheet for the analyzer family is attached to this page where the file is available, and it gives the performance data quoted above. To request pricing and lead time for AMETEK 7001-226-TE, send the RFQ with the part number 7001-226-TE, the quantity, the analyzer model and serial number if known, and your delivery location in Oman or the GCC. Seven Star LLC will reply with availability.

Datasheets & Documents
  • PDF Datasheet AMETEK WDG-VC Combustion Flue Gas Analyzer Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.

Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.

AMETEK company profile

Established 1930, USA, as American Machine and Metals; later renamed AMETEK
Headquarters Berwyn, Pennsylvania
Structure Two groups: Electronic Instruments (EIG) and Electromechanical (EMG)
Process brands Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex

Milestones

  • 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
  • Early 1960s: The company is renamed AMETEK.
  • 2021: AMETEK acquires Magnetrol.

AMETEK products we list

Product Type Typical use
888, 900, 930 Western Research sulfur recovery analysers Tail gas, air demand and H2S in sulfur pits on Claus units
931, 933, 9900RM/WM UV gas analysers H2S in natural gas and multi-component process streams
5000, 3050-OLV, 5100HD, 5100P Moisture analysers Water content in natural gas and process gases; the 5100 models use TDLAS
241CE II, Chanscope II / Model 13 Dew point analysers and testers Hydrocarbon and water dew point of natural gas
WDG 1200/1210, WDG-V, TM2000 Thermox oxygen analysers Combustion control on heaters and boilers, and trace oxygen
SPOT+, Cyclops L Land pyrometers Non-contact temperature of furnaces, kilns, tubes and hot metal
120HD, Ranarex, Drexelbrook RCT-1210 Portable analysers and level Hydrogen purity in generators, gas specific gravity, RF level measurement

Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.

Where AMETEK instruments are used

In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.

Ordering AMETEK products: what we need

Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.

Facts checked against AMETEK company history, October 2026.

FAQ

Questions about the AMETEK 7001-226-TE WDG-V Combustibles Block Kit

Answers from our engineering team on installation, compatibility and integration.

01What is AMETEK 7001-226-TE?
It is the combustibles block kit with nut and ferrules for the Thermox WDG-V combustibles analyzer.
02What block does a combustibles and methane unit use?
The manual spare parts table lists 7001-227-TE for the combustibles and methane block, so do not use 7001-226-TE on that version.
03Is the block heater included in 7001-226-TE?
The AMETEK listing describes a block with nut and ferrules. The block heater is covered by a separate replacement procedure in the manual.
04Does 7001-226-TE need a new detector o-ring?
The manual says to always use a new o-ring when the combustibles detector has been removed.
05How do I request a quotation for 7001-226-TE?
Send the part number 7001-226-TE, the quantity and your delivery location to Seven Star LLC, and we will respond with availability.