ABB 1SBH137001R1331 NF31E-13 Contactor Relay 3 N.O. + 1 N.C.
Description
ABB 1SBH137001R1331: NF31E contactor relay with a linked N.C. contact
ABB 1SBH137001R1331 is the NF31E-13, a four-contact contactor relay for auxiliary and control circuits. A contactor relay looks like a small contactor but has no power poles; its job is to repeat and multiply control signals, to act as an interposing element between a PLC and a bigger device, or to build interlock logic that has to survive a hostile cabinet. The “31” in the name gives its contacts: three normally open and one normally closed.
The coil with suffix 13 covers 100 to 250 V at 50/60 Hz and DC, so the same relay is valid on a 230 V mains control circuit and on a 110 V DC battery-backed circuit. The datasheet notes that the contactor relay has mechanically linked contacts compliant with Annex L of IEC 60947-5-1 and carries the mechanically linked symbol on the side. That means the N.C. contact and the N.O. contacts cannot be closed together if one contact welds, which allows the N.C. contact to serve as a monitoring contact.
One more point on 1SBH137001R1331: the control coil of every NF and AF device in the family is interchangeable at the type-code level, so the suffix 13 you see here is the same 100-250 V AC/DC code used on the AF09 to AF38 contactors. A panel builder can therefore standardise on a single coil voltage code across contactors and contactor relays.
Core features of 1SBH137001R1331
- Contacts 3 N.O. + 1 N.C., 16 A thermal current each, rated up to 690 V.
- Mechanically linked contacts per IEC 60947-5-1 Annex L.
- Coil 100-250 V 50/60 Hz and DC, electronic interface, built-in surge protection.
- Minimum switching capacity 12 V and 3 mA, for use with electronic inputs.
- Mechanical durability 20 million cycles and up to 6000 cycles per hour.
1SBH137001R1331 data table
| Order code | 1SBH137001R1331 |
|---|---|
| Type | NF31E-13 |
| Contact arrangement | 3 N.O. + 1 N.C. |
| Rated operational voltage Ue | 690 V |
| Thermal current Ith (40 C) | 16 A |
| AC-15 24-127 V / 220-240 V | 6 A / 4 A |
| AC-15 400-440 V / 500-690 V | 3 A / 2 A |
| DC-13 at 24 V / 110 V / 220 V | 6 A / 0.55 A / 0.27 A |
| Short-circuit protection gG | 10 A |
| Icw 1 s / 0.1 s | 100 A / 140 A |
| Minimum switching capacity | 12 V / 3 mA |
| Mechanical durability | 20 million cycles |
| Maximum frequency | 6000 cycles per hour |
| Coil operating limits | 0.85 x Uc min to 1.1 x Uc max (60 C) |
| Terminal capacity | 1-2.5 mm2, M3.5, 1.2 Nm |
| Weight | 0.270 kg |
| UL pilot duty | A600, Q600 |
| Operating temperature | -40 to +70 C |
| Storage temperature | -60 to +80 C |
How 1SBH137001R1331 differs from NF40E and NF22E
The three NF..E relays in this group share the housing and the coil; only the contact mix differs. The NF40E-13 has four N.O. contacts and no linked N.C. contact, the NF22E-13 has two N.O. and two N.C., and NF31E-13 sits between them with three N.O. and one N.C. The N.C.-count also drives accessories: on NF31E-13 up to three add-on N.C. contacts can be fitted in the preferred mounting positions and two in the tilted ones, against four and three on the all-N.O. NF40E. Weight is 0.270 kg for all of them with the 13 coil.
Where the NF31E-13 is used
Typical roles are motor starter control, in which three N.O. contacts handle hold-in, run indication and a PLC feedback while the N.C. contact provides an interlock to the reverse contactor. In oil and gas pump stations a bank of such relays repeats the output of an ESD system into several motor circuits. Power substations use contactor relays as trip-circuit supervision elements, and water plants use them for chlorinator and dosing interlocks. The linked contacts give a diagnostic contact for monitored stop functions.
Compatibility and selection
Auxiliary contact blocks of the CA4 family (1-pole and 4-pole) can be fitted at the front and CAL4-11 blocks at the side, as listed in the datasheet. The NF relay differs from an AF contactor by having contacts rated for control circuits: AC-15 is 6 A at 24-127 V and 4 A at 220-240 V. For power switching above these ratings use an AF contactor. Inrush on 100-250 V coils is about 50 VA, holding about 2.2 VA, which is small enough that a PLC relay output can drive the coil of 1SBH137001R1331 through a single contact. Check the AC-15 figure of the load against the contact data rather than the 16 A thermal rating, because inductive coils of contactors and valves are the usual load.
Mounting and wiring
Mount on 35 mm rail or with two M4 screws. Use conductors of 1 to 2.5 mm2, strip 10 mm, and torque coil and pole terminals to 1.2 Nm with a flat 5.5 mm or Pozidriv 2 driver. Keep unused terminal screws tightened. Operation is possible from -40 to +70 degrees C in free air.
Maintenance
Check the relay if it chatters, which points to a low control voltage, below 85 percent of the minimum coil voltage. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Quick answers about 1SBH137001R1331
What contacts does 1SBH137001R1331 provide? Three normally open and one normally closed contact, each with a 16 A thermal current.
Are the contacts of 1SBH137001R1331 mechanically linked? Yes, the datasheet states mechanically linked contacts according to Annex L of IEC 60947-5-1.
What coil does 1SBH137001R1331 use? A 100 to 250 V coil for 50/60 Hz and DC.
Can 1SBH137001R1331 switch low-level signals? The minimum switching capacity is 12 V and 3 mA, which suits many electronic inputs.
Does 1SBH137001R1331 have power poles? No; it is a contactor relay for auxiliary and control circuits, rated AC-15 and DC-13.
Documents and quotation
The technical datasheet for 1SBH137001R1331 can be downloaded on this page. Send an RFQ with the part number 1SBH137001R1331, the quantity and the delivery destination for a quotation.
Other Models in the Abb Nf Range
Seven Star LLC supplies models from the Abb Nf range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| ABB 1SBH137001R1340 NF40E-13 Contactor Relay 4 N.O. Contacts | Contactors & Overload Relays | View details |
| ABB 1SBH137001R1331 NF31E-13 Contactor Relay 3 N.O. + 1 N.C. | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet ABB 1SBH137001R1331 NF31E-13 Contactor Relay 3 N.O. + 1 N.C. Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB 1SBH137001R1331 NF31E-13 Contactor Relay 3 N.O.
Answers from our engineering team on installation, compatibility and integration.
01What contacts does 1SBH137001R1331 provide?
Three normally open and one normally closed contact, each with a 16 A thermal current.
02Are the contacts of 1SBH137001R1331 mechanically linked?
Yes, the datasheet states mechanically linked contacts according to Annex L of IEC 60947-5-1.
03What coil does 1SBH137001R1331 use?
A 100 to 250 V coil for 50/60 Hz and DC.
04Can 1SBH137001R1331 switch low-level signals?
The minimum switching capacity is 12 V and 3 mA, which suits many electronic inputs.
05Does 1SBH137001R1331 have power poles?
No; it is a contactor relay for auxiliary and control circuits, rated AC-15 and DC-13.