Brand:

ABB MS165-73 Manual Motor Starter 62-73 A

Description

ABB MS165-73 manual motor starter, 62 to 73 A setting range

The ABB MS165-73 is a three-pole manual motor starter, also known as a motor protection circuit breaker, with a thermal release adjustable from 62 to 73 A and a fixed magnetic release at 1022 A. The catalogue rates it for 37 kW at 400 V in category AC-3. It belongs to the MS165 frame, which ABB describes as covering motors up to 45 kW (400 V) / 80 A in a width of 55 mm. The order code for this type is 1SAM451000R1018.

The 73 A type, rated 37 kW at 400 V, handles large pump sets, compressors and ventilation fans. The 62 to 73 A window gives about 15 percent adjustment under the upper limit.

Reading the MS165-73 type code and order code

The letters MS mean manual motor starter with thermal and electromagnetic protection, 165 is the frame and 73 is the upper end of the setting range in amperes. The magnetic-only sister range uses the prefix MO, which has no thermal protection and therefore needs a separate overload relay. The type ABB MS165-73 therefore carries both overload and short-circuit protection in one device.

MS165-73 technical specifications

Parameter Specification
Manufacturer / part number ABB / MS165-73
Order code 1SAM451000R1018
Setting range (thermal release) 62 to 73 A
Rated power AC-3 at 400 V 37 kW
Rated instantaneous short-circuit current setting Ii 1022 A
Service short-circuit breaking capacity Ics at 400 V AC 30 kA
Ultimate short-circuit breaking capacity Icu at 400 V AC 30 kA
Back-up fuse at 400 V not specified in the catalogue
Rated operational voltage Ue 690 V AC / 250 V DC
Rated insulation voltage Ui 1000 V
Rated impulse withstand voltage Uimp 8 kV
Trip class 10
Number of poles 3
Width 55 mm
Weight (1 piece) 1.000 kg
Degree of protection IP20 housing, IP10 main terminals
Ambient temperature, operation -25 to +60 °C compensated; open up to +70 °C
Storage temperature -50 to +80 °C
Mounting DIN rail EN 60715, or M4 screws on a mounting plate (2 Nm)
Main terminals 1 or 2 x 1 to 50 mm² rigid stranded, 1 to 35 mm² flexible, 4.0 Nm
Mechanical / electrical durability 50000 / 20000 cycles

How the MS165-73 protects the motor

Two releases work inside the housing. A thermal release follows the motor current and trips on sustained overload according to trip class 10 behaviour, with ambient compensation so that a hot panel does not cause nuisance trips. A magnetic release answers high currents without delay, which at MS165-73 is fixed at 1022 A. The device also senses the loss of one phase, which protects motors against single-phasing, and the rotary handle includes a disconnect function with a clear switch-position indication and a lockable handle. A separate window shows when the device has tripped on a short circuit.

The catalogue does not list this size in the UL type F combination table that stops at 65 A, so for a contactor-based starter confirm the pairing using the combination tables before ordering.

Selecting the MS165-73 for your motor

At 400 V the catalogue lists 30 kA for both Ics and Icu, and the 440 V value drops to 6 kA service and 8 kA ultimate, so this starter should not be used at 440 V or above on boards with high fault levels without a check. No back-up fuse value is given for this type in the catalogue.

  • Read the motor nameplate current at the actual supply voltage and set the dial to that value.
  • Confirm the motor falls within 62 to 73 A.
  • Compare the Ics value of 30 kA at 400 V with the prospective fault current at the point of installation.
  • Check for the fixed 1022 A magnetic setting against the motor start-up current.
  • Choose accessories from the common MS116 / MS132 / MS165 range.

UL and CSA ratings of the MS165-73

The catalogue also gives motor ratings for North American use. At 220 to 240 V AC the MS165-73 is rated 25 hp at a full load of 68 A, and at 440 to 480 V AC it is rated 50 hp at 65 A. Rated voltage under UL/CSA is 600 V AC. These data help when machinery arrives in the Gulf with a UL-oriented control panel.

Accessories and related ABB parts

The catalogue states that auxiliary contacts, signalling contacts, undervoltage releases, shunt trips and power in-feed blocks are suitable throughout the MS116, MS132 and MS165 range. Nearby types in the same frame are MS165-16, MS165-20, MS165-25, MS165-32, MS165-42, MS165-54, MS165-65, MS165-73 and MS165-80. For a motor above 80 A a different protection device is needed. Contactors of the AF family are used for remote switching; the catalogue lists the UL/CSA combinations with AF contactors by size.

Installation and maintenance

  • Snap onto a 35 mm DIN rail or fix with M4 screws at 2 Nm.
  • Leave 150 mm vertical clearance to other units of the same type; side-by-side mounting needs 0 mm.
  • Strip conductors by 16 mm and tighten terminals to 4.0 Nm with a Pozidriv 2 screwdriver.
  • Set the dial and run a trip test during commissioning; the device should be mechanically operated periodically.
  • Maximum operating altitude is 2000 m; shock resistance is 25 g for 11 ms and vibration resistance is 5 g from 3 to 150 Hz.

Heat, dust and humidity are the main stresses for panels in Oman and the GCC, so place the starter in a ventilated enclosure and keep the derating information in view. The listed ambient range is -25 to +60 °C with compensation. Re-tighten terminals after the first weeks of operation, because thermal cycling can loosen heavy conductors.

Typical applications in Oman and the GCC

Motors of this size drive pumps in desalination and water-treatment plants, fans in district cooling and car-park ventilation, compressors in workshops and conveyors in logistics and industrial plants. In oil and gas facilities and in petrochemical plants these starters are installed inside motor control centres and field panels for auxiliaries. Because the starter combines a disconnect function with the protection of the motor, it reduces the number of components in the panel and shortens the wiring.

Information to send with an RFQ

  • Motor nameplate power, current and supply voltage.
  • Supply frequency and prospective short-circuit current at the board.
  • Required accessories such as auxiliary contacts or a shunt trip.
  • Whether a contactor is to be combined with the starter.
  • Quantity and delivery location in Oman or the GCC.

Documents and quotation

A catalogue extract with the MS165 technical data is attached on this page. Send the part number MS165-73 and the motor data and we will confirm availability and delivery.

Seven Star LLC supplies industrial electrical products in Oman and the GCC and can quote MS165-73 together with matching accessories.

Other Models in the Abb Ms165 Manual Motor Starter Range

Seven Star LLC supplies models from the Abb Ms165 Manual Motor Starter range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
ABB MS165-54 Manual Motor Starter 40-54 AContactors & Overload RelaysView details
ABB MS165-73 Manual Motor Starter 62-73 AContactors & Overload RelaysYou are viewing this model
Datasheets & Documents
  • PDF Catalog ABB MS165-73 Catalogue Extract Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.

ABB company profile

Formed 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50%
ASEA Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators
Brown, Boveri & Cie Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri
Headquarters Zurich, Switzerland; ABB Ltd became the group holding company in 1999
Ownership Public company listed on SIX Swiss Exchange and Nasdaq Stockholm
Brands in the group Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers
Product families Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots

Milestones

  • 1883: ASEA is founded in Västerås, Sweden.
  • 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
  • 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
  • 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
  • 2011 and 2017: Baldor Electric and B&R join ABB.
  • 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.

Choosing an ABB drive

ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.

Where ABB products are used

In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.

ABB products we list

Family Examples
AC drives ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module
Breakers, motor control and protection SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay
Flow measurement ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500
Pressure, temperature and level 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge
Analysers Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210
Control systems and actuators AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000

Ordering ABB products: what we need

Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.

Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.

Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.

FAQ

Questions about the ABB MS165-73 Manual Motor Starter 62-73 A

Answers from our engineering team on installation, compatibility and integration.

01What current range does the MS165-73 cover?
The thermal release of the MS165-73 is adjustable from 62 to 73 A. Set the dial to the motor nameplate current inside that window.
02What motor power is the MS165-73 rated for?
The catalogue lists 37 kW at 400 V in category AC-3. The nameplate current of the motor is what actually decides the dial setting.
03What is the breaking capacity of the MS165-73?
At 400 V AC the catalogue lists Ics 30 kA and Icu 30 kA for this type. Compare these with the prospective fault level at the installation.
04What is the instantaneous trip setting of the MS165-73?
The magnetic release of this type is fixed at 1022 A. Check it against the motor start-up current when commissioning high-inertia loads.
05Does the MS165-73 protect against phase loss?
Yes, the MS165 range is described with phase-loss sensitivity, thermal protection and electromagnetic protection in one device, plus a disconnect function.