Brand:

ABB TF42-35 Thermal Overload Relay 29-35 A

Description

ABB TF42-35 thermal overload relay, 29 to 35 A, trip class 10

The ABB TF42-35 is a three-pole thermal overload relay with a setting range of 29 to 35 A. It is an electromechanical device that protects a motor against overload and phase failure, has trip class 10, and is designed to be fitted directly under ABB AF09, AF12, AF16, AF26, AF30 and AF38 contactors. The ABB product ID is 1SAZ721201R1053 and the EAN is 4013614398162.

The TF42-35 is the top rating of the TF42 range. Its signal contacts, one N.C. trip contact (95-96) and one N.O. signal contact (97-98), integrate with the contactor control circuit, and the relay has temperature compensation, automatic or manual reset, a trip-free mechanism, a STOP function and a trip indication.

What the TF42-35 name and product ID tell you

Element Meaning for TF42-35
TF42 Thermal overload relay family, size 42, for AF09 to AF38 contactors
35 Top of the 29 to 35 A setting range; rated operational current 35 A
1SAZ721201R1053 ABB product ID used for ordering
Trip class 10 Tripping time suited to normal starting motors

Neighbouring TF42 ranges have their own product IDs; for example the TF42-24 (20 to 24 A) is 1SAZ721201R1051. Always order by the full type name.

TF42-35 technical specifications

Parameter Specification
Manufacturer / part number ABB / TF42-35
Product ID / EAN 1SAZ721201R1053 / 4013614398162
Setting range 29 … 35 A
Rated operational current Ie (AC-3) 35 A
Trip class 10
Number of poles / protected poles 3 / 3
Auxiliary contacts 1 N.C. (trip) and 1 N.O. (signal)
Rated operational voltage Main circuit 690 V AC; auxiliary circuit 600 V AC/DC
Rated insulation voltage Ui 690 V
Rated impulse withstand voltage Uimp 6 kV (main and auxiliary circuit)
Auxiliary contact thermal current Ith N.C. 6 A; N.O. 4 A
Auxiliary contact AC-15 N.C.: 3 A at 120 V and 240 V, 0.75 A at 400 V and 500 V. N.O.: 0.75 A at 120 to 500 V
Auxiliary contact DC-13 24 V: 1.25 A; 60 V and 125 V: 0.55 A; 250 V: 0.27 A; 500 V: 0.15 A
Degree of protection / pollution degree IP20 / 3
Power loss per pole at rated conditions 2.1 … 2.8 W
Dimensions (W x H x D) 45 x 88.3 x 70.5 mm
Net weight 0.145 kg
Operating ambient -25 … +60 °C, with compensation; storage -50 … +80 °C
Maximum altitude 2000 m
Shock / vibration 25 g, 11 ms / 5 g, 3 to 150 Hz
Standards IEC/EN 60947-1, 60947-4-1, 60947-5-1; UL 60947-1, 60947-4-1
UL/CSA 35 A, 600 V AC; contact rating B600, Q600 (N.C.), Q600 and D300 (N.O.)

The table follows the ABB product data page for the TF42-35, with the technical datasheet 2CDC106023D0201 as the reference document.

How the TF42-35 protects the motor

A bimetal element in each pole heats with the motor current. When the heating exceeds the setting for long enough, the bimetal bends and trips the mechanism, which opens the N.C. contact in the contactor coil circuit. Because all three poles feed one tripping mechanism, a loss of one phase unbalances the heating and trips the relay faster than a balanced overload would. The TF42-35 is temperature compensated, so ambient swings inside -25 to +60 °C do not shift the trip point significantly.

Trip class 10 means the relay is suited to motors that reach speed within a short time, such as most pumps and fans. For long-start loads such as heavy-inertia fans, check the trip curves in the data sheet or consider a different relay class.

Where the TF42-35 fits

The TF42-35 mounts on AF contactors directly: the AF09, AF12, AF16, AF26, AF30 and AF38 are all listed as suitable. For a 400 V motor of 15 kW or so, the nameplate current of about 29 to 35 A matches the setting range, which pairs with an AF30 or AF38 contactor. Separate mounting kits exist for installing the relay on its own rather than under a contactor.

Adjacent TF42 ranges include TF42-24 (20 to 24 A) and TF42-20 (16 to 20 A), so a motor just below 29 A moves to the lower range instead of being forced to the top end of the 29 to 35 A dial.

Choosing and setting the TF42-35

  • Read the motor nameplate full-load current and set the dial to it; the relay covers 29 to 35 A.
  • Select the lower or higher TF42 range if the nameplate current falls near an edge of the dial.
  • Check the contactor: AF09 to AF38 are listed as suitable bodies.
  • Decide on reset mode: automatic or manual can be selected on the relay.
  • Wire the N.C. trip contact (95-96) into the coil circuit and the N.O. contact (97-98) to an alarm or PLC input.
  • Confirm the auxiliary contact loads against the AC-15 and DC-13 values in the table.

Installation, testing and maintenance of the TF42-35

Clip the relay onto the contactor terminals, tighten the main terminals at 2.5 to 2.7 Nm using a Pozidriv 2 screwdriver and tighten the auxiliary terminals at 1 to 1.5 Nm. Main conductors take 2.5 to 10 mm² rigid with a stripping length of 12 mm; auxiliary conductors take 0.75 to 4 mm² rigid with a 9 mm strip. UL/CSA main conductors are 14 to 6 AWG.

After wiring, set the dial, press the TEST function to confirm the contact changeover, and use the RESET button to restore. At periodic inspections check terminal tightness, the dial position against the motor nameplate and any discolouration from heat. The mounting position can be position 1 to 5 as shown in the data sheet.

Approvals listed for the TF42-35

The ABB product data page for the TF42-35 lists these certificate documents: ABS, ATEX, BV, CB, CCC, cUL, cUR, DNV GL, EAC, GL, GOST, LR, RINA, RMRS and UL, plus the CE declaration of conformity and RoHS information. Marine society certificates are listed, which is useful for offshore and shipbuilding projects. Check the certificate scope for your project, particularly ATEX, before relying on it.

The product complies with the RoHS directive 2011/65/EU as stated on the data page.

Typical uses of the TF42-35 in Oman and the GCC

The TF42-35 protects mid-size motors such as cooling water pumps, booster pumps, ventilation fans and compressors on desalination, oil and gas, power and industrial sites. In hot panel rooms, use the temperature compensation to your advantage, but avoid mounting the relay next to heat sources. Dust-laden sites call for sealed enclosures because the relay itself is IP20.

Upgrade projects often need overload relays replaced one for one, so record the dial setting and the contactor type before removing the old one.

RFQ details for the TF42-35

  • Type TF42-35 (1SAZ721201R1053) and quantity.
  • Contactor type that it will be fitted under, or if a separate mounting kit is required.
  • Motor nameplate current and voltage.
  • Reset mode and wiring for trip contact.
  • Project standard (IEC, UL/CSA, marine).

Documents and quotation

A data page for the TF42-35 is attached on this page, covering the technical parameters, dimensions and the certificate list.

Seven Star LLC supplies ABB low-voltage control gear in Oman and the GCC. Send us the part number TF42-35 and your quantity, and we will confirm availability and a quotation.

Datasheets & Documents
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.

ABB company profile

Formed 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50%
ASEA Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators
Brown, Boveri & Cie Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri
Headquarters Zurich, Switzerland; ABB Ltd became the group holding company in 1999
Ownership Public company listed on SIX Swiss Exchange and Nasdaq Stockholm
Brands in the group Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers
Product families Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots

Milestones

  • 1883: ASEA is founded in Västerås, Sweden.
  • 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
  • 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
  • 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
  • 2011 and 2017: Baldor Electric and B&R join ABB.
  • 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.

Choosing an ABB drive

ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.

Where ABB products are used

In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.

ABB products we list

Family Examples
AC drives ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module
Breakers, motor control and protection SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay
Flow measurement ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500
Pressure, temperature and level 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge
Analysers Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210
Control systems and actuators AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000

Ordering ABB products: what we need

Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.

Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.

Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.

FAQ

Questions about the ABB TF42-35 Thermal Overload Relay 29-35 A

Answers from our engineering team on installation, compatibility and integration.

01What current range does the TF42-35 cover?
The TF42-35 has a setting range of 29 to 35 A, with a rated operational current of 35 A in AC-3. The dial is set to the motor nameplate current inside this range.
02Which contactors can the TF42-35 be fitted to?
ABB lists the AF09, AF12, AF16, AF26, AF30 and AF38 contactors as suitable. The relay mounts directly on them, and separate mounting kits exist for stand-alone installation.
03What trip class and contacts does the TF42-35 have?
It is trip class 10 with one N.C. contact for tripping (95-96) and one N.O. signal contact (97-98). Reset can be automatic or manual, and the relay has a STOP function and trip indicator.
04What are the dimensions and weight of the TF42-35?
The net dimensions are 45 mm wide, 88.3 mm high and 70.5 mm deep, and the net weight is 0.145 kg.
05What ambient temperature is allowed for the TF42-35?
Operation is rated from minus 25 to plus 60 degrees C with temperature compensation, and storage from minus 50 to plus 80 degrees C. The maximum operating altitude is 2000 m.