Brand:

Hydac ETS 3228-5-100-000 Two-Output Electronic Temperature Switch

Description

ETS 3228-5-100-000 is the most complete version of the Hydac ETS 3200 tank temperature switch: two PNP switching outputs and one analog output on a 5-pole M12x1 connector, with a 100 mm probe. The code explains it: 8 selects the 5-pole connector and 5 selects two switching outputs plus analog output. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.

Why choose ETS 3228-5-100-000

With two switching outputs, one unit can give a warning and a trip at different temperatures, or drive a heater and a cooler with separate set points. The analog output (selectable 4 to 20 mA or 0 to 10 V) reports the same temperature to a controller. All outputs refer to the range of minus 25 to plus 100 degC. Switch points can be moved in 0.5 degC steps and each hysteresis can be set from 1.0 to 123.5 degC.

The current budget needs attention: total consumption can reach 2.455 A when both outputs are fully loaded, while the instrument itself draws 35 mA with inactive outputs and 55 mA with the analog output active. A 24 V supply with 3 A headroom covers the worst case. Protection against reverse polarity, excess voltage, override and short circuit is built in, as the datasheet note states, which makes commissioning forgiving; still, double-check pins 4 and 5 before powering the loads of ETS 3228-5-100-000.

Features

  • Two PNP outputs, each 1.2 A maximum.
  • Selectable analog output, 4 to 20 mA or 0 to 10 V.
  • Window function with separate lower and upper limits.
  • Display rotates in two planes.
  • Supply 18 to 35 V DC with analog output.
  • Weight about 150 g.

Technical table for ETS 3228-5-100-000

Parameter Value
Model code ETS 3228-5-100-000
Material number (catalog) 909621
Type Electronic temperature switch with 4-digit display, tank installation
Measuring range -13 to 212 degF (-25 to 100 degC)
Probe length 100 mm (3.94 in)
Pressure resistance 725 psi
Process connection G1/2 A DIN 3852, male; torque 33 lb-ft (45 N·m)
Wetted parts Stainless steel connection; FKM seal
Switching outputs 2 PNP switching outputs + 1 analog output
Switching current 1.2 A maximum per output, PNP
Switch point range -23 to 100 degC (-9 to 212 degF), increment 0.5 degC (1 degF)
Hysteresis range 1.0 to 123.5 degC (2 to 222 degF)
Window function lower -23 to 97.5 degC, upper -22 to 98.5 degC
Delay times 0.00 to 99.99 s, on and off
Accuracy (display, analog) 2.0 degF (1.0 degC) or less
Rise time to DIN EN 60751 t50: 8 s; t90: 15 s
Electrical connection Male M12x1, 5-pole
Pins 1 +UB, 2 analog, 3 0 V, 4 SP 1, 5 SP 2
Supply voltage 18 to 35 V DC with analog output
Display 4-digit red LED, 7-segment, digit height 7 mm
Ambient temperature -13 to 176 degF (-13 to 140 degF per UL spec.)
Fluid temperature -40 to 212 degF / -13 to 212 degF with FPM seal
Protection class IP 67
Vibration / shock 10 g / 50 g (11 ms)
Weight about 150 g
Approvals CE (EN 61000-6-1/2/3/4); cULus E318391

Typical uses

Examples include oil temperature control on a hydraulic unit (fan on at one point, alarm at another), gearbox lubrication and process tanks with a heater. In GCC plants the second output can feed a hard-wired shutdown while the analog value goes to the DCS. ETS 3228-5-100-000 is for non-hazardous installations.

How ETS 3228-5-100-000 differs from the ETS 3226 variants

ETS 3226-3-100-000 has one switching output plus analog output on a 4-pole connector. ETS 3226-2-250-000 has two switching outputs without analog on a 4-pole connector and a 250 mm probe. The 3228-5 gives you everything on a 5-pole plug, which is why a 4-pole cable will not fit. The probe length of 100 mm is the shortest of the tank probes.

Selection

Check that your cable has five conductors. For fully independent limits, set both switching directions as needed. If a hazardous area is involved, look at a different approved product instead of ETS 3228-5-100-000.

Installation

Fit the G1/2 A thread with the O-ring, tighten to 45 N·m, turn the display to the readable position and connect all five conductors. Then program SP 1 and SP 2, window or point function and the analog range. Test with a heated reference bath if possible.

Maintenance

Review both set points and the analog scaling at the yearly maintenance round, and confirm the analog output against a calibrated reference thermometer in a stirred bath. Keep the probe free of deposits and the connector seal clean to maintain IP 67 on ETS 3228-5-100-000.

Archive the programmed values and the material number 909621 together with the loop record. When a spare is fitted, the technician can restore the settings from that sheet in a few minutes.

Selection Notes for the Hydac ETS 3228-5-100-000

When comparing the Hydac ETS 3228-5-100-000 with alternatives, start from the duty it must perform: the measured or controlled variable, the range and accuracy you need, the environment at the mounting point and the interface to your control system. Check the electrical and mechanical connections against the installed equipment, and confirm any hazardous-area or ingress-protection requirements for the location. If any point is unclear, send a photo of the nameplate and a short description of the application, and we will compare it with the Hydac temperature transmitters range and confirm the correct order code before you commit.

Frequently asked questions about ETS 3228-5-100-000

Why does ETS 3228-5-100-000 use a 5-pole connector? Because it carries two switching outputs and an analog output; the 4-pole M12 only supports models with output code 2 or 3.

What are the pin functions? Pin 1 +UB, pin 2 analog output, pin 3 0 V, pin 4 switching output 1, pin 5 switching output 2.

What temperature range does it measure? -25 to 100 degC (-13 to 212 degF).

What supply voltage is needed? 18 to 35 V DC because the analog output is present.

How do I request it? Send an RFQ with ETS 3228-5-100-000, quantity and delivery site to Seven Star LLC.

Documents and quotation

The datasheet of ETS 3228-5-100-000 is on this page. Send an RFQ with ETS 3228-5-100-000, quantity and delivery location for availability.

Datasheets & Documents
  • PDF Datasheet Hydac ETS 3228-5-100-000 Two-Output Electronic Temperature Switch Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

HYDAC is the German hydraulics group known for hydraulic filters, accumulators and electronic pressure and temperature sensors. It was founded in 1963 in Sulzbach, Saarland, by Werner Dieter and Otmar Schön. The name comes from "hydraulic accumulator", the first product it made under licence. It is still a family company headquartered in Sulzbach.

Seven Star LLC is an independent supplier in Muscat. We list HYDAC filters, filter elements, accumulators, pressure transmitters and switches, and supply them for hydraulic power units, turbines, compressors and mobile machines in Oman and the GCC.

HYDAC at a glance

Established 1963, Sulzbach, Saarland, Germany
Name From "hydraulic accumulator", the first product line
Ownership Family-owned; around 50 international subsidiaries
Product families Hydraulic and lube oil filters, breathers and dryers, bladder and piston accumulators, electronic pressure, temperature and level sensors and switches, coolers, valves and fluid condition monitoring

HYDAC products we list

Family Models Typical use
Pressure filters DF/DFF, DFN, DFDK change-over, HFM, MDF, MFM, FMND Protect servo and proportional valves downstream of the pump
Low-pressure, return and suction filters LF/LFF, LPF, NF, RFL, RFLD, FLND, RFM, RFN, SF, MF/MFD, MFX Return line, lube oil, turbine oil and suction filtration
Breathers and indicators BF, ELF, BDE dryer, VD clogging indicator Keep dust and moisture out of the tank and show when an element needs changing
Accumulators SB330 bladder accumulator Energy storage, pulsation damping and emergency actuation
Pressure transmitters HDA 4445, HDA 4745, HDA 4844, HDA 4345, HDA 4145, HDA 44Z6, HDA 4746 safety, HDA 4748, HDA 7476, HPT 1448S, HPT 506 DP Pressure measurement in hydraulic and process systems
Pressure, temperature and level switches EDS 3400, EDS 3316, EDS 3146, EDS 34Z6, EDS 4348, EDS 824 IO-Link, EDS 8446, EDS 1791, ETS 1700, ETS 3226, ETS 3866, ENS 3116 Local display plus switching outputs for alarms and interlocks

Most hydraulic failures start with dirty or wet oil. That is why a system has filters at several points: a pressure filter in front of sensitive valves, a return filter that cleans what comes back to the tank, and a breather that stops dust and humidity entering as the oil level moves. The filter element's rating (for example 3, 10 or 25 µm) and its material decide what cleanliness class the oil reaches. On HYDAC sensors, the type code also sets the pressure range, the output and the connector. For example, HDA 4445-A-400-000 is a 4-20 mA transmitter for 0-400 bar.

Where HYDAC products are used

In Oman and the GCC, HYDAC filters, accumulators and sensors are used on turbine and compressor lube oil systems, hydraulic power units, offshore and marine hydraulics, cranes, presses, steel and aluminium plants, and construction and mobile machines.

Ordering HYDAC products: what we need

Send the full HYDAC type code or part number from the label. For filter elements, the element code on the end cap (for example 0160 D 010 BN4HC) gives the size, filter type, micron rating and material. For accumulators, send the volume, pressure rating and connection. For sensors, send the pressure range, output signal and connector.

Facts checked against HYDAC company information, October 2026.

FAQ

Questions about the Hydac ETS 3228-5-100-000 Two-Output Electronic

Answers from our engineering team on installation, compatibility and integration.

01Why does ETS 3228-5-100-000 use a 5-pole connector?
Because it carries two switching outputs and an analog output; the 4-pole M12 only supports models with output code 2 or 3.
02What are the pin functions?
Pin 1 +UB, pin 2 analog output, pin 3 0 V, pin 4 switching output 1, pin 5 switching output 2.
03What temperature range does it measure?
It measures from minus 25 to plus 100 degC, which is minus 13 to plus 212 degF.
04What supply voltage is needed?
18 to 35 V DC because the analog output is present.
05How do I request it?
Send an RFQ with ETS 3228-5-100-000, quantity and delivery site to Seven Star LLC.