Brand:

Yokogawa YTA70 Head Mount HART Temperature Transmitter

Description

Yokogawa YTA70 Head Mount HART Temperature Transmitter: overview

The Yokogawa YTA70 is a head mount temperature transmitter with HART communication. It fits the standard DIN form B head and converts thermocouple, RTD, ohm or millivolt signals into a two-wire 4 to 20 mA signal that can also be configured and read digitally.

Seven Star LLC lists the Yokogawa YTA70 for engineers, maintenance planners and procurement teams in Oman and across the GCC who need to replace an installed unit, extend a loop or specify a new instrument for an oil and gas, utility, water or manufacturing project. The page below summarizes the key facts from the manufacturer datasheet so that a first technical review can be done before the full document is opened.

Key features of the YTA70

  • YTA70 converts thermocouple, RTD, ohm or millivolt inputs into a two-wire 4 to 20 mA signal.
  • Input and output are isolated to 1500 V AC.
  • Programmable response time of 1 to 60 seconds to smooth noisy sensors.
  • Cold junction compensation accuracy of plus or minus 1 C for thermocouple inputs.
  • Polycarbonate enclosure with M3 screw terminals for DIN form B head mounting.
  • EMC conformity to EN 61326-1 Class A and compliance with the EU RoHS directive.

YTA70 technical specifications

The input table covers thermocouples B, E, J, K, N, R, S, T, L, U, Lr, W3 and W5, Pt100 and Ni100 RTDs, and mV and ohm inputs. For Pt100, the range is -200 to 850 C with a minimum span of 10 C and an accuracy of plus or minus 0.1% of span or 0.1 C, whichever is greater. HART revision 5 or 7 is selected when ordering.

HART 7 features long tags up to 32 characters, enhanced burst mode, event notification and command aggregation.

RTD lead wire resistance is limited to 5 ohm per wire, and up to 50 ohm per wire can be set with reduced measurement accuracy.

The table lists the main values stated in the datasheet for this model. Values depend on the selected capsule, wetted material and options, so always confirm the final model code with the datasheet before ordering.

Parameter Value
Type Head mount temperature transmitter, DIN form B, with HART
Inputs Thermocouples, 2-, 3- and 4-wire RTDs, ohms and DC millivolts
Output Two-wire 4 to 20 mA DC with HART 5 or HART 7 (selectable)
Supply voltage 8 to 35 V DC (8 to 30 V DC intrinsically safe); 13.8 to 35 V DC for digital communication
Load resistance 0 to (E-8)/0.0236 ohm; 250 to 600 ohm for communication
Pt100 range and minimum span -200 to 850 C, minimum span 10 C
Pt100 accuracy Plus or minus 0.1% of span or 0.1 C, whichever is greater
Cold junction compensation accuracy Plus or minus 1 C (thermocouples)
Sensor burnout High or low per NAMUR NE43, or a value within 3.5 to 23 mA
Response time 1 to 60 seconds, programmable
Isolation Input and output isolated to 1500 V AC
Ambient temperature -40 to 85 C
Ambient humidity 0 to 95% RH, non-condensing
Enclosure Polycarbonate, red case; M3 screw terminals
Weight 50 g (0.11 lb)

Typical applications in Oman and the GCC

  • Oil and gas. Compressor and pump bearings, heater outlets and process lines on oil and gas sites use the YTA70 to turn a raw RTD or thermocouple into a stable 4 to 20 mA signal: temperature measurement on heat exchangers, process pipes, reactors, furnaces and turbine auxiliaries where the sensor sits in a connection head.
  • Utilities and power. Power and utility plants fit the YTA70 on cooling water, lube-oil, steam and exhaust points, where the transmitter near the sensor reduces noise on long cable runs.
  • Water and desalination. Desalination units and water treatment plants measure feed, brine and product temperature with RTDs, and the YTA70 gives the control system a clean signal from each point.
  • Manufacturing and process. General manufacturing, petrochemical and food plants use the YTA70 on reactors, dryers, ovens and heat exchangers, with sensor burnout detection helping the maintenance team find broken sensors.

Selection and compatibility notes

Select the YTA70 by sensor type and measuring span. Pt100 RTDs are listed from -200 to 850 C, and the input table also covers many thermocouple types. Narrow spans improve resolution but never below the minimum span in the table, and the stated accuracy is the greater of a percentage of span and a fixed value in degrees.

Check the power supply and loop load. The datasheet gives the load resistance formula as a function of supply voltage, so a long cable or an indicator in the loop must be included in the calculation. Sensor burnout direction should be agreed with the control system so that a broken sensor produces a safe, recognizable signal.

For hazardous areas, review the intrinsically safe approval option codes listed in the datasheet and compare the entity parameters with the barrier or isolator that will be used.

Installation and commissioning of the YTA70

Wire the YTA70 to the sensor terminals following the sensor type diagram, set the input type and span with the configuration tool, and then check the loop with a sensor simulator or a decade box. Keep the sensor leads away from power cables, and use shielded cable where the plant has strong electrical noise.

Record the sensor type, range and burnout direction in the commissioning record for the YTA70, and keep the configuration file so that a replacement unit can be set up quickly.

Maintenance and calibration

Maintenance of the YTA70 is limited to periodic loop checks. Verify the output at several points with a calibrator, inspect terminals for corrosion, and check the sensor for drift or damage. If the transmitter fails, replace it and reload the saved configuration, which keeps downtime very short.

Good practice for temperature loops also includes storing the sensor calibration certificate with the loop record and checking the cable shield and gland sealing at each shutdown. Moisture ingress at the connection head is a common cause of drifting readings in hot and humid coastal sites, and a quick inspection prevents most such faults.

Related products and ordering notes for the YTA70

Other Yokogawa models in the same product area include YTA70P, YTA50, YTA610 and YTA710, which may suit neighboring points on the same plant. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Product names and model codes are used only to identify compatible equipment.

When you ask for a quotation, state the exact model code, the measuring range, the output type, any hazardous area approval and the quantity. A complete code lets us confirm that the unit matches the installed unit or the project specification, and it avoids delays caused by option mismatches.

Frequently asked questions in short

What is the Yokogawa this model? The Yokogawa this model is a head mount HART temperature transmitter. The this model is a head mount temperature transmitter with HART communication. What measuring ranges does the this model cover? Datasheet values for the YTA70: Thermocouples, 2-, 3- and 4-wire RTDs, ohms and DC millivolts. What accuracy and output does the YTA70 provide? For the YTA70 the datasheet gives plus or minus 0.1% of span or 0.1 c, whichever is greater. Output and communication: Two-wire 4 to 20 mA DC with HART 5 or HART 7 (selectable).

Documents and quotation

The manufacturer datasheet for the YTA70 is attached to this page and gives the complete model and suffix codes, dimensions and options. To receive a quotation, send the RFQ with the part number YTA70, the quantity and your required range and approvals, and the Seven Star LLC team will reply with availability and delivery information for Oman and the GCC.

Other Models in the Yokogawa Temp_head Range

Seven Star LLC supplies models from the Yokogawa Temp_head range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Yokogawa YTA50 Head Mount Temperature TransmitterTemperature TransmittersView details
Yokogawa YTA70 Head Mount HART Temperature TransmitterTemperature TransmittersYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Yokogawa YTA70 Head Mount HART Temperature Transmitter Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa YTA70 Head Mount HART Temperature

Answers from our engineering team on installation, compatibility and integration.

01What is the Yokogawa YTA70?
The Yokogawa YTA70 is a head mount HART temperature transmitter. The YTA70 is a head mount temperature transmitter with HART communication.
02What measuring ranges does the YTA70 cover?
Datasheet values for the YTA70: Thermocouples, 2-, 3- and 4-wire RTDs, ohms and DC millivolts.
03What accuracy and output does the YTA70 provide?
For the YTA70 the datasheet gives plus or minus 0.1% of span or 0.1 c, whichever is greater. Output and communication: Two-wire 4 to 20 mA DC with HART 5 or HART 7 (selectable).
04How is the YTA70 configured?
The YTA70 is configured for sensor type, range, damping and burnout direction. See the datasheet for the details of the input table and the supply and load limits.
05How can I request a quotation for the YTA70 in Oman?
Send an RFQ with the part number YTA70, quantity, range, output and approvals through the inquiry form. Seven Star LLC replies with availability and delivery for Oman and the GCC, and the datasheet is on the product page.