Brand: Yokogawa
Yokogawa S9129FA Backup Battery Pack
Description
Overview
The Yokogawa S9129FA is a rechargeable nickel-metal hydride (Ni-MH) backup battery pack used in Yokogawa distributed control systems, mainly the CENTUM CS 1000 and CENTUM CS 3000 platforms. When main power is lost, it keeps the module’s configuration memory and real-time clock powered. This preserves configuration data and timekeeping, so the system can resume correctly once power returns without having to be reconfigured.
The S9129FA is a legacy Yokogawa spare part. Distributors publish different nominal voltage and capacity figures for it, and no current first-party Yokogawa datasheet was found to settle them. For that reason, the electrical rating is not stated here and must be confirmed against the installed pack or the module documentation before ordering.
Key Features
- Rechargeable Ni-MH backup battery pack
- Keeps configuration memory and real-time clock powered during power interruptions
- Used in Yokogawa CENTUM CS 1000 and CENTUM CS 3000 DCS hardware
- Replaceable maintenance item for planned preventive replacement
- Identified by Yokogawa part number S9129FA for spare-part ordering
Technical Specifications
| Parameter | Value |
|---|---|
| Part number | S9129FA |
| Manufacturer | Yokogawa Electric Corporation |
| Product type | Backup battery pack |
| Chemistry | Nickel-metal hydride (Ni-MH), rechargeable |
| Used in | Yokogawa CENTUM CS 1000 / CS 3000 DCS |
| Function | Backup for memory and real-time clock |
Applications
- Scheduled replacement of backup batteries in legacy CENTUM CS 1000 and CS 3000 installations
- Critical spares holding for DCS systems in oil and gas, petrochemical and power generation plants
- Replacing a pack after a low-battery alarm, to avoid losing configuration data during a later power outage
Standard practice for critical control systems is to replace backup batteries on a planned maintenance interval rather than waiting for an alarm. A depleted battery combined with an unplanned power interruption can lead to loss of stored configuration.
Yokogawa S9129FA Storage and Handling Notes
The Yokogawa safety data sheet that covers S9129FA groups it with other Yokogawa battery part numbers under nickel metal hydride / nickel cadmium batteries. The pack is built from sealed cylindrical cells in metal cases fitted with a gas release vent, and in normal use there is no leakage or ignition hazard.
For spares handling, the data sheet asks for storage in a cool, dry, ventilated place away from oxidising agents, acids, alkalis and heat sources. The cells are non-flammable but can vent or burst in a fire. For shipment the batteries fall under UN3028 but are exempt from dangerous goods regulations provided they are securely packed and protected against short circuit. Used packs should be recycled where possible or disposed of under local rules.
Why Seven Star LLC
Seven Star LLC supplies Yokogawa DCS spare parts to process plants across Oman and the GCC. Before quoting, we check the part number, the module the pack fits into, and the connector arrangement against your installed hardware, because aftermarket packs can differ in connector orientation and lead length.
Also available: Yokogawa EJX910A Multivariable Transmitter
Request a Quote for Yokogawa S9129FA Backup Battery Pack
Submit a formal inquiry through our RFQ page with the part number S9129FA, the quantity, the CENTUM system and module the pack is installed in, and the voltage and capacity printed on your existing pack label. Our team will confirm the correct battery pack and send a formal quotation.
How the Yokogawa S9129FA Backup Battery Works
In a DCS controller or memory module, volatile memory and the real-time clock need a small, continuous supply to keep their contents. While the module is powered from the system supply, a charging circuit on the module keeps the Ni-MH cells topped up. When the main supply is lost, for example during a planned shutdown, a power-supply fault or a site outage, the pack takes over and feeds only the low-current backup circuit. Because the load in backup mode is small, the pack can hold the data for a limited period; the actual backup time depends on the module, the state of charge and the age of the cells, and should be taken from the Yokogawa hardware manual for the installed system.
Ni-MH cells lose capacity gradually with age, temperature and charge cycles. A pack that still shows a normal voltage can have much less usable capacity than when it was new, which is why battery replacement is normally handled as a time-based maintenance task rather than a repair after failure.
Replacement planning
- Record the installation date of each pack and plan replacement on the interval given in the Yokogawa maintenance documentation for the system.
- Keep at least one spare pack on site for each critical controller type, so a low-battery alarm can be cleared without waiting for shipment.
- Replace packs with the module powered where the system manual allows it, so that memory contents are not lost during the change.
- After installation, allow the pack to charge fully before relying on it, and confirm that the battery alarm has cleared on the system status display.
- Store spares in their original packaging in a cool, dry place and use older stock first, because Ni-MH cells self-discharge during storage.
Typical Applications in Oman & the GCC
Many oil and gas, petrochemical, power and water plants in Oman and the GCC still run CENTUM CS 1000 and CS 3000 hardware alongside newer systems. On these sites, a failed backup battery is a small part with a large consequence: after a power interruption, lost configuration data can extend a restart and require engineering work to restore the controller. High ambient temperatures in equipment rooms without good cooling also shorten battery life, so the replacement interval deserves attention in hot climates.
Seven Star LLC supplies the Yokogawa S9129FA across Oman and the GCC for planned maintenance campaigns and critical spares holdings. Our team can help confirm the correct part number against the label on your existing pack and the module it is fitted to before you place an order.
Related Products
- Schneider Electric Harmony XALK Control Station Enclosure
- Nuovo Pignone SMO0480707 Spark Plug
- Papts fan
- Schneider Electric Harmony XVB Signal Tower Light
- Cooper Crouse-Hinds GUE Series Explosionproof Junction Box
- Phoenix Contact PSR-SCP-24DC/ESP4/2X1/1X2 Safety Relay (2981020)
See also: Yokogawa S9185FA Battery Pack.
Datasheets & Documents
- Document Yokogawa NiMH Battery Packs (S9548FA, S9129FA) Safety Data Sheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.
Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.
Yokogawa at a glance
| Established | 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki |
|---|---|
| Milestones | Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986 |
| Headquarters | Tokyo, Japan |
| Product families | Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers |
Yokogawa products we list
| Family | Models | Typical use |
|---|---|---|
| Pressure and DP transmitters | EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable | Pressure, level and DP flow measurement in process plants |
| Temperature transmitters | YTA610, YTA710 | RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus |
| Flowmeters | ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 | Water and conductive liquids, mass flow of hydrocarbons, steam and gas |
| Analysers | TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover | Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen |
| Controllers and recorders | UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 | Single-loop control, furnace programs and data recording |
| Control and safety systems | CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 | Spares and expansions for CENTUM DCS, safety systems and STARDOM |
| Battery packs | S9129FA, S9185FA, S9548FA | Memory backup batteries for DCS and controller modules |
The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.
Where Yokogawa products are used
In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.
Ordering Yokogawa products: what we need
Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.
Facts checked against Yokogawa's corporate history, October 2026.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
FAQ
Questions about the Yokogawa S9129FA Backup Battery Pack
Answers from our engineering team on installation, compatibility and integration.
01What is the Yokogawa S9129FA battery used for?
It serves as a backup power source for Yokogawa control systems such as CS1000 and CS3000, preserving memory and logic during power interruptions.
02What type of battery chemistry does it use?
The battery uses Nickel-Metal Hydride (Ni-MH) chemistry, offering stability and durability for industrial backup applications.
03What voltage and capacity does it have?
The S9129FA is listed as a 2.4 V Ni-MH pack. Capacity figures differ between sources, so confirm against the label of the installed pack.
04Is this battery suitable for harsh environments?
Operating temperature and environmental limits are not stated here. Confirm them against the module documentation before ordering.
05How do I request a quotation for Yokogawa S9129FA Backup Battery Pack?
Send the model number, required quantity and delivery location through the quote request form or by email to Seven Star LLC. The sales team replies with availability, lead time and commercial terms for your Oman or GCC project.


















Reviews