Brand: WIKA
WIKA TF35 Threaded Temperature Probe with Plug
Description
WIKA TF35 threaded temperature probe with plug connection
The WIKA TF35 is a compact screw-in temperature probe that measures liquids and gases directly in a fitting, with a short integral thermowell and a connector mounted on top. It is aimed at OEM equipment such as compressors, pumps, mobile machines, refrigeration systems and hydrogen applications, and WIKA gives a measuring range of -50 … +200 °C [-58 … +392 °F]. The standard rating is 50 bar, with special hydrogen versions listed up to 1,050 bar. Seven Star LLC supplies the TF35 in Oman and the GCC as an independent supplier in Muscat; the details below show how to select the element, thread and connector.
Sensor elements available on the TF35
| Element | Range |
|---|---|
| Pt1000, class F 0.3 per IEC/EN 60751 | -50 … +200 °C |
| Pt100, class F 0.3 per IEC/EN 60751 | -50 … +200 °C |
| PTC-2000 | -50 … +150 °C |
| NTC 10 kΩ, B(25/85) = 3,976 | -30 … +130 °C |
| NTC 5 kΩ, B(25/85) = 3,976 | -30 … +130 °C |
| NTC 2.5 kΩ, B(20/85) = 3,541 | -30 … +130 °C |
| NTC 2.252 kΩ, B(25/85) = 3,974 | -30 … +130 °C |
Other elements can be supplied on request. Platinum elements follow the IEC standard and have the best stability; NTC and PTC parts are standard for control units but are not interchangeable between suppliers, so match the element to the evaluation electronics.
TF35 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | WIKA / TF35 (data sheet TE 67.10) |
| Type | Threaded temperature probe with integrated thermowell and plug connection |
| Measuring range | -50 … +200 °C [-58 … +392 °F] depending on element |
| Connection method | 2-wire |
| Thermowell diameter | 4 mm [0.16 in] standard; others on request |
| Insertion length | 25 mm [0.98 in]; others on request |
| Mounting thread | G¼ B, G⅛ B, G½ B, M14 x 1.5, ¼ NPT, ½ NPT, 7/16-20 UNF SAE O-ring boss (FPM/FKM) |
| Wetted material | Brass, or stainless steel 1.4404 / 316L for hydrogen applications |
| Operating pressure | Up to 50 bar [725 psi]; hydrogen versions up to 1,050 bar [15,229 psi] |
| Response time t0.5 | Brass about 2.2 s; stainless steel about 2.5 s (for 6 mm diameter) |
| Lead resistance effect | Pt100 about 0.42 °C per metre with 0.22 mm² copper (2-wire) |
| Vibration | Very high vibration resistance |
| Connectors | AMP Junior Power Timer, FASTON 6.3 x 0.8 mm, DEUTSCH DT04-2P, M12 x 1, EN 175301-803 |
Connector, ingress protection and ambient limits
| Connector | Ingress protection (when mated) | Ambient range |
|---|---|---|
| AMP Junior Power Timer | IP66, IP67 | -40 … +130 °C |
| FASTON blade 6.3 x 0.8 mm | IP52 | -40 … +130 °C |
| DEUTSCH DT04-2P | IP66, IP67, IP69K | -40 … +130 °C |
| Circular M12 x 1 | IP66, IP67 | -40 … +90 °C |
| Rectangular EN 175301-803 | IP65 | -40 … +100 °C |
The stated protection class applies only when the matching connector with the same rating is fitted, and the mating connectors are not included with the sensor. Keep the connector temperature inside the table: the short insertion length means a hot medium can raise the connector temperature above its limit, so check the stack at your operating point.
Using the TF35 in hydrogen service
The stainless steel 1.4404 / 316L wetted version is the one the datasheet links to hydrogen applications, with pressure ratings up to 1,050 bar for special versions. Confirm the exact pressure and material with us before ordering, since hydrogen fittings are specified by the end user’s standard.
TF35 compared with the TF37
The TF35 has a directly mounted plug, which gives quick installation and good shock behaviour. The TF37 separates the electrical connection from the measuring point with a cable, which suits hot media where an integral connector would overheat. Choose the TF35 when the medium is below the connector limit and the machine has a mating plug already.
Installation and maintenance
- Choose the sealing method for the thread: copper or fibre washers for G threads, O-ring for UNF SAE, thread sealant for NPT
- Do not exceed the tightening torque of the fitting and avoid damaging the thermowell
- Fit the mating connector with the correct cable and keep a drip loop
- For a 2-wire Pt100, allow for lead resistance in the control unit, or use Pt1000 to reduce it
- Replace the probe rather than repairing it, since it is a sealed unit
Applications in Oman and the GCC
The datasheet lists compressors and pumps, mobile working machines, refrigeration technology and hydrogen applications. In the region this means packaged air compressors, lube-oil and coolant circuits on pumps and engines, mobile plant for construction and mining, chillers and cold storage, and emerging hydrogen test and fuelling systems. Engine and compressor rooms are hot and dusty, so choosing a sealed connector with IP67 or higher helps.
TF35 ordering checklist
- Element: Pt100, Pt1000, PTC or NTC with resistance value
- Thread type and size, and sealing method
- Thermowell diameter and insertion length
- Wetted material: brass or stainless steel
- Connector type and mating connector
- Operating pressure and medium
Practical points when specifying the TF35
Because the TF35 is sold mainly into OEM and machine designs, most problems arise from small mismatches rather than from the sensor itself. Check the thread standard against the port in your manifold (G, NPT, metric M14 x 1.5 and the 7/16-20 UNF SAE port are all offered), choose the seal that matches that port, and confirm that the 25 mm insertion length reaches into the flow rather than sitting in the boss. Match the electrical side too: the controller input decides whether you need a Pt100, a Pt1000, a PTC or one of the NTC values, and the harness decides which of the five connector styles is needed.
Finally, think about service. The probe is a sealed unit with a fixed connector, so a failed probe is replaced as a whole. Keep a few spares of the exact thread, element and connector combination, and record the order details on the machine documentation so that a replacement can be matched from the label.
Information to send with an RFQ
Send the thread, element type, connector, medium, pressure, temperature and annual quantity so we can confirm the configuration.
Documents and quotation
The WIKA data sheet TE 67.10 for the TF35 is attached on this page. Send us the specification and quantity for a quotation from Muscat as an independent supplier.
Other Models in the Wika Tf3x Range
Seven Star LLC supplies models from the Wika Tf3x range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| WIKA TF35 Threaded Temperature Probe with Plug | Temperature Instrumentation | You are viewing this model |
| WIKA TF37 Threaded Temperature Probe with Cable | Temperature Instrumentation | View details |
Datasheets & Documents
- Datasheet WIKA TF35 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
WIKA is the German manufacturer of pressure, temperature, level and flow instruments, best known for its pressure gauges. Alexander Wiegand and Philipp Kachel founded it on 2 January 1946 in Klingenberg am Main, Bavaria. The name comes from the first two letters of their surnames. WIKA is still run by the Wiegand family and is headquartered in Klingenberg.
Seven Star LLC is an independent supplier in Muscat. We list WIKA pressure gauges, diaphragm seals, transmitters, switches, thermometers and thermowells, and supply them to plants, contractors and panel builders in Oman and the GCC by model and order code.
WIKA company profile
| Established | 2 January 1946, Klingenberg am Main, Germany, by Alexander Wiegand and Philipp Kachel |
|---|---|
| First products | Mechanical pressure and temperature gauges |
| Ownership | Family-owned; managed by Alexander Wiegand, grandson of the founder, since 1996 |
| Product families | Pressure gauges, diaphragm seals, pressure transmitters and switches, thermometers, RTDs, thermocouples, thermowells, calibration equipment, level and flow instruments |
Milestones
- 1946: Alexander Wiegand and Philipp Kachel found the company in Klingenberg am Main on 2 January; pressure gauge production starts at the end of the year. The name WIKA comes from the first letters of their surnames.
- 1951: Konrad Wiegand, the founder's son, takes over management.
- 1967: Ursula Wiegand leads the company after her husband's death.
- 1986: The company is reunited with the Kachel thermometer factory, which Philipp Kachel had set up after leaving in 1956.
- 1994: Certification to DIN ISO 9001.
- 1996: Alexander Wiegand, the founder's grandson, becomes head of the company.
WIKA products we list
| Family | Models | Typical use |
|---|---|---|
| Bourdon tube pressure gauges | 111.10, 111.12, 212.20, 213.53, 232.50, 233.50, 232.30/233.30 safety pattern | HVAC and utilities (111 series) to process plants (23x series in stainless steel) |
| Diaphragm and differential pressure gauges | 432.50, 732.51, 700.01, DPGT43 | Low pressures, viscous or dirty media, and filter differential pressure |
| Diaphragm seals | 990.10, 990.27 | Separating the gauge from corrosive, hot or clogging media |
| Transmitters, switches and test gauges | A-10, UPT-20, PSM01, CPG1500 | 4-20 mA pressure signals, switching, and precision calibration checks |
| Thermometers | TG54, Model 55, A52, 73 gas-actuated | Local temperature indication on pipes, vessels and HVAC |
| Temperature sensors and thermowells | TR10, TR12-B, TR33, TC10-B, TW10 flanged, TW15 threaded | RTD and thermocouple measurement in process lines |
The WIKA model number tells you the build. In 232.50, the first digit 2 means stainless steel wetted parts, the second digit 3 means a liquid-fillable case, and ".50" is the case style. The 111 series uses copper alloy wetted parts and suits water and air. Where the medium is corrosive, very hot or would block the gauge, a diaphragm seal such as the 990.27 keeps it away from the Bourdon tube. For temperature, a thermowell like the TW10 lets you remove the sensor without opening the process.
Where WIKA instruments are used
In Oman and the GCC, WIKA gauges, transmitters and thermometers are used in oil and gas, refining and petrochemical plants, power and desalination, water networks, district cooling and HVAC, and on skids and machines from OEMs.
Ordering WIKA instruments: what we need
Send the model, dial size (for example 63, 100 or 160 mm), range and unit, connection size and position (lower or back mount), accuracy class and whether liquid filling is needed. For diaphragm seals and thermowells, add the process connection, materials and insertion length.
Facts checked against WIKA company history, October 2026.
Browse WIKA products by category: Pressure Instrumentation, Temperature Instrumentation.
FAQ
Questions about the WIKA TF35 Threaded Temperature Probe with Plug
Answers from our engineering team on installation, compatibility and integration.
01What temperature range does the TF35 cover?
The measuring range is -50 to +200 degrees C with platinum elements. PTC elements go to +150 degrees C and NTC elements to +130 degrees C.
02What pressure is it rated for?
As standard up to 50 bar. Special versions for hydrogen applications are listed up to 1,050 bar.
03Which connectors are available?
AMP Junior Power Timer, FASTON blade terminal, DEUTSCH DT04-2P, M12 x 1 circular and EN 175301-803 rectangular connectors.
04What is the response time?
The datasheet lists t0.5 of about 2.2 seconds for a brass thermowell and 2.5 seconds for stainless steel, for a 6 mm diameter.
05Is the mating connector included?
No, mating connectors are not included and are available on request as accessories.