Brand: Endress+Hauser (E & H)
Endress+Hauser TMS01 iTHERM MultiSens Flex Multipoint
Description
Endress+Hauser TMS01 iTHERM MultiSens Flex multipoint thermometer
The TMS01 is a flanged iTHERM MultiSens Flex multipoint thermometer with flexible sensors for three-dimensional temperature profiling in vessels, reactors and tanks. Many individual metal-sheathed RTD or thermocouple elements pass through one flange, and each can be placed at its own depth and position. The manufacturer also offers it for linear installation in existing thermowells, which makes it a retrofit option when a reactor already has thermowells in place and only the measuring bundle is to be replaced.
Seven Star LLC, an independent supplier in Muscat, handles TMS01 enquiries for refinery, petrochemical and fertiliser customers in Oman and the GCC. Each unit is engineered to the nozzle and layout, so the useful starting point is a drawing of the vessel and a list of the measuring points.
TMS01 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Endress+Hauser / TMS01 (iTHERM MultiSens Flex, flanged) |
| Product type | Direct-contact RTD/TC multipoint thermometer for 3D profiling |
| RTD ranges | Wire-wound –200 to +600 °C; thin-film 6 mm –50 to +400 °C; thin-film 3 mm –50 to +250 °C; StrongSens 6 mm –50 to +500 °C |
| Thermocouple ranges | Type J –40 to +720 °C; type K –40 to +1 150 °C; type N –40 to +1 100 °C |
| Process temperature | Up to +1 150 °C, depending on configuration |
| Process pressure | 0 to 100 bar (1 450 psi) |
| Response, 3 mm MI cable RTD | t50 2 s, t90 5 s |
| Response, 4.8 mm MI cable RTD | t50 3.5 s, t90 9 s |
| Response, StrongSens 6 mm | t50 below 5.5 s, t90 below 16 s |
| Response, grounded 2 or 3 mm thermocouple | t50 0.8 s, t90 2 s |
| Vibration | RTD 3 g at 10 to 500 Hz; StrongSens up to 60 g; thermocouple 4 g at 2 to 150 Hz |
| Flange, ASME | 1 1/2 to 8 in; 150#, 300#, 400#, 600#; 316, 316L, 304, 304L, 316Ti, 321, 347 |
| Flange, EN | DN40 to DN200; PN10 to PN100 |
| Maximum immersion length | Up to 30 000 mm on request |
| Typical weight | About 40 kg for 12 inserts, 3 in flange, medium junction box |
Values apply to inserts in direct process contact; if thermowells are used, the manufacturer asks for a separate response-time assessment.
What a TMS01 is made of
The TMS01 is modular. Single-point inserts consist of a sheathed element, extension cable and bushing, and can be replaced by releasing the compression fitting on the flange. Multi-point inserts use several independent thermocouple cables in one probe, each sealed with potting and an extension cable, giving a double-sealed design known as ProfileSens. Beyond the inserts there are the flange (with eyebolts), a hinged-cover junction box, a neck that can be a modular support frame or a tube extension, and accessories such as clips, weld-on plates, sealing sleeves, centering stars and labels for point identification. Where extra protection is needed, individual thermowells can be welded to the flange.
Reading the profile: how TMS01 sensors measure
Pt100 elements follow IEC 60751 and measure by a change in platinum resistance; thermocouples generate a voltage proportional to the temperature difference between hot and cold junction. When thermocouples are used, an iTEMP head transmitter provides the reference junction with ±1 K accuracy. Sensor-by-sensor data lets operators see radial and axial gradients and spot hot streaks developing in a bed. Accuracy follows IEC 60584 class 2 for thermocouples as standard, and thin-film or wire-wound Pt100 in IEC class A or AA options are listed.
Related parts: TMS02, TMS11 and spares
Customers choosing a TMS01 usually compare it with the TMS02, which shares the MultiSens Flex concept but is built with a diagnostic chamber and a 200 bar rating, and with the TMS11, which places a straight sensor array in a primary thermowell. Replacement single-point inserts use standard roots such as TSC310 and TST310. Head transmitters with HART, PROFIBUS PA, FOUNDATION Fieldbus or PROFINET output fit in the junction box, and the manufacturer lists SIL functional safety among the available certifications.
TMS01 selection and ordering checklist
- Vessel or reactor nozzle: standard, size, rating, facing and material.
- Whether the unit goes onto a flange directly or into existing thermowells.
- Number of points, layout (linear or 3D) and individual sensor lengths.
- Sensor technology: thermocouple J, K or N, or Pt100 wire-wound, thin-film or StrongSens.
- Single-point or multi-point (ProfileSens) inserts.
- Process temperature and pressure against the 100 bar family limit.
- Neck design (support frame or tube) and junction-box size, material and rating.
- Transmitters or terminals, communication protocol and hazardous-area class.
Installing and servicing a TMS01
Handle the device by the eyebolt only; a representative 12-sensor, 3 in flange build weighs around 40 kg. Do not loosen any threaded part of the process connection while the process is in operation. Calibration of single sensors can be done at the factory before assembly or on site with the service team’s help. For multipoint cable inserts, the manufacturer points to its separate ProfileSens documentation. During commissioning, confirm that each tagged channel reads the correct physical position, and photograph the wiring before closing the junction box. When a sensor drifts or fails, the single-point design lets that element be replaced without discarding the whole assembly.
Where the TMS01 is used in Oman and the GCC
The manufacturer lists olefins, ethylene, propylene, aromatics, benzene, nitrogen-based inorganics, ammonia, urea, NGL production, distillation and hydrogenation among its process applications. In the Gulf that means steam crackers, aromatics units, fertiliser plants and gas-liquids processing. Hot ambient conditions and dust call for tightly sealed junction boxes, and the ability to use an existing thermowell is useful on older reactors where re-welding a nozzle is not welcome.
TMS01 sensor types compared
| Sensor | Range | Best for |
|---|---|---|
| Pt100 wire-wound | –200 to +600 °C | Wide range, stable curve |
| Pt100 thin-film 6 mm | –50 to +400 °C | General duty |
| Pt100 thin-film 3 mm | –50 to +250 °C | Smaller bores, faster |
| Pt100 StrongSens 6 mm | –50 to +500 °C | High vibration |
| Thermocouple K | –40 to +1 150 °C | Highest temperature |
| Thermocouple N | –40 to +1 100 °C | Stable at high temperature |
| Thermocouple J | –40 to +720 °C | Lower range |
Information to send with a TMS01 RFQ
- Nozzle flange data and the vessel or reactor tag.
- Sensor count, type, and individual immersion lengths.
- Design temperature, pressure, fluid and any special corrosion data.
- Existing thermowell details, if the TMS01 is a retrofit.
- Junction-box material, rating and hazardous-area class.
- Transmitter or terminal-block requirement.
- Quantity and delivery location in Oman or the GCC.
Documents and quotation
The official Endress+Hauser technical information for the TMS01 is attached on this page as a PDF. The file is a full technical information document, so allow a moment to open it. It is the reference for ranges, dimensions, materials and process-connection limits, so check your own configuration against it before you commit to a purchase.
Seven Star LLC is an independent supplier based in Muscat and supplies industrial instrumentation in Oman and the GCC. Send us the TMS01 configuration you need, the tag or datasheet line it must match and the delivery location, and we will reply with availability and a quotation.
Other Models in the Eh Itherm Multisens Range
Seven Star LLC supplies models from the Eh Itherm Multisens range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser TMS02 iTHERM MultiSens Flex Multipoint | Temperature Instrumentation | View details |
| Endress+Hauser TMS11 iTHERM MultiSens Linear Multipoint | Temperature Instrumentation | View details |
| Endress+Hauser TMS21 iTHERM MultiSens Slim Multipoint | Temperature Instrumentation | View details |
| Endress+Hauser TMS01 iTHERM MultiSens Flex Multipoint | Temperature Instrumentation | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser TMS01 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser TMS01 iTHERM MultiSens Flex
Answers from our engineering team on installation, compatibility and integration.
01What is the TMS01 multipoint thermometer?
The TMS01 is a flanged iTHERM MultiSens Flex multipoint thermometer with flexible RTD or thermocouple sensors, used for 3D temperature profiling in vessels, reactors and tanks.
02Can the TMS01 be used in existing thermowells?
Yes. The manufacturer describes the TMS01 as suitable for linear installation in existing thermowells, as well as for direct flange mounting.
03What are the TMS01 limits?
The datasheet gives process temperature up to +1150 °C and 0 to 100 bar, depending on configuration. Flange rating, materials and sensor choice set the final figures.
04What does ProfileSens mean in the TMS01?
ProfileSens is the multi-point insert technology: several independent thermocouple cables in one probe, each potting-sealed with its own extension cable, giving a double-sealed design.
05How is the TMS01 different from the TMS02?
Both use flexible sensors. The TMS02 adds a diagnostic chamber and is rated to 200 bar, while the TMS01 is rated to 100 bar and can also work in existing thermowells.


















Reviews