Brand:

WIKA 700.01 Magnetic Piston Differential Pressure Gauge

Description

Overview

The WIKA 700.01 is a compact differential pressure gauge with a magnetic piston, designed to monitor differential pressure even when the line itself runs at high working pressure. WIKA lists filter systems, pump monitoring, cooling circuits and pipeline systems as its main applications, with the gas and air preparation and supply industry as the primary market. The system case is stainless steel, the indicator case is aluminium die-cast, and the standard instrument weighs only about 220 g, so it can hang directly on rigid impulse lines without a heavy support.

Seven Star LLC supplies the WIKA 700.01 and its sister model 700.02 with separating diaphragm to plant operators, OEM skid builders and maintenance contractors in Oman and across the GCC, with engineering support in Muscat. We help customers choose the right differential range, static pressure rating, connection layout and reed contact configuration for each filter or pump.

Measuring Principle

In the WIKA 700.01 the two pressures p1 and p2 act on the plus and minus sides of a measuring chamber that is divided by a pressure-loaded magnetic piston. The difference between the two pressures moves the piston axially against a measuring range spring made of stainless steel 1.4310. An annular magnet fixed to the pointer follows the magnet inside the piston, so every piston position corresponds to a defined pointer position on the dial.

The important consequence, as WIKA explains, is that the measuring system and the indicator are completely separated mechanically, with no shaft passing through the pressure boundary and therefore no leakage path to the outside. In the WIKA 700.01 the small volume flow from the plus side to the minus side is minimised by design and does not interfere with normal processes; for liquids or media with suspended solids WIKA specifies the model 700.02, whose separating diaphragm in NBR prevents any flow between the chambers.

Engineering Design of the WIKA 700.01

The measuring chamber is stainless steel 1.4571 with two G ¼ female connections in-line on the left and right side per EN 837-1, and other female or male threads, lower mount or back mount layouts and a fine filter in the plus connection can be specified. The piston is stainless steel 1.4571 with a hard ferrite magnet. Working pressure ratings of 100, 250 or 400 bar are offered, and overload safety on either side extends to the full maximum working pressure, so a blocked filter or a one-sided pressurisation during start-up will not damage the gauge.

The NS 80 aluminium dial is printed with an outer black bar scale and an inner red psi scale, and a maximum drag pointer is optional. The window is clear non-splintering plastic snapped into the case. Mounting can be by rigid measuring lines, a panel mounting flange (available only on the WIKA 700.01) or an instrument bracket for wall mounting. The system and indicator cases can be exchanged on site, which allows a range change or repair without replacing the complete instrument.

Key Features

The WIKA 700.01 offers the following advantages for differential pressure monitoring.

  • Differential pressure ranges from 0–400 mbar to 0–10 bar suit filter, strainer and pump differential monitoring.
  • Static pressure ratings of 100, 250 or 400 bar allow installation on high-pressure gas and compressed air lines.
  • Overload safety on either side up to the maximum working pressure protects against one-sided pressurisation.
  • The magnetic coupling separates measuring system and indication, eliminating leakage to the outside.
  • Indication accuracy is ±3% of full scale value with increasing differential pressure.
  • Up to two reed contacts, model 851.3 or 851.33, can be retrofitted and adjusted on site between 20 and 80% of full scale.
  • Low weight of approximately 220 g and a compact NS 80 case simplify installation on skids.
  • Ingress protection IP54, ambient temperature 0 to +60 °C and medium temperature up to +100 °C.

Industrial Applications

In Oman the WIKA 700.01 is well suited to compressed air dryer and filter trains, natural gas filter separators and fuel gas skids, instrument air packages, nitrogen generators and blower intake filters, all of which involve clean gas or air. Power stations and desalination plants use the liquid-rated 700.02 variant on cooling water and other liquid filters, and OEMs in Rusayl and Sohar fit them to packaged compressors where a contact signal for filter change is required.

For very low differential pressures in HVAC and clean rooms, the Dwyer Magnehelic 2000 Differential Pressure Gauge is usually the better instrument, and for larger dials with higher accuracy at high static pressure the WIKA 732.51 Stainless Steel Differential Pressure Gauge is an alternative. Where a 4–20 mA signal is needed alongside local indication, the WIKA DPGT43 Differential Pressure Gauge with Output Signal combines both functions. Seven Star LLC supplies the WIKA 700.01 with engineering support, and our team can supply matching manifolds and impulse fittings for installations across Oman and the GCC.

Technical Specifications

The WIKA 700.01 specifications below are taken from WIKA data sheet PM 07.14.

Parameter Specification
Model WIKA 700.01 (700.02 with separating diaphragm)
Nominal size 80 mm
Differential pressure ranges 0–400 mbar to 0–10 bar (700.02: 0–160 mbar to 0–2.5 bar)
Indication accuracy ±3% of full scale value (700.02: ±5%)
Max. working (static) pressure 100, 250 or 400 bar (700.02: 50 or 100 bar)
Overload safety Either side to maximum working pressure
Measuring chamber Stainless steel 1.4571, 2 x G ¼ female, in-line
Pressure element Compression spring, stainless steel 1.4310
Magnetic piston Stainless steel 1.4571 with hard ferrite magnet
Indicator case Aluminium die-casting, black
Dial Aluminium, white; outer bar scale black, inner psi scale red
Ambient temperature 0 to +60 °C
Medium temperature Max. +100 °C
Ingress protection IP54 per IEC/EN 60529
Reed contacts (option) 851.3: 1 change-over, max. 250 V, 1 A, 60 W/VA; 851.33: 2 change-over, max. 30 V, 0.25 A, 3 W/VA
Weight Approx. 220 g (700.02: approx. 500 g)

Installation Guidance

Mount the WIKA 700.01 according to the symbols on the case, with the plus connection to the high-pressure side upstream of the filter and the minus connection downstream. As general practice, fit a three-valve manifold so the gauge can be equalised and isolated during maintenance, and open the equalising valve first during start-up. Choose a range whose full scale is close to the filter change differential recommended by the filter manufacturer, and set any reed contact to that value so the control system receives a timely alarm.

How to Order

To receive a quotation for the WIKA 700.01, tell Seven Star LLC the differential range, static pressure rating, connection layout, mounting method and whether reed contacts or a drag pointer are required. Our Muscat office will check availability and lead time, share the WIKA data sheet PM 07.14 and provide engineering support for your filter and pump monitoring points in Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet WIKA Data Sheet PM 07.14, Models 700.01 and 700.02 (manufacturer datasheet) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

WIKA is the German manufacturer of pressure, temperature, level and flow instruments, best known for its pressure gauges. Alexander Wiegand and Philipp Kachel founded it on 2 January 1946 in Klingenberg am Main, Bavaria. The name comes from the first two letters of their surnames. WIKA is still run by the Wiegand family and is headquartered in Klingenberg.

Seven Star LLC is an independent supplier in Muscat. We list WIKA pressure gauges, diaphragm seals, transmitters, switches, thermometers and thermowells, and supply them to plants, contractors and panel builders in Oman and the GCC by model and order code.

WIKA company profile

Established 2 January 1946, Klingenberg am Main, Germany, by Alexander Wiegand and Philipp Kachel
First products Mechanical pressure and temperature gauges
Ownership Family-owned; managed by Alexander Wiegand, grandson of the founder, since 1996
Product families Pressure gauges, diaphragm seals, pressure transmitters and switches, thermometers, RTDs, thermocouples, thermowells, calibration equipment, level and flow instruments

Milestones

  • 1946: Alexander Wiegand and Philipp Kachel found the company in Klingenberg am Main on 2 January; pressure gauge production starts at the end of the year. The name WIKA comes from the first letters of their surnames.
  • 1951: Konrad Wiegand, the founder's son, takes over management.
  • 1967: Ursula Wiegand leads the company after her husband's death.
  • 1986: The company is reunited with the Kachel thermometer factory, which Philipp Kachel had set up after leaving in 1956.
  • 1994: Certification to DIN ISO 9001.
  • 1996: Alexander Wiegand, the founder's grandson, becomes head of the company.

WIKA products we list

Family Models Typical use
Bourdon tube pressure gauges 111.10, 111.12, 212.20, 213.53, 232.50, 233.50, 232.30/233.30 safety pattern HVAC and utilities (111 series) to process plants (23x series in stainless steel)
Diaphragm and differential pressure gauges 432.50, 732.51, 700.01, DPGT43 Low pressures, viscous or dirty media, and filter differential pressure
Diaphragm seals 990.10, 990.27 Separating the gauge from corrosive, hot or clogging media
Transmitters, switches and test gauges A-10, UPT-20, PSM01, CPG1500 4-20 mA pressure signals, switching, and precision calibration checks
Thermometers TG54, Model 55, A52, 73 gas-actuated Local temperature indication on pipes, vessels and HVAC
Temperature sensors and thermowells TR10, TR12-B, TR33, TC10-B, TW10 flanged, TW15 threaded RTD and thermocouple measurement in process lines

The WIKA model number tells you the build. In 232.50, the first digit 2 means stainless steel wetted parts, the second digit 3 means a liquid-fillable case, and ".50" is the case style. The 111 series uses copper alloy wetted parts and suits water and air. Where the medium is corrosive, very hot or would block the gauge, a diaphragm seal such as the 990.27 keeps it away from the Bourdon tube. For temperature, a thermowell like the TW10 lets you remove the sensor without opening the process.

Where WIKA instruments are used

In Oman and the GCC, WIKA gauges, transmitters and thermometers are used in oil and gas, refining and petrochemical plants, power and desalination, water networks, district cooling and HVAC, and on skids and machines from OEMs.

Ordering WIKA instruments: what we need

Send the model, dial size (for example 63, 100 or 160 mm), range and unit, connection size and position (lower or back mount), accuracy class and whether liquid filling is needed. For diaphragm seals and thermowells, add the process connection, materials and insertion length.

Facts checked against WIKA company history, October 2026.

FAQ

Questions about the WIKA 700.01 Magnetic Piston Differential Pressure

Answers from our engineering team on installation, compatibility and integration.

01How does the WIKA 700.01 measure differential pressure?
The two pressures act on either side of a magnetic piston supported by a measuring range spring. The piston moves with the pressure difference, and an annular magnet on the pointer follows it, so the measuring system and indicator are mechanically separated without any leakage path.
02What ranges and static pressures does the WIKA 700.01 support?
Differential ranges run from 0 to 400 mbar up to 0 to 10 bar, with maximum working pressures of 100, 250 or 400 bar and overload safety on either side up to the maximum working pressure.
03Can I use the WIKA 700.01 on water or liquids?
WIKA recommends the model 700.02 with separating diaphragm for liquid media and media with suspended solids, because the 700.01 allows a small volume flow from the plus to the minus side. The 700.01 is primarily intended for gases and air.
04Can switch contacts be added to the WIKA 700.01?
Yes. Up to two reed contacts, model 851.3 with one change-over contact or 851.33 with two, can be retrofitted and adjusted on site in the range of 20 to 80 percent of full scale.
05Who supplies the WIKA 700.01 in Oman?
Seven Star LLC supplies the WIKA 700.01 and 700.02 in Oman and across the GCC, with engineering support in Muscat for range selection, contacts and manifolds.