Brand: JUMO
JUMO dTRANS O2 01 Two-Wire Dissolved Oxygen Transmitter
Description
Dissolved oxygen measured at the source with a two-wire 4-20 mA loop
The JUMO dTRANS O2 01 (type 202610) is an electrochemical, membrane-covered dissolved-oxygen sensor with the transmitter electronics built into its stainless-steel shaft. It returns an electrically isolated 4 to 20 mA signal proportional to the oxygen content and, from the standard version upwards, a second 4 to 20 mA two-wire signal for the medium temperature measured by a Pt1000. The built-in microprocessor corrects for temperature, atmospheric pressure (500 to 1500 hPa, or entered as height above sea level up to 3000 m) and salinity up to 40 g/kg, so a plant at altitude or in brackish water does not need a separate correction table. Calibration is a safe single-point procedure, and the sensor module is a replaceable item rather than a throwaway probe.
JUMO lists municipal and industrial sewage-treatment plants, drinking-water monitoring, pollution prevention, fresh- and salt-water fish farming and processing plants as the typical fields of use.
Technical specifications
| Parameter | Specification |
|---|---|
| Type | 202610, JUMO dTRANS O2 01 two-wire transmitter for dissolved oxygen (DO) |
| Versions | 202610/80 basic (terminal box); /81 standard (operating unit with display, oxygen + temperature outputs); /82 maximum (AC supply, two relays) |
| Oxygen range | 0 to 2 up to 0 to 50 mg/l, freely programmable; order range code 2000 = 0 to 20 mg/l |
| Units | mg/l or % saturation; display resolution 0.01 mg/l or 0.1 %, 0.1 °C |
| Accuracy | ±1 % of end of range (20 mg/l); display 0.25 % of range; output signal 1 % of range |
| Response time | t90 under 180 s at 25 °C; minimum inflow 5 cm/s |
| Temperature measurement | 0 to 50 °C fixed, Pt1000 class B; temperature compensation 0 to +50 °C |
| Compensation | Atmospheric pressure 500 to 1500 hPa or 0 to 3000 m; salinity 0 to 40 g/kg |
| Output signal | 4 to 20 mA, freely scalable; temperature output fixed 10 to 50 °C (basic) or 0 to 50 °C (standard/maximum) for 4 to 20 mA |
| Supply | Basic and standard: DC 19 to 31 V (24 V nominal); maximum: AC 110 to 240 V (+10/-15 %) or AC/DC 20 to 30 V, approx. 8 VA |
| Burden | Oxygen output (UB – 10 V)/0.02 A; with temperature (UB – 17 V)/0.02 A |
| Sensor housing | Shaft stainless steel 1.4305; sensor head and protective basket PVC; IP68; approx. 700 g; 8 m attached cable (10 or 15 m optional) |
| Terminal box or operating unit | PC housing, IP65, approx. 2 kg, cable length to sensor 8 m |
| Safe pressure | 6 bar maximum at 20 °C; permissible ambient temperature -5 to +50 °C |
| Protection | Coarse and fine lightning protection; EMC to EN 61326 |
Choosing a version and decoding the type code
The type code reads 202610/ extension – output – range – cable length – supply – language. Extension 80 is the basic version with terminal box, 81 the standard version with the operating unit, and 82 the maximum version with relays and an AC-capable supply. Output code 006 is 4 to 20 mA with internal supply, 405 is 4 to 20 mA with external supply and 500 is a Pt1000 resistance output. Range 2000 is 0 to 20 mg/l; cable lengths are 08, 10 or 15 m; supply 23 is AC 110 to 240 V, 25 is AC/DC 20 to 30 V and 28 is DC 19 to 31 V. The last digit selects operator language: 1 German, 2 English, 3 French and 4 Spanish. The manufacturer states that the code is a designation rather than a free modular system, so any combination outside its tables must be released by JUMO. Listed combinations include 202610/80-500-2000-08-28-1 (00391336), 202610/81-405-2000-08-28-2 (00409019) and 202610/82-006-2000-08-23-2 (00406637).
Installation, fittings and spares
The transmitter is designed for flow-through, immersion, suspension or float fittings from the JUMO analysis accessory range. The flow-through angled-seat fitting is PVC, rated +5 to +50 °C and up to 1 bar, with solvent-weld sockets and a DN50 T-piece, so it suits bypass lines in aeration basins and effluent channels. JUMO advises installing the fitting where it can be reached for cleaning, using bypass lines with shut-off valves so the probe can be removed, and having the system designer confirm chemical compatibility of every wetted material. Because the signal is a 4 to 20 mA loop, the output can be read by a PLC or fed to the published JUMO dTRANS AS 02, which the datasheet shows as an indicator/controller with two relays. Spares include a set of two replacement sensor modules (00393329), PC setup program with adapter (00394728), a USB interface cable (00456352), a pipe installation kit and a weather-protection canopy. See the liquid analysis sensors category for related probes.
To select the right version, state the oxygen range in mg/l, the supply available (24 V loop, or mains for the maximum version) and whether the local operating unit with display is required. Sensor module replacement is a normal service step, so the buyer should plan spare modules. Tell us the process temperature, the water salinity and the site altitude, because the transmitter compensates for salinity up to 40 g/kg and for atmospheric pressure, either as a pressure value or as an altitude. The fitting must also be matched to the tank or channel, with a cable length to the sensor of 8 m fixed in the datasheet.
Documents and quotation
The hosted document is JUMO data sheet 202610 (12 pages, English). Check the version, cable length, supply and language before ordering, and remember that membrane-covered sensors need periodic service. Seven Star LLC is an independent supplier in Muscat; send the full type code and the water type and we will quote.
Datasheets & Documents
- Datasheet JUMO dTRANS O2 01 data sheet 202610 (EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
JUMO is the German maker of temperature sensors, process controllers, pressure transmitters and liquid analysis instruments. Moritz Kurt Juchheim founded it in Fulda in 1948 as M. K. Juchheim KG, making glass thermometers with six employees. The name JUMO comes from the founder's name. It is still a family company headquartered in Fulda, and the parent company has been called JUMO GmbH & Co. KG since 2003.
Seven Star LLC is an independent supplier in Muscat. We list JUMO RTD and thermocouple probes, thermowells, transmitters, controllers, recorders and water analysis instruments, and supply them to process plants, OEMs, HVAC contractors and water utilities in Oman and the GCC by type number.
JUMO company profile
| Established | 1948, Fulda, Germany, by Moritz Kurt Juchheim |
|---|---|
| First products | Glass and contact thermometers; platinum glass sensors from 1966 |
| Ownership | Family-owned; renamed JUMO GmbH & Co. KG in 2003 |
| Product families | RTD and thermocouple probes, thermowells, temperature and pressure transmitters, controllers and thermostats, safety temperature limiters, paperless recorders, liquid analysis and flow and level instruments |
Milestones
- 1948: Moritz Kurt Juchheim founds M. K. Juchheim KG in Fulda, making glass thermometers with six employees.
- 1966: Platinum glass temperature sensors are added.
- 2003: The parent company is renamed JUMO GmbH & Co. KG.
JUMO products we list
| Family | Models | Typical use |
|---|---|---|
| RTD and thermocouple probes | 902020, 902030, 902050, 902120, 902006 2xPt100, PROCESStemp, mineral-insulated RTD, 901020 thermocouple, 901210, 902810 hygienic, 902550 surface, 902520 HVAC, MarineTemp | Temperature measurement in pipes, vessels, machines, HVAC and food plants |
| Thermowells and inserts | 909710 thermowells, 909740 measuring inserts | Protecting sensors and replacing them without opening the process |
| Temperature transmitters | dTRANS T01, T03, T04, T05, T06 SIL, T07 HART, T09, T1000 IO-Link, DELOS T switch | Converting sensor signals to 4-20 mA, HART or IO-Link |
| Pressure and level | dTRANS p20, p30, p31 hygienic, p33 Ex, p02 DELTA, MIDAS S05, MIDAS DP10, DELOS S02, MAERA S25, NESOS R20 | Pressure in process, hydraulic and OEM systems; tank and well level |
| Controllers, limiters and recorders | DICON touch, IMAGO 500, dTRON 316, iTRON, cTRON, diraTRON 104, eTRON T, safetyM STB/STW, safetyM TB/TW, LOGOSCREEN 601, mTRON T | Furnace, oven and process control, over-temperature protection and recording |
| Liquid analysis and flow | AQUIS touch S, AQUIS touch P, AQUIS 500 pH, AQUIS 500 CR, dTRANS pH 02, pH electrode, digiLine DO, ecoLine NTU, flowTRANS MAG H20, flowTRANS US W01 | pH, conductivity, oxygen and turbidity in water treatment; liquid flow |
Choosing a temperature sensor starts with the range and accuracy. A Pt100 RTD is accurate and stable from about -200 to 600 °C and is the usual choice in process plants. A thermocouple (type K or J, for example) covers much higher temperatures and responds faster but is less accurate. The wiring also matters: a 3-wire or 4-wire Pt100 connection cancels the resistance of the cable, while a 2-wire connection adds an error that grows with cable length. That is why a head-mounted transmitter is often fitted close to the sensor.
Where JUMO products are used
In Oman and the GCC, JUMO sensors and controllers are used in oil and gas and chemical plants, food and beverage production, plastics and metal heat treatment, HVAC and district cooling, water and wastewater treatment, swimming pools and marine applications.
Ordering JUMO products: what we need
Send the JUMO type number and the full order code from the label (for example 902020/10-...). For probes, add the sensor type (Pt100, Pt1000, type K or J), the number of wires, the insertion length and diameter, and the process connection. For controllers, add the input, outputs and supply voltage.
Facts checked against JUMO's company history, October 2026.
Browse JUMO products by category: Temperature Instrumentation, Pressure Instrumentation, Liquid Analysis Sensors, Controllers & Data Acquisition, Level Transmitter.
Related products
Frequently Asked Questions
An isolated 4 to 20 mA signal for dissolved oxygen, freely scalable, plus a second 4 to 20 mA signal for temperature from the standard version upward.
Temperature, atmospheric pressure (500 to 1500 hPa or height up to 3000 m) and salinity from 0 to 40 g/kg.
Freely programmable from 0 to 2 up to 0 to 50 mg/l; code 2000 means 0 to 20 mg/l.
The sensor body is IP68 with a stainless-steel 1.4305 shaft and PVC head and basket; the terminal box and operating unit are IP65.
Yes. The sensor is modular and a set of two replacement sensor modules is listed as accessory 00393329.