Teledyne CP03030 Standard pH Sensor Cartridge
Description
Overview
The Teledyne CP03030 is a genuine standard pH sensor cartridge engineered for the Teledyne Analytical Instruments SP3 and SP3X Smart Sensor platform, providing the interchangeable glass-electrode measuring element that gives SP3-series pH sensors their fundamental measurement capability. The SP3 sensor platform is designed around a common mechanical and electronic housing that accepts different measurement cartridges, allowing a single sensor body to be reconfigured for pH, ORP, specific ion, or other liquid analytical parameters simply by exchanging the cartridge, which significantly reduces spare parts complexity for plants operating multiple analytical measurement points.
With engineering support in Muscat, Seven Star LLC supplies the Teledyne CP03030 pH cartridge to water and wastewater treatment plants, desalination facilities, and industrial process control systems across Muscat, Sohar, and Salalah, helping instrumentation teams keep SP3-series pH measurement points in continuous, accurate operation.
Operating Principle
The Teledyne CP03030 cartridge uses a glass-membrane electrode to generate a voltage proportional to the hydrogen ion activity of the sample solution, following the standard potentiometric principle used in virtually all industrial pH measurement. A reference electrode inside the same cartridge provides the stable comparison potential needed to convert this raw electrode voltage into a calibrated pH reading, with the SP3X digital variant transmitting the processed measurement directly to the compatible transmitter over a digital communication link rather than a raw analog millivolt signal.
Because the measuring element is fully contained within a replaceable cartridge, technicians can restore full sensor accuracy by swapping in a fresh cartridge rather than replacing the entire sensor body, its mounting hardware, and its cable. This cartridge-based design also standardizes the calibration procedure across the plant, since every CP03030 cartridge in service follows the same two- or three-point buffer calibration routine regardless of which sensor body or installation point it is installed in.
Engineering Design of the Teledyne CP03030
Physically, the Teledyne CP03030 is built as a sealed, factory-calibrated glass-electrode module that threads or clips into the SP3/SP3X sensor housing using Teledyne’s standardized cartridge interface, ensuring consistent electrical contact and mechanical alignment regardless of installation location. The cartridge’s wetted materials are selected for compatibility with typical process and treated water chemistries, resisting fouling and chemical attack across normal industrial pH measurement ranges.
Field replacement is a straightforward, tool-minimal procedure: the sensor is removed from process, the spent cartridge is withdrawn from the sensor body, the new CP03030 cartridge is inserted and seated, and the sensor is calibrated against certified pH 4, 7, and 10 buffer solutions before being returned to service. This modular approach minimizes the time a measurement point is out of service, which is particularly valuable for continuous process control loops that rely on live pH feedback.
Consistent, drift-free pH measurement over long unattended runs depends on integrated temperature compensation, and cartridges in the SP3/SP3X family incorporate a temperature-sensing element alongside the glass and reference electrodes so that the pH reading is automatically corrected for the temperature dependence of electrode slope, rather than requiring a separate in-line RTD and manual compensation at the transmitter. The reference half-cell uses a double-junction design, which slows the rate at which process contaminants can migrate into the reference electrolyte and poison the junction — a common cause of reference drift in single-junction electrodes used in fouling-prone wastewater and dosing applications. On the digital SP3X variant, this temperature-compensated pH value, along with electrode diagnostic information, is communicated directly to the compatible transmitter over the sensor’s digital interface, reducing the analog cable-run noise and grounding issues that can otherwise affect a raw millivolt signal traveling any significant distance across a treatment plant.
Because the glass membrane must remain hydrated to respond correctly, new and spare Teledyne CP03030 cartridges are shipped and stored wet, and a cartridge that has been allowed to dry out during long-term storage should be re-hydrated in buffer or storage solution before being placed into service and calibrated; Seven Star LLC supplies cartridges under proper storage conditions specifically to avoid handing a maintenance team a dried-out spare during an urgent replacement. Typical service life in continuous process duty depends heavily on fouling and chemical exposure at the installation point, and plants running aggressive or high-solids media generally plan for periodic cartridge replacement as a scheduled consumable rather than waiting for an out-of-calibration alarm to force an unplanned shutdown of the measurement loop.
Key Features
The Teledyne CP03030 pH sensor cartridge is engineered to deliver dependable, standardized pH measurement across the SP3/SP3X sensor platform:
- Genuine Teledyne glass-electrode design provides accurate, repeatable pH measurement across standard industrial process ranges.
- Interchangeable cartridge format allows fast restoration of sensor accuracy without full sensor body replacement.
- Compatible with the common SP3/SP3X sensor housing shared across the broader Teledyne liquid analytical sensor family.
- Standardized buffer calibration procedure simplifies technician training and plant-wide maintenance consistency.
- Sealed cartridge construction resists fouling and chemical attack in typical process and treated water chemistries.
- Reduces plant spare parts inventory complexity by sharing a common sensor body across multiple parameters.
- Minimizes measurement point downtime during scheduled and unscheduled sensor maintenance activities.
- Supported by Seven Star LLC’s technical support for water and process treatment plant teams.
Industrial Applications
The Teledyne CP03030 pH sensor cartridge serves any facility relying on SP3/SP3X series pH sensors for continuous process or environmental compliance monitoring. Typical applications include municipal water and wastewater treatment plant pH control ahead of chemical dosing and disinfection stages, desalination pretreatment and post-treatment pH verification, and industrial process plants requiring precise pH control for corrosion management, effluent discharge compliance, or chemical reaction control.
Backed by manufacturer datasheet documentation, Seven Star LLC distributes this pH cartridge to municipal utilities, desalination plant operators, and industrial process control teams across the Sultanate of Oman, Muscat, and the Sohar and Salalah economic zones. Planning replacement of this fast-moving consumable component in advance helps plant operators avoid unplanned pH measurement outages that could otherwise disrupt chemical dosing control loops.
Technical Specifications
The table below summarizes the key specifications relevant to the Teledyne CP03030 standard pH sensor cartridge.
| Parameter | Specification |
|---|---|
| Model | Teledyne CP03030 |
| Description | Cartridge, Standard pH Cartridge |
| Sensor Platform | SP3/SP3X Smart Sensor |
| Measured Parameter | pH |
| Sensing Method | Glass-membrane potentiometric electrode |
| Format | Replaceable cartridge, standardized interface |
| Recommended Calibration | Two- or three-point buffer calibration (pH 4/7/10) |
| Compatible Sensor Bodies | SP3/SP3X common housing family |
Request a Quote for Teledyne CP03030 Standard pH Sensor Cartridge
Seven Star LLC invites water treatment engineers, process control teams, and procurement leads across Oman and the GCC to submit a formal RFQ for the Teledyne CP03030 standard pH sensor cartridge. Working closely with plant engineers in the region, we supply SP3/SP3X sensor consumables on request, provide technical datasheets on request, and connect customers directly with our instrumentation division for calibration and application support. Contact Seven Star LLC today to confirm availability, lead time, and pricing for your pH measurement maintenance program.
Related Products
Datasheets & Documents
- Brochure Teledyne SP3/SP3X Brochure Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Two different product lines sit behind the Teledyne name on this page: process gas analyzers and sensors from Teledyne Analytical Instruments, and fixed gas and flame detectors from Teledyne Gas and Flame Detection, the home of the Detcon name. Seven Star LLC lists Teledyne oxygen and moisture analyzers, analyzer circuit boards, replacement sensors and Detcon detectors, and sources them by part number for plants and utilities in Oman.
Teledyne analyzers, sensors and Detcon detectors listed
The listing is weighted toward spare parts for installed analyzers:
- 3000 series oxygen analyzers, such as the 3000RS, with PCB assemblies for Model 3000 and 3020M units and the P01962 power supply, which replaces the obsolete B70284
- 8800B trace moisture analyzer from the 8800 series
- B71875 InstaTrace oxygen sensor
- Liquid analysis parts: the CP03030 pH sensor cartridge and the S02312 free chlorine sensor
- Fire and gas: the Spyglass SG50-F-IR3 triple IR flame detector, listed here under Teledyne Detcon, and the iTrans 2 fixed gas monitor
Where Teledyne analyzers and Detcon gas detectors are used
Teledyne oxygen analyzers measure trace and percent oxygen in nitrogen, hydrocarbon and inert gas streams, for example on air separation units, blanketing systems and gas pipelines. Trace moisture analyzers serve instrument air and dry gas service. Teledyne Detcon gas detectors and flame detectors are used on wellsites, compressor stations, tank farms and water treatment plants in the GCC, wired to a controller or the plant safety system.
Ordering Teledyne parts: what we need
Teledyne Analytical Instruments parts are identified by a letter and number code, such as C70043A or B71875, and by the analyzer model and serial number. Send all of them. Oxygen sensors are selected by class for the background gas and range, so name the sample gas composition and the analyzer model. For a Teledyne Detcon gas detector or flame detector, send the model and full part number from the label, the target gas and range, output, and the area approval required. We check each code against the manufacturer's documentation and propose the listed replacement when a part has been superseded.
Browse Teledyne (Detcon) products by category: Gas Analyzer Accessories, Fire & Gas Detector, Liquid Analysis Sensors, Gas Analyzer Systems.
Related products
Frequently Asked Questions
The CP03030 is designed for the SP3 and SP3X Smart Sensor common housing family, allowing plants to convert a shared sensor body to pH measurement by installing this cartridge in place of another parameter cartridge.
The cartridge is calibrated using a standard two- or three-point buffer procedure with certified pH 4, 7, and 10 buffer solutions, following the same routine used across all SP3/SP3X pH sensor installations.
The cartridge format allows technicians to restore full sensor accuracy by swapping only the measuring element, without replacing the sensor body, mounting hardware, or cable, reducing both cost and measurement point downtime.
Common applications include municipal water and wastewater treatment pH control, desalination pretreatment and post-treatment monitoring, and industrial process plants requiring precise pH control for corrosion management or discharge compliance.
Yes, Seven Star LLC is an experienced supplier of Teledyne (Detcon) analytical and water treatment products across the Sultanate of Oman and the GCC.

Reviews